Page 161

PDF417 (IT3870PDF/IT3875PDF only) <Default All PDF417 Settings>

PDF417

*On

Off

6 - 31

Page 162

PDF417 (IT3870PDF/IT3875PDF only), continued PDF417 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum length range = 11000 and Maximum length range = 1-2750. Defaults are Minimum = 1, Maximum = 2750. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.

Minimum

Maximum

6 - 32

Page 163

PDF417 (IT3870PDF/IT3875PDF only), continued Show GLI Blocks Three compaction modes are defined for data that is encoded into a PDF417 symbol. Optionally, a user may devise a new compaction or interpretation method using the Global Label Identifier (GLI) feature of PDF417. This mode is recommended when the host system is capable of interpreting the GLI Block and capable of performing the new interpretation. The GLI Block may occur anywhere in the data, and begins with the escape character ’\’ (ASCII 5C hex). Any natural occurrence of the ’\’ in data is replaced by ’\\’. When this feature is disabled, the GLI Blocks are not transmitted. Default = Don’t Show GLI Blocks.

Show GLI Blocks

*Don’t Show GLI Blocks

6 - 33

Page 164

PDF417 (IT3870PDF/IT3875PDF only), continued Macro PDF417 Macro PDF417 is an optional feature for PDF417 that allows the data from multiple symbols to be combined into a single message. Enabling this feature causes the reader to buffer Macro PDF417 symbols and to assemble them in the correct order, regardless of the order in which the symbols are scanned. When this feature is disabled, the reader transmits the data from each symbol independently, in the order it is scanned. Default = Buffer.

*Buffer

Don’t Buffer

Show Macro Control Blocks Turning on this feature causes the Macro PDF Control Block to be transmitted at the end of the encoded data, except when the reader has successfully buffered and assembled each symbol into a single message. The Control Block is transmitted as defined in AIM Uniform Symbology Specification PDF417 using an escape sequence. The Control Block begins with the escape character ’\’ (ASCII 5C hex), and any natural occurrence of the ’\’ in data is replaced by ’\\’. This mode is recommended when the host system is capable of interpreting the Control Block. When this feature is disabled, the Control Block is not transmitted. Default = Don’t Show Control Blocks.

Show Control Blocks

*Don’t Show Control Blocks

6 - 34

Page 165

PDF417 (IT3870PDF/IT3875PDF only), continued Scan Diagnostics When Scan Diagnostics is turned on, the scanner sends a report instead of the decoded message. Your terminal displays the diagnostic information first, then the data from the scanned code. Default = Off.

On

*Off The following list shows the information that appears for the PDF417 symbology. Note: The higher the percentage of unused error correction (UEC), the easier it should be to read each code. PDF 417: x rows, x cols, xx data & xx chks (ECL = x), UEC = xxx% Rows = Number of rows Cols = Number of columns Data = Number of data words Chks = Number of check words ECL = Error Correction Level UEC = Unused Error Correction

PDF417 Learn Mode This setting tells the scanner to brighten the LED’s when you have an optimal distance between the scanner and the PDF417 code you are attempting to read. Reading distance varies, depending on x-dimension and row height of the symbol. When you turn on the PDF Learn Mode, the IT3870’s light becomes brighter when you are at the best distance for reading the PDF417 code. Default = Off.

On

*Off

6 - 35

Page 166

MicroPDF417 (IT3870PDF/IT3875PDF only) < Default All MicroPDF417 Settings >

MicroPDF417

On

*Off

6 - 36

Page 167

MicroPDF417 (IT3870PDF/IT3875PDF only), continued MicroPDF417 Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum and Maximum lengths = 1-366. Defaults are Minimum = 1, Maximum = 366.

If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.

Minimum

Maximum

6 - 37

Page 168

EAN•UCC Composite Symbology (IT3870PDF/ IT3875PDF only) < Default All EAN•UCC Composite Symbology Settings >

EAN•UCC Composite Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite Symbology. EAN•UCC Composite Symbology allows for the co-existence of symbologies already in use.

On

*Off

Enable UPC/EAN Version Turn on this selection to decode EAN•UCC composite symbols having a UPC or EAN primary component.

On

*Off

6 - 38

Page 169

EAN•UCC Composite Symbology (IT3870PDF/IT3875PDF only), continued EAN•UCC Composite Symbology Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will ignore the symbol and continue scanning. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes below, then scan the appropriate value and Save bar codes on the Programming Chart inside the back cover. Minimum length range = 11000 and Maximum length range = 1-2400. Defaults are Minimum = 1, Maximum = 2400. If you make an error while scanning the digits (before scanning Save), scan Discard on the back cover, scan the Minimum or Maximum bar code, scan the correct digits, and Save again.

Minimum

Maximum

6 - 39

Page 170

EAN/JAN 8 <Default All EAN/JAN 8 Settings>

EAN/JAN 8

*On

Off

6 - 40