Page 107

13 Dolphin QuadCharger The Dolphin QuadCharger provides intelligent battery management for NiMH (Nickel Metal Hydride) Dolphin 7400/7450 battery packs. This device fully charges as many as four NiMH batteries in 2.5 hours. Charging slots work independently to control charging and discharging of individual battery packs. The QuadCharger is compatible with all models in the Dolphin® 7400/7450 family of hand held computers. As battery packs charge, the charging circuitry follows a three-step process that senses changes in temperature and voltage and drops to a trickle charge when the packs are fully charged. This feature allows the user to leave batteries in the charger indefinitely, which maintains the batteries at peak capacity without damage. The charger also resets and calibrates battery pack data to accurately show battery status on the Dolphin display. The QuadCharger conditions and calibrates batteries for longer, more consistent performance.

Dolphin QuadCharger Parts and Function Top Panel Power Switch & Power LED

Condition Switch & Condition LED

Status LEDs

Status LEDs

Charging Pocket

Charging Pocket The QuadCharger has four charging pockets for charging and/or conditioning batteries for Dolphin 7400/7450 terminals. Power Switch Press and hold the Power Switch for approximately one second, then release, to turn on the QuadCharger. The Power Switch LED is green when the unit is on. To turn the charger off, press and hold the Power Switch for about two seconds and then release. This feature prevents the unit from being accidently turned off during use or on when not in use. Condition Switch Press the Condition Switch to start a battery conditioning cycle. The orange Condition Switch LED flashes during the conditioning cycle. Status LEDs A Status LED is located above each of the four battery pockets.

13 - 1

Page 108

Rear Panel

Communications Port

Power Supply Connector

Power Supply Connector Use this connector to attach the power supply to the QuadCharger. The universal power supply accepts input voltages between 90-265 volts. Communications Port The communications port is for factory use only in programming the QuadCharger.

Charging Batteries In The QuadCharger Follow these steps to charge batteries in the QuadCharger: 1. Set up the charger for use 2. Supply power 3. Insert batteries CAUTION: Do not attempt to recharge any battery pack in the Dolphin 7400/7450 QuadCharger that is not manufactured by HHP especially for this device. To do so will void your warranty and could damage the Dolphin 7400/7450 QuadCharger.

Setting Up The QuadCharger The Dolphin QuadCharger should be set up on any dry, stable surface. DIN rail slots on the bottom panel allow the charger to be wall or desktop-mounted for easily adapting the unit to your environment. The charger must be connected to a power source for any type of operation.

Supplying Power To The QuadCharger CAUTION: Using a non-HHP power cord voids your warranty and could result in serious damage to the Dolphin QuadCharger’s circuitry. Locate the AC power cord that came with the Dolphin QuadCharger. Plug the cord into the power supply connector on the back of the unit and then plug the power cord into a wall socket. Press and hold the Power Switch for approximately one second, then release, to turn on the Dolphin 7400 QuadCharger. The GREEN power LED will illuminate and the charger will undergo a self-diagnostic test.

Inserting and Removing Battery Packs To insert a battery pack, place the end of the battery without the locking tab into the bottom of the charging pocket and snap the battery into place with a hinging motion. Once the battery is properly seated, the orange status LED for that particular pocket will illuminate. For best results, battery packs should be at room temperature before recharging them; temperature has a marked effect on charging. The recommended temperature range is 50° to 95° F (10° to 35° C). To remove a battery pack, push the locking tab down and pull the battery out from the charging pocket with a hinging motion.

13 - 2

Page 109

LEDs Status LED

Description

Green

Charging is complete and battery is ready for service.

Orange

Battery is being charged at a maximum charge rate

Red

Error was encountered during charge cycle

Servicing The Battery Pack To service battery packs, insert batteries into the charging pockets and press the Condition button. The Condition LED will flash during the conditioning cycle. This starts an automatic process in which batteries are completely discharged and then recharged to full capacity in eight hours. The Condition and Calibrate cycle resets and calibrates battery data so that the user gets longer, more consistent performance from the batteries. HHP recommends that battery packs should be serviced, or calibrated, once a month. Because the Dolphin QuadCharger is accumulating battery pack information during the entire Condition and Calibrate cycle, it is important not to remove the battery until the cycle has been completed and the Condition LED is no longer flashing. Batteries inserted after the “Condition and Calibrate” switch has been depressed will receive a standard charge. The chart below describes the Status LEDs during the Condition and Calibrate cycle: Status of LEDs during Condition and Calibrate Cycle Status LED

Description

Solid Green

Cycle is complete. Battery remains in trickle charge until removed from the charger.

Flashing Orange

Battery is being conditioned

Solid Red

Error was encountered during charge cycle

Storing Batteries To maintain top performance from batteries, follow the guidelines below when storing them: Avoid storing batteries outside of the specified temperature range of -4 to 104° F ( -20 to 40°C) or in extremely high humidity. For prolonged storage, do not keep batteries stored in a charger that is connected to a power source. During long-term storage, battery deactivation may tend to occur which may cause charging to stop early during recharging after storage. This issue can be handled by charging and discharging the battery several times. Also, the first charging after prolonged storage may yield a lower than normal capacity. While this will vary depending on the storage conditions, charging and discharging the battery several times will almost completely restore capacity.

13 - 3

Page 110

Troubleshooting If you encounter problems with your Dolphin QuadCharger, refer to chart below for possible solutions. If problems persist, please contact HHP Technical Support.

Problem

Issue

The “CHARGING” LED does not come on Check the power connections on the Dolphin QuadCharger. Also check to when I insert a battery pack into the Dolphin ensure the POWER switch is ON and the battery pack is properly seated. QuadCharger The red status LED comes on during charging.

Try to charge the battery in one of the other charging pockets. If the red Status LED comes on again, then the problem is associated with the battery pack. If the red status stays with the charging pocket, the problem is associated with the charging circuity.

The red status LED remains on without a battery in the charging pocket.

An error occurred during the self-diagnostic test for that particular charging pocket. Call HHP Product Service and request an RMA. See Chapter 9 for additional warranty and return information.

13 - 4