Page 71

Command Line Arguments /r

Warm Reset

/c

Cold Reset

SetDeviceInfo SetDeviceInfo sets a unique device name and description for the IK8560/8570. Location

SetDeviceInfo is an executable in the \Program Files\Power Tools folder that creates a Device Name tab window in the “System” Control Panel applet.

Startup

SetDeviceInfo launches automatically after each hard reset. The SetDeviceInfo Program section of the Autorun Configuration File (page 4-1) is enabled by default.

Device Name Tab 1. Tap Start > Settings > ControlPanel.

2. Tap the System icon

.

3. Tap the Device Name tab. The Device Name window appears displaying the default Device name and Description.

4. You can enter a unique Device name and Description in both fields. ActiveSync recognizes the Device name and Description entered here. 5. Tap OK to save.

Default Device Name The Device name in the graphic above breaks down like this: Prefix

Data

IK

000008216

The SetDeviceID configuration file in the \IPSM folder contains these settings.

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

6-3

Page 72

Customizing the Device Name You can make a custom device name for the IK8560/8570 by modifying the SetDeviceInfo.exm file in EZConfig Editor on the PC.

To change a value, click on the data in the Value column. For more information, see Working with Open Configuration Files (page 2-6).

Device Name Restrictions 1. The device name must begin with a letter. 2. The entire device name (the combination of all three key values) cannot exceed 15 characters. You can enter any values you like within these restrictions.

Key Values Prefix

This field must begin with a letter.

Data

The default is “[SERIALNUMBER].” SetDeviceInfo dynamically obtains the IK8560/8570’s serial number. If you want the serial number in a different location in the device name, type [SERIALNUMBER] as the Value in either the Prefix or Suffix keys.

Suffix

The default is “[MODELNUMBER].” SetDeviceID dynamically obtains the IK8560/8570’s model number. If you want the model number in a different location in the device name, type [MODELNUMBER] as the Value in either the Data or Prefix keys.

6-4

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 73

SysInfo SysInfo provides a read-out of important system information including firmware versions, .dll versions, system parameters, as well as network and radio information.

To See System Information 1. Tap Start > Programs > Power Tools. The Power Tools Main Window (see page 1-8) appears.

2. Tap the SysInfo icon once

.

3. SysInfo queries the system, compiles the data and displays it on the SysInfo screen.

You cannot edit information in SysInfo. This information is gathered from the IK8560/8570 and changes only when the IK8560/ 8570’s configuration has changed. To refresh the system information, go to File > Refresh. The system re-compiles system information.

To Save the System Information to a Text File Tap File > Save to File. A file named “Sysinfo.txt” is generated and saved to the IPSM folder. To open the file, tap Start > Programs > File Explorer. Navigate to the IPSM folder. The Sysinfo.txt file appears in the list.

Viewing Options You must copy the file to the host computer to view the file.

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

6-5

Page 74

Sample SysInfo Text Field

Sample Data

This entry specifies the …

Date

04/27/2005

Current date.

Time

16:21:29

Time the SysInfo icon was tapped.

Hardware Revision

1

Hardware revision.

Kernel

8.08 (Oct 04, 2004)

Kernel version.

Service Pack

03

Service pack level.

Boot Loader

8.08 (Oct 04, 2004)

Bootloader version.

Manufacture Date

20040720

Manufacture date.

Model Number

IK8560/8570

Model number.

Part Number

IK8560-000-000

Main board part number.

SYSTEM TIME:

SYSTEM INFO:

Special Part Number

Special part number, if any.

Terminal Serial Number

000008216

IK8560/8570 serial number.

CPLD Version

31205342-005

CPLD firmware version.

Scanner Type

IT4300

Scanner type.

Touch Panel Type

Installed

Type of touch panel.

Display Type

Sharp Color

Type of display.

ProcessorName

PXA255

Name of the CPU.

Architecture

ARM

Processor architecture.

ProcessorLevel

4

Architecture-dependent processor level.

ProcessorRevision

Model A, Pass 6

Architecture-dependent processor revision.

Decoder.dll

2.16

Current DecodeCE.dll API build revision.

MagStripe.dll

1.4

Current MagStripe.dll API build revision.

PROCESSOR INFO:

DLL VERSION INFO:

6-6

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 75

Sample SysInfo Text Field

Sample Data

This entry specifies the …

Matrix Engine

1.97.1.2

Current Matrix engine build revision.

HHPScanInterface.dll

1.15

Current HHPScanInterface.dll API build revision.

Scan Driver

1.100

Current scan driver build revision.

HHPICMediaHW.dll

1.00.01

Current HHPICMediaHW.dll API build revision.

HHPMT9V022HW.dll

1.00.01

Current HHPMT9V022HW.dll api build revision.

ImgApi.dll

2.04.05

Current ImgApi.dll API build revision.

DibCE.dll

2.04.00

Current DibCE.dll API build revision.

OEMInfo

Hand Held Products

Name of the OEM.

PlatformType

Win CE 5.0

Type of platform (CE or PPC)

Hostname test

The logical name assigned to the IK8560/8570.

NumberOfAdapters

2

Number of network adapters installed in the IK8560/ 8570.

1: Mac Address

000000000000

IK8560/8570’s MAC address.

1: IP Address

192.168.55.101

IK8560/8570’s IP address.

Current Mode:

802.11b

Radio mode that is currently enabled.

Modes Supported:

802.11b

/IPSM Contents:

AutoInstall Autorun.exe AutoRun.exm DemosMenu.exm DeviceConfig.exm EZConfigWinCE.exe SetDeviceInfo.exm AutoInstall.exe EZConfigMenu.exm IKWedge.exm PowerTools.exm RegBackup.hhp AutoInstall.exm FrameworkLoaderApp.exe NewDocument.exm

SYSTEM PARAMETERS:

NETWORK INFO:

RADIO INFO:

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Displays the filenames of the files stored in the /IPSM folder.

6-7

Page 76

Sample SysInfo Text Field

Sample Data

This entry specifies the …

/IPSM/AutoInstall/ Contents:

IK8560 Power Tools r1.02.cab IK8560 .NET Install r1.02.CAB ceremote.8560.CAB IK8560 .NET Demos r1.02.CAB

Displays the filenames of the files stored in the /IPSM/ AutoInstall folder.

StoreSize

65773568

Size, in bytes, of the object store.

FreeSize

61070344

Amount of free space in the object store, in bytes.

STORE INFO:

SYSTEM VERSION: MajorVersion

4

MinorVersion

21

BuildNumber

1088

PlatformId

3

CSDVersion

Microsoft’s version and build numbers for the operating system.

Most current service pack installed on the system.

GLOBAL MEMORY STATUS: MemoryLoad

38

Number between 0 and 100 that gives a general idea of current memory utilization. 0 indicates no memory use and 100 indicates full memory use.

TotalPhysical

65888256

Total number of bytes of physical memory.

TotalPageFile

0

Number of bytes of physical memory available.

AvailPageFile

0

Total number of bytes that can be stored in the paging file.

TotalVirtual

33554432

Total number of bytes that can be described in the user mode portion of the virtual address space of the calling process.

AvailVirtual

27721728

Number of bytes of unreserved and uncommitted memory in the user mode portion of the virtual address space of the calling process.

6-8

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 77

7 Registry Power Tools

Overview The registry is the configuration database in all 32-bit versions of Windows that contains settings for the hardware and software, consisting of the SYSTEM.DAT and USER.DAT files. Many settings previously stored in the WIN.ini and SYSTEM.ini files in 16bit Windows (Windows 3.x) are in the registry. The IK8560/8570 contains three Power Tools that enable you manage the registry on your device: 1. RegBackup (page 7-2) 2. RegEdit (page 7-3) 3. RegRestore (page 7-8)

Accessing Registry Power Tools Registry Power Tools are accessed from the Power Tools Main Window (see page 1-8).

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

7-1

Page 78

RegBackup RegBackup backs up the current registry to a RegBackup file stored in the \IPSM folder.

To Backup the Registry To ensure that you are backing up the most current registry, you need to warm boot the IK8560/8570 prior to backing up the registry. 1. Warm boot the IK8560/8570; see Warm Boot on page 6-2.

2. On the Power Tools Main Window (see page 1-8), tap the RegBackup icon once and the following screen appears.

. The registry starts backing up

3. When the backup is complete, a RegBackup file is created and in the \IPSM folder.

Note: By default, the RegBackup.hhp file loads after a cold boot.

Command Line Arguments /h

7-2

Help

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 79

RegEdit RegEdit modifies the device’s registry settings.

To Edit the Registry 1. On the Power Tools Main Window (see page 1-8), tap the RegEdit icon once with a collapsible menu in top half.

. RegEdit opens to a split-pane window

This is the top level of the registry; it cannot be edited, copied, pasted, or renamed. 2. Click the + sign to expand the menu options.

3. Reg Edit offers the following registry categories: Category HKEY_CLASSES_ROOT HKEY_CURRENT_USER HKEY_LOCAL_MACHINE 4. Expand the appropriate menu by clicking on the + sign. 5. Drill-down to the appropriate registry entry. When you click on a registry entry in the top half of the screen, the data appears in the lower half of the screen.

The two columns show the Value Name and the Value Data.

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

7-3

Page 80

6. Double-click on the Value Data. The Edit Value window pops up.

In the Value Data field, type the new value.

7. Press the ENTER or OK key. The new data appears in the list. 8. After all your edits are complete, Warm Boot (see page 6-2) the IK8560/8570.

To Export the Registry You can export the current registry. 1. Tap File > Export. The Save As window appears.

2. Enter a Name. 3. Select a Folder. Selecting None places the file in the My Documents folder. 4. You can save the exported file only as a .reg file Type.

7-4

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide