Page 141
Code 93 <Default All Code 93 Settings>
Code 93
*On
Off
6 - 11
Page 142
Code 93, continued Code 93 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 0-80. Defaults are Minimum = 0, Maximum = 64. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again
Minimum
Maximum
6 - 12
Page 143
Interleaved 2 of 5 <Default All Interleaved 2 of 5 Settings>
Interleaved 2 of 5
*On
Off
6 - 13
Page 144
Interleaved 2 of 5, continued Interleaved 2 of 5 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 2-80. Defaults are Minimum = 4, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again
Minimum
Maximum
6 - 14
Page 145
Interleaved 2 of 5, continued Check Digit A modulo 10 check digit may be encoded in Interleaved 2 or 5. Since the symbology does not provide any means to indicate whether the check digit was encoded, the reader cannot autodiscriminate. Therefore, the reader must be configured if it is to perform check digit validation. Refer to AIM Uniform Symbology Specification Interleaved 2 of 5 for more information.
*No Check Digit Encoded
Validate and Transmit Check Digit
Validate, but Don’t Transmit Digit
6 - 15
Page 146
Code 2 of 5 <Default All Code 2 of 5 Settings>
Code 2 of 5
*On
Off
6 - 16
Page 147
Code 2 of 5, continued Code 2 of 5 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 0-80. Defaults are Minimum = 4, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 17
Page 148
Matrix 2 of 5 <Default All Matrix 2 of 5 Settings>
Matrix 2 of 5
*On
Off
6 - 18
Page 149
Matrix 2 of 5, continued Matrix 2 of 5 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-80. Defaults are Minimum = 4, Maximum = 80. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.
Minimum
Maximum
6 - 19
Page 150
Code 11 <Default All Code 11 Settings>
Code 11
*On
Off
Code 11 Check Digits Required
*2 Check Digits
1 Check Digit
6 - 20