Page 123

and off the prefix and suffix formatting.

*On

Off

Suffix On/Off

*On

Off

5 - 21

Page 124

Decimal to Hex to ASCII Conversion Chart Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

Dec.

Hex

ASCII

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

SP ! “ # $ % & ‘ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

@ A B C D E F G H l J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

5 - 22

Page 125

Data Formatter Selections The Data Format Editor selections are used to edit scanned data. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned.It is not necessary to use the Data Format Editor. A set of defaults for the data format is already programmed in the scanner. The selections in the following pages are used only if you wish to alter the default settings. Default Data Format setting = none. If you have changed data format settings, and wish to clear all formats and return to the defaults, scan the Default Data Format code on page 5-26.

To Add a Data Format Step 1. Scan the Enter Data Format symbol (page 5-26). Step 2. Primary/Alternate Format Determine if this will be your primary data format, or one of 3 alternate formats. (Alternate formats allow you “single shot” capability to scan one bar code using a different data format. After the one bar code has been read, the scanner reverts to the primary data format. See page 528.) If you are programming the primary format, scan 0. If you are programming an alternate format, scan 1, 2, or 3, depending on the alternate format you are programming. Step 3. Terminal Type Refer to the Supported Terminals Chart (page 2-6) and locate the Terminal ID number for your PC. Scan 3 numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: The wildcard for all terminal types is 099. Step 4. Code I.D. On page 5-20, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart. Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to the Format Editor Commands Chart (page 5-24). Scan the symbols that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format. Step 7. Scan Save to save your entries.

5 - 23

Page 126

Other Programming Selections • Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0. If you are clearing an alternate format, scan 1, 2, or 3, depending on the alternate format you are clearing. Scan the Terminal Type (refer to the Supported Terminals Chart on page 2-6), Code I.D. and the length of the format you want to delete. That length data format for that symbology is deleted and all other formats are unaffected. • Save This exits, saving any Data Format changes. • Discard This exits without saving any Data Format changes.

Data Format Editor Commands Send Commands F1 Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) F2 Send “nn” characters followed by “xx” key or function code, starting from current cursor position. Syntax = F2nnxx (nn stands for the numeric value (00-99) for the number of characters and xx stands for the hex value for an ASCII code. See Decimal to Hex to ASCII Conversion chart, page 5-22.) F3 Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the hex values for ASCII codes, see Decimal to Hex to ASCII Conversion chart, page 5-22.) F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of characters that will not be sent at the end of the message.)

Move Commands F5 Move the cursor ahead “nn” characters from current cursor position. Syntax = F5nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved ahead.) F6 Move the cursor back “nn” characters from current cursor position. Syntax = F6nn (nn stands for the numeric value (00-99) for the number of characters the cursor should be moved back.) F7 Move the cursor to the beginning of the data string. Syntax = F7. EA Move the cursor to the end of the data string. Syntax = EA

5 - 24

Page 127

Search Commands F8 Search ahead for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F8xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) F9 Search back for “xx” character from current cursor position, leaving cursor pointing to “xx” character. Syntax = F9xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) E6 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E6xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) E7 Search back for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E7xx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.)

Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where nn is a count of the number suppress characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) FC Disable suppress filter and clear all suppressed characters. Syntax = FC. EB Toggles the auxiliary port on and off. This command is used when data is normally transmitted out the main port and needs to be temporarily sent out the aux port. The first EB in a format string opens the aux port, temporarily re-directing data transmission out the aux port. Send commands (F1, F2, F3, F4) are then used to transmit data. A second EB command closes the aux port and resumes normal data transmission through the main port. E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2. E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 5-22.) EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC. ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED. EF Inserts a delay of up to 196,605 milliseconds (in multiples of 5). Syntax = EFnnnn where nnnn is a 4-digit hex format count of the number 5 ms delays, up to FFFF.

5 - 25

Page 128

Data Format Editor See page 5-23 through page 5-25 for a description of Data Format selections and commands.

Enter Data Format

Default Data Format

Clear One Data Format

Clear All Data Formats

Save

Discard

Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes).

*Data Formatter On

Data Formatter Off

5 - 26

Page 129

Require Data Format When Data Formatter is required, all input data must conform to an edited format or the base does not transmit the input data to the host device. If this occurs, the scanner triple beeps and the data is discarded.

Data Format Required

*Data Format Not Required

5 - 27

Page 130

Decode Beep Selection Note: Decode Beep mode is active only when the programming selections Host ACK (page 3-6) or Data Format Required (page 5-27) are turned on. When Host Ack Selection is on, the scanner will only beep/blink in response to the Escape commands generated by the host. If you also want the scanner to beep when a bar code has been successfully decoded and successfully communicated to the base, turn the Decode Beep Selection on. When Data Format Required is on, the scanner will only beep if the input data conforms to the edited format or triple beep if it does not meet the format requirements. Should you also want the scanner to beep when a bar code has been successfully read and sent to the host from the base, turn the Decode Beep Selection on.

On

*Off

Alternate Data Formats Alternate formats allow you “single shot” capability to scan one bar code using a different data format than your primary format. When data formats are programmed (see page 5-23), you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. An alternate format is initiated by scanning one of the 3 alternate format bar codes below. The scanner will scan the next bar code, formatting the data with the selected alternate format, then revert immediately to the primary format.

Alternate Data Format 1

Alternate Data Format 2

Alternate Data Format 3

5 - 28