Page 81
5. Tap OK. The file is saved in the selected location.
Note: Tapping on a .reg file in any folder immediately tries to add the information in that file to the registry. A message appears asking if you want to add the information to the registry. Tap Yes to add the information. Tap No to exit.
To Import Registry Files The file must be loaded on the IK8560/8570 and have a .reg extension. 1. Tap File > Import.
By default, the open function searches for .reg files and displays the search results in the lower half of the window. 2. To import a file into the registry, tap on it twice. The file loads automatically and the RegEdit window appears on the screen.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
7-5
Page 82
File Menu
Menu Item
Description
New
Creates a new Key, String, or DWORD Value.
Import
Imports a registry file; see To Import Registry Files on page 7-5.
Export
Exports the current registry; see To Export the Registry on page 7-4.
Exit
Closes RegEdit.
Edit Menu
Menu Item
Description
Copy
Copies a selected item.
Paste
Pastes a copied item within RegEdit.
7-6
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 83
Menu Item
Description
Rename
Renames a registry entry.
Enter the new name and press the ENTER or OK key. Delete
Deletes a selected registry entry.
Find
Searches for registry entries within a selected section. (Select an item in the top half of the window before tapping Edit > Find.)
Enter the search criteria and tap OK. RegEdit notifies you if the selected section contains data matching the entered criteria. Find Next
Launches another search for the criteria entered in Find.
View Menu
These menu items shift focus between the Keys Panel and the Values Panel.
Registry Edit Options You can also use EZConfig Editor to create registry documents on the PC, create a bar code, then use EZConfig Client to decode the bar code and update the registry on the IK8560/8570. For more information, see • Registry Documents on page 2-14 • Creating Bar Codes on page 2-16 • EZConfig Client on page 2-26
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
7-7
Page 84
RegRestore RegRestore restores the registry to the last backed up registry. When the registry is backed up (see RegBackup on page 7-2), RegBackup creates a RegBackup file in the \IPSM folder.
RegRestore calls, then loads the RegBackup file into the current registry.
To Restore the Registry
On the Power Tools Main Window (see page 1-8), tap the RegRestore icon once registry and the following screen appears.
. The system starts restoring the
When the restore is complete, this screen disappears.
Hard Reset (Cold Boot) By default, the Autorun Configuration File (see page 4-1) launches RegRestore after a hard reset. Therefore, if you want changes made to the registry to persist through a cold boot, back up the registry after your edits are complete; see RegEdit on page 7-3.
Command Line Arguments /r
Reboot after restore.
/q
Quiet, No dialogs
/k
Override kernel version
/s
Override service pack version
/h
Help
7-8
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 85
8 EZMenu
Overview EZMenu formats application windows such as the Power Tools main window (see Power Tools Main Window on page 1-8). EZMenu consists of menu configuration files (special *.exm files) in the \IPSM folder and EZMenu.exe in the \Program Files\Power Tools folder, which applies the menu settings they contain. DemosMenu.exm is an EZMenu.exm file that is included with the Power Tools and demos. *.exm Files
EasyMenu.exe
Running Easy Menu EZMenu runs when you access an application window that has a menu configuration file. EZMenu.exe calls that menu configuration file to format the window.
Default EZMenu Configuration Files The IK8560/8570 ships with a number of menu configuration files in the \IPSM folder: PowerTools.exm
Programs the Power Tools main window (Start > Programs > PowerTools).
EZConfigMenu.exm
Programs the EZConfig Utilities window; see EZConfig Editor on the IK8560/8570 on page 2-22.
DemosMenu.exm
Programs the Demos main window (Start > Programs > Demos)
Default menu configuration files must be located in the \IPSM folder.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
8-1
Page 86
Modifying Menu Configuration Files Menu configuration files can be modified in EZConfig Editor on the PC or the IK8560/8570 For details: See EZConfig Editor on page 2-2. If modified on the PC, the *Menu.exm file must be deployed to the IK8560/8570. See EZConfig Editor on the IK8560/8570 on page 2-22.
Creating Menu Configuration Files Use the Default EZMenu Configuration Files (see page 8-1) to create new menu configuration files. 1. On the PC, navigate to the C:\Program Files\Hand Held Products\Image Kiosk Power Tools\EZConfig Editor folder. 2. Open a sample menu configuration file in EZConfig Editor. 3. Tap File > Save As and save the file with a new name. 4. Modify the file; to see the available values, see Menu Configuration File Sections on page 8-2. 5. Save or transfer the file to the \IPSM folder on the IK8560/8570.
Menu Configuration File Sections Menu configuration files contain of two basic sections: Settings and MenuEntries. Both sections are locked, which means only their Values can be changed.
Settings Section The Settings section defines general EZMenu settings. The keys in this section are locked, which means that only their Values can be changed. Key
Description
Default Value
Available Values
Sig
Identifies this file as a menu file.
EZMenu
These keys are read-only and cannot be changed.
Version
This is the EZMenu version number.
1
EnableDebug
Enables system debugging.
0
0=Disable 1=Enable; an Easymenu.log file is created in the \IPSM folder.
ListViewMode
Determines the default view mode for the window. For details, see View Options on page 1-8.
3
0=Detail 1=List 2=Small Icon 3=Large Icon
Caption
Defines the caption or title displayed in the title bar of the application window.
Variable
User-defined
StartMenu
Enables and disables access to the Start menu from the application window.
Variable
0=Disable Start Menu 1=Enable Start Menu
OK
Toggles the presence of an “X” in the upper, right corner of the application window.
Variable
0=Disable 1=Enable
8-2
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 87
Key
Description
Default Value
Available Values
Menu
Determines which menus appear in the Command bar at the bottom of the window. There are three menus: File, View, and Help. Exit=File menu View=View menu Default=File, View, and Help menus
3
0=No Menus 1=Default Menu + No Exit + No View 2=Default Menu + No Exit 3=Default Menu
The following three parameters determine the icon spacing in all view modes: ListViewIconSpacingY
Determines vertical icon spacing.
65
Spacing is measured in pixels.
ListViewIconSpacingX
Determines horizontal icon spacing.
75
Spacing is measured in pixels.
MaskPassword
Determines whether to mask the optional passwords for the menu entries
1
0=Disable 1=Enable
MenuEntries Section The MenuEntries section determines which programs appear on the application window.
The MenuEntries section is locked, which means that you cannot change its Name or Description; however, its child sections are not locked and can have any name and description. Each child section is a program that launches from the application window and must be at the same level underneath the MenuEntries section. The order of child sections from top to bottom determines the order that the programs appear on the application window.
Child Section Keys The keys in the child sections are locked, which means only their Values can be changed. Key
Description
Required
Available Values
Name
Name to display on the window. The name appears under the icon (if there is an icon).
Required
User-defined
Description
Description to display on the window in Detail view.
Required
User-defined
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
8-3
Page 88
Key
Description
Required
Available Values
CommandLine
Command line to execute when the item is selected on the window. This is the location of the EXE file for the location to launch.
Required
Location of the .EXE. file. Also available: [ADMIN]=Toggles into Administrative mode [EXIT]=Exit menu
CommandArgs
Command line arguments used with the CommandLine parameter.
*Optional
Program-specific
Password
Use this key to password-protect access to the window. If no value is entered, the window is not passwordprotected.
Optional
Enter a password.
HotKey
Hotkey that can be used to launch the menu entry.
Optional
HotKey number
HotKeyModifier
Modifier for the hotkey.
Optional
Global: 16=No Modifier 17=ALT 18=CONTROL 20=SHIFT EZMenu only: 0=No Modifier 1=ALT 2=CONTROL 4=SHIFT
IconFile
The filename of the icon resource file.
Optional
The filename must be an .exe or .dll, NOT an .ico file.
Icon ID
The icon resource identifier contained in the file specified in the IconFile key.
Optional
X=Icon resource identifier
StartupOption
Specifies startup options that must be met for the menu entry to appear on the window.
Optional
See Startup Options on page 8-5.
*Optional keys are not present by default, and must be created manually if desired.
Exit Icon Default EZMenu Configuration Files (see page 8-1) contain a section named Exit as a child section of the MenuEntries section. The Exit section places this icon on the application window, which allows users to exit. If you want users to be able to exit the application window, make sure the Exit section is a child of the MenuEntries section. If you want users to be unable to exit the application window, disable or delete the Exit section.
8-4
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
Page 89
Startup Options Startup Options define the required system parameters for a software application to launch. The following values can be entered for the StartupOption key, wherever it appears: Option Name
The program launches if …
Category
DISABLED
Never, regardless of other startup options specified.
None
COLDBOOT
The IK8560/8570 has performed a cold boot.
WARMBOOT
The IK8560/8570 has performed a warm boot.
Boot type
Multiple options can be specified for each category. Separate multiple options with a comma. To ignore a category, don’t specify any of its options.
Locking Down the Application Window You can program a menu configuration file to block access to the Start menu, OK button, and Command bar menus on the application window. When all of these items are blocked, the user must navigate the IK8560/8570 from the application window. EZMenu carries these settings forward to all windows opened from the application window. This way, access to the Start menu, OK button, and Command bar menus can be blocked globally. 1. Open the menu configuration file in EZConfig Editor. For more information, see Working with Open Configuration Files on page 2-6. 2. In the Settings Section (page 8-2), modify the following keys: Menu=0
(No menus appear in the Command bar.)
3. If you are modifying the file in EZConfig Editor on the IK8560/8570, tap Tools > Launch Associated App. The application window opens displaying your changes. If you are modifying the file in EZConfig Editor on the PC, save, then transfer the file to the IK8560/8570. On the IK8560/ 8570, navigate to the application window to verify your changes.
Note: To remove the Exit icon as well, delete the Exit section; see Exit Icon on page 8-4.
Booting the IK8560/8570 to the Application Window You can program the IK8560/8570 to boot to the application window by modifying the Autorun Configuration File (see page 4-1). 1. In EZConfig Editor, open Autorun.exm. 2. Open the Programs section and enable the EasyMenu section.
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide
8-5
Page 90
3. In the EasyMenu section, modify the Args key to call the .exm file of the application window. This is the path to the menu configuration file; i.e., “\ipsm\***menu.exm.” By default, the Args key calls \ipsm\demosmenu.exm. 4. Warm boot the IK8560/8570 and verify that startup finishes on the application window.
8-6
Image Kiosk™/WinCE 5.0 Power Tools User’s Guide