For the HHP IK8560 and HHP IK8570

Page 61

Symbologies Settings 0=Disabled 1=Enabled IKWedge Entry

Default Enabled/ Disabled Value

Default Value

Telepen

0=Disabled

1,60,0,0,0,0,0,0

Code 16K

0=Disabled

1,160,0,0,0,0,0,0

PosiCode

0=Disabled

4,48,0,0,0,0,0,0

Coupon Code

0=Disabled

0,0,0,0,0,0,0,0

4-CB (4-State Customer Barcode)

1=Enabled

0,0,0,0,0,0,0,0

ID-tag (UPU 4-State)

1=Enabled

0,0,0,0,0,0,0,0

VK (Virtual Key) Mapping Section The virtual key map settings are located in the VKMapping section in the IKWedge configuration file. The virtual key map settings define the virtual key that will be sent to IKWedge for any decoded ASCII character. The settings are in the form: ASCII Key = Virtual Key, ShiftMode Where • ASCII Key is an ASCII value between 0 an 255 (decimal) • Virtual Key is the virtual key to be sent when the specified ASCII key is decoded • ShiftMode can have the following values: • 0=the virtual key is never shifted • 1=the virtual key must be shifted • 2=the virtual key needs to be shifted if Caps Lock is off • 3=the virtual key needs to be shifted if Caps Lock is on For detailed information about the values in this section, see Virtual Key Codes Table on page 5-10.

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

5-9

Page 62

Virtual Key Codes Table The following table shows the symbolic constant names, hexadecimal values, and keyboard equivalents for the virtual-key codes used by the Microsoft Windows CE operating system. The codes are listed in numeric order.

Note: To use these codes in the VKMapping section, the hexadecimal values need to be converted to decimals.

Virtual Key Codes Table Symbolic Constant Name

Decimal Value

Hexadecimal Value

Touch Screen or Keyboard Equivalent

VK_LBUTTON

1

01

Touch screen

VK_CANCEL

3

03

Control-break processing, - 5-7

05-07

Undefined

VK_BACK

8

08

BACKSPACE key

VK_TAB

9

09

TAB key, - 10-11

0A-0B

Undefined

VK_CLEAR

12

0C

CLEAR key

VK_RETURN

13

0D

ENTER key, - 14-15

0E-0F

Undefined

VK_SHIFT

16

10

SHIFT key

VK_CONTROL

17

11

CTRL key

VK_MENU

18

12

ALT key

VK_CAPITAL

20

14

CAPS LOCK key, - 21-25

15-19

Reserved for Kanji systems, - 26

1A

Undefined

VK_CLEAR

12

0C

CLEAR key

VK_RETURN

13

0D

ENTER key, - 14-15

0E-0F

Undefined

VK_SHIFT

16

10

SHIFT key

VK_CONTROL

17

11

CTRL key

VK_MENU

18

12

ALT key

VK_CAPITAL

20

14

CAPS LOCK key

5 - 10

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 63

Virtual Key Codes Table Symbolic Constant Name

Decimal Value

Hexadecimal Value

Touch Screen or Keyboard Equivalent, - 21-25

15-19

Reserved for Kanji systems, - 26

1A

Undefined

VK_ESCAPE

27

1B

ESC key, - 28-31

1C-1F

Reserved for Kanji systems

VK_SPACE

32

20

SPACEBAR key

VK_PRIOR

33

21

PAGE UP key

VK_NEXT

34

22

PAGE DOWN key

VK_END

35

23

END key

VK_HOME

36

24

HOME key

VK_LEFT

37

25

LEFT ARROW key

VK_UP

38

26

UP ARROW key

VK_RIGHT

39

27

RIGHT ARROW key

VK_DOWN

40

28

DOWN ARROW key

VK_SELECT

41

29

SELECT key, - 42

2A

Original equipment manufacturer (OEM)– specific

VK_EXECUTE

43

2B

EXECUTE key

VK_SNAPSHOT

44

2C

PRINT SCREEN key for Windows 3.0 and later

VK_HELP

47

2F

HELP key

VK_0

48

30

0 key

VK_1

49

31

1 key

VK_2

50

32

2 key

VK_3

51

33

3 key

VK_4

52

34

4 key

VK_5

53

35

5 key

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

5 - 11

Page 64

Virtual Key Codes Table Symbolic Constant Name

Decimal Value

Hexadecimal Value

Touch Screen or Keyboard Equivalent

VK_6

54

36

6 key

VK_7

55

37

7 key

VK_8

56

38

8 key

VK_9

57

39

9 key, - 58-64

3A-40

Undefined

VK_A

65

41

A key

VK_B

66

42

B key

VK_C

67

43

C key

VK_D

68

44

D key

VK_E

69

45

E key

VK_F

70

46

F key

VK_G

71

47

G key

VK_H

72

48

H key

VK_I

73

49

I key

VK_J

74

4A

J key

VK_K

75

4B

K key

VK_L

76

4C

L key

VK_M

77

4D

M key

VK_N

78

4E

N key

VK_O

79

4F

O key

VK_P

80

50

P key

VK_Q

81

51

Q key

VK_R

82

52

R key

VK_S

83

53

S key

VK_T

84

54

T key

5 - 12

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 65

Virtual Key Codes Table Symbolic Constant Name

Decimal Value

Hexadecimal Value

Touch Screen or Keyboard Equivalent

VK_U

85

55

U key

VK_V

86

56

V key

VK_W

87

57

W key

VK_X

88

58

X key

VK_Y

89

59

Y key

VK_Z

90

5A

Z key, - 91-95

5B-5F

Undefined

VK_NUMPAD0

96

60

Numeric keypad 0 key

VK_NUMPAD1

97

61

Numeric keypad 1 key

VK_NUMPAD2

98

62

Numeric keypad 2 key

VK_NUMPAD3

99

63

Numeric keypad 3 key

VK_NUMPAD4

100

64

Numeric keypad 4 key

VK_NUMPAD5

101

65

Numeric keypad 5 key

VK_NUMPAD6

102

66

Numeric keypad 6 key

VK_NUMPAD7

103

67

Numeric keypad 7 key

VK_NUMPAD8

104

68

Numeric keypad 8 key

VK_NUMPAD9

105

69

Numeric keypad 9 key

VK_MULTIPLY

106

6A

Asterisk (*) key

VK_ADD

107

6B

Plus sign (+) key

VK_SEPARATOR

108

6C

Separator key

VK_SUBTRACT

109

6D

Minus sign (–) key

VK_DECIMAL

110

6E

Period (.) key

VK_DIVIDE

111

6F

Slash mark (/) key, - 88

88-8F

Unassigned, - 146-185

92-B9

Unassigned

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

5 - 13

Page 66

Virtual Key Codes Table Symbolic Constant Name

Decimal Value

Hexadecimal Value

Touch Screen or Keyboard Equivalent, - 186-192

BA-C0

OEM-specific, - 193-218

C1-DA

Unassigned, - 219-228

DB-E4

OEM-specific, - 229

E5

Unassigned, - 230

E6

OEM-specific, - 231-232

E7-E8

Unassigned, - 233-245

E9-F5

OEM-specific

VK_ATTN

246

F6

VK_CRSEL

247

F7

VK_EXSEL

248

F8

VK_EREOF

249

F9

VK_PLAY

250

FA

VK_ZOOM

251

FB

VK_NONAME

252

FC

VK_PA1

253

FD

VK_EM_CLEAR

254

FE

VK_LWIN

91

5B

VK_RWIN

92

5C

VK_APPS

93

5D

VK_LSHIFT

160

A0

VK_RSHIFT

161

A1

VK_LCONTROL

162

A2

VK_RCONTROL

163

A3

VK_LMENU

164

A4

VK_RMENU

165

A5

5 - 14

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 67

Command Line Arguments /restart

Forces IKWedge to process its configuration file (IKWedge.exm) again, which applies changes immediately. If the SoundConnect (see page 5-3) is set to 1 (enabled), an ascending connect sound is played on restart.

/quit

Shuts down IKWedge.

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

5 - 15

Page 68

5 - 16

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

Page 69

6 Additional Power Tools

Overview This chapter describes the following Power Tools: InstallerCE (page 6-2) Reboot (page 6-2) SetDeviceInfo (page 6-3) SysInfo (page 6-5)

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide

6-1

Page 70

InstallerCE InstallerCE is a utility that saves CAB files after a manual install initiated by double-tapping on the CAB. Normally, when you install a program by double-tapping on its CAB, the CAB file is deleted after installation is complete. InstallerCE preserves the original CAB file in its original location. Location

InstallerCE is located in the \Program Files\Power Tools folder.

To Manually Install a CAB File 1. On the IK8560/8570, open File Explorer. 2. Navigate to the \IPSM\AutoInstall folder. 3. Double-tab on a CAB file. The program begins installing. 4. If the program is already installed, the system will ask you if you want to re-install it. Click Yes. 5. After installation is complete, notice that the CAB file remains in the AutoInstall folder.

Reboot Reboot performs a warm or cold boot from the touch screen. Reboot offers you the option of using the touch screen instead of the hardware button to perform a cold boot.

Warm Boot A warm boot is a soft reset. A soft reset re-boots the device without losing RAM data. You would perform a soft reset when • the IK8560/8570 fails to respond. • after installing software applications that require a re-boot. • after making changes to certain system settings, such as network cards.

Cold Boot A cold boot is a hard reset. A hard reset resets the operating system, restores the IK8560/8570 back to factory defaults, and resets the IK8560/8570. A hard reset erases all of the data stored in RAM memory and all RAM installed applications! Only data and applications stored in \IPSM memory persist.

Rebooting the IK8560/8570 1. Tap Start > Programs > Power Tools. The Power Tools Main Window (see page 1-8) appears.

2. Tap the Reboot icon

. The Reboot screen appears.

To perform a warm boot, tap the Warm Boot button. To perform a cold boot, tap the Cold Boot button. The IK8560/8570 begins booting immediately.

6-2

Image Kiosk™/WinCE 5.0 Power Tools User’s Guide