The text of a manual · part 15 of 26
Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser: Symbology Menu, pages 131 to 140
Pages 131 to 140 of 232, from Cordless Scanning System, System Manual: SCANTEAM 2070 Base, IMAGETEAM 3870/75 Linear Imager, SCANTEAM 5770 Laser
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST2070, HHP ST3870 and HHP ST5770
Page 131
6
Symbology Menu
Introduction Use this section to program the cordless system for industrial, retail, and stacked symbology selections. This programming section contains the following menu selections: Codabar
Telepen
Code 39
China Post Code
Code 93
Reduced Space Symbology (RSS)
Interleaved 2 of 5
PDF417
Code 2 of 5
MicroPDF417
Matrix 2 of 5
EAN•UCC Composite Symbology
Code 11
EAN
Code 128
UPC
Programming Tip: If a symbology will not be used, we recommend turning it off to maximize decoding speed and security.
6-1
Page 132
Codabar <Default All Codabar Settings>
Codabar
*On
Off
Start/Stop Characters
Transmit
*Don’t Transmit
6-2
Page 133
Codabar, continued Codabar Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 2-60. Defaults are Minimum = 4, Maximum = 60. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again
Minimum
Maximum
6-3
Page 134
Codabar, continued Codabar Check Character A modulo 16 check character may be encoded in Codabar. Since the symbology does not provide any means to indicate whether the check character was encoded, the reader cannot autodiscriminate. Therefore, the reader must be configured if it is to perform check character validation. Refer to AIM Uniform Symbology Specification Codabar for more information.
*No Check Character Encoded
Validate and Transmit Check Character
Validate, but Don’t Transmit Check Character
Concatenation Codabar supports symbol concatenation. When you turn concatenation on, the reader will look for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Character Start
Stop
Start
Stop
Codabar A12D
D34A
Select Require to prevent the reader from decoding a lone Codabar symbol.
6-4
Page 135
Codabar, continued Concatenation
Concatenation Not Allowed
*Concatenation Allowed, But
Not Required catenation Required
Co nceatenation nequir
Page 136
Code 39 <Default All Code 39 Settings>
Code 39
*On
Off
Start/Stop Characters
Transmit
*Don’t Transmit
6-6
Page 137
Code 39, continued Code 39 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 0-48. Defaults are Minimum = 0, Maximum = 48. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again
Minimum
Maximum
6-7
Page 138
Code 39, continued Check Character A modulo 43 check character may be encoded in Code 39. Since the symbology does not provide any means to indicate whether the check character was encoded, the reader cannot autodiscriminate. Therefore, the reader must be configured if it is to perform check character validation. Refer to AIM Uniform Symbology Specification Code 39 for more information.
*No Check Character Encoded
Validate and Transmit Check Character
Validate, but Don’t Transmit Check Character
6-8
Page 139
Code 39, continued Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = On. NUL %U
DLE $P
SP
SPACE 0
0
@
%V
P
P
‘
W p
+P
SOH $A
DC1 $Q
!
/A
1
1
A
A
Q
Q a
+A q
+Q
STX $B
DC2 $R
“
/B
2
2
B
B
R
R b
+B r
+R
ETX $C
DC3 $S
#
/C
3
3
C
C
S
S c
+C s
+S
EOT $D
DC4 $T
$
/D
4
4
D
D
T
T d
+D t
+T
ENQ $E
NAK $U
%
/E
5
5
E
E
U
U e
+E u
+U
ACK $F
SYN $V
&
/F
6
6
F
F
V
V f
+F v
+V
BEL $G
ETB $W
‘
/G
7
7
G
G
W
W g
+G w
+W
BS
$H
CAN $X
(
/H
8
8
H
H
X
X h
+H x
+X
HT
$I
EM
$Y
)
/I
9
9
I
I
Y
Y i
+I y
+Y
LF
$J
SUB $Z
*
/J
:
/Z
J
J
Z
Z j
+J z
+Z
VT
$K
ESC %A
+
/K
;
%F
K
K
[
%K k
+K
{
%P
FF
$L
FS
%B
,
/L
<
%G L
L
\
%L l
+L
|
%Q
CR
$M
GS
%C
-
-
=
%H
M
M
]
%M m
+M
}
%R
SO
$N
RS
%D
.
.
>
%I
N
N
^
%N n
+N
~
%S
SI
$O
US
%E
/
/O
?
%J
O
O
_
%O o
+O
DEL %T
*On
Off
6-9
Page 140
Code 39, continued Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off.
On
*Off
6 - 10