Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 17

Dolphin 7400/7450 Mobile Computer with Microsoft Pocket PC User's Guide: Dolphin Charging/Communication Cradles

Pages 93 to 106 of 133, from Dolphin 7400/7450 Mobile Computer with Microsoft Pocket PC User's Guide

The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP 7400 and HHP 7450

Page 93

12 Dolphin Charging/Communication Cradles Hub of the System As the hub of your Dolphin system, Dolphin Charging/Communication cradles perform three important functions – power conditioning, communications and storage. Three versions of the charging/communications cradle are available: • IntelliBase for communicating with devices such as printers and modems without integrated IrDA protocol software • IntelliBase+ for communicating with devices without integrated IrDA protocol software and charging and conditioning a spare battery • USB HomeBase for communicating directly with a USB-compatible host computer

Power Conditioning Dolphin charging/communication cradles provide power to the intelligent battery charging system incorporated into Dolphin terminals. The IntelliBase+ has an auxiliary battery well, located on the back of the cradle, allowing users to charge and condition a spare battery.

Ir/IrDA Optical Communications The infrared, or Ir communications port, on the IntelliBase and IntelliBase+ connects with the IrDA port on the Dolphin terminal. With no pins or contacts to break, Ir will work reliably for years. Reliable data communications at speeds of up to 115k baud can be transmitted by the IntelliBase and IntelliBase+; data transmission rates with the USB HomeBase up to 4Mbps are possible but, at this time, are limited to 115 kbps as the Dolphin 7400 does not currently support 4 Mbps data transfer. The IntelliBase and IntelliBase+ infrared connection to the terminal uses IrDA-compliant hardware and software for a reliable connection. Communications between the IntelliBase and other devices occur at half duplex serial mode. Half duplex refers to the transmission of data in just one direction at a time. The USB HomeBase enables direct communication with USB-compatible host computers at rates of up 115 kbps. The USB HomeBase also is IrDA 1.3 compliant. These peripherals cannot be daisy chained but can be networked together using a serial or USB hub.

Convenient Storage Dolphin charging/communication peripherals provide a safe and convenient storage receptacle for your Dolphin terminal.

12 - 1

Page 94

Dolphin Charging/Communication Cradle Parts & Functions Front Panel - IntelliBase/USB HomeBase Terminal Well

DOCK LED

COMM LED

Dolphin Terminal Well Place the Dolphin in this well to communicate with a host device and to charge the Dolphin’s battery. LEDs There are two LEDs on the front panel of the IntelliBase/USB HomeBase.

12 - 2

Page 95

1. Dock LED Turns solid green when the Dolphin terminal is properly seated into the Dolphin IntelliBase. 2. COMM LED Indicates the status of data transfer between the Host Device and the Dolphin Terminal as described below: Comm LED

Description

Red LED

Data is being sent from the Host Device to the Dolphin IntelliBase.

Green LED

Data is being sent from the Dolphin IntelliBase to the Host Device.

Orange LED

Data is being sent at high data rates.

IntelliBase+ Terminal Well

DOCK LED

AUX BATTERY LED

COMM LED

Dolphin Terminal Well Place the Dolphin in this well to communicate with a host device and to charge the Dolphin’s battery. LEDs There are three LEDs on the front panel of the IntelliBase+:

12 - 3

Page 96

1. Dock LED Turns solid green when the Dolphin Terminal is properly seated into the Dolphin IntelliBase. 2. AUX Battery Indicates charging/calibration status of battery as described below: AUX Battery LED

Description

Orange LED

Solid indicates that battery pack is being charged. Flashing indicates battery is being conditioned.

Red LED

Indicates faulty battery.

Green LED

Indicates battery charged and ready for use

3. COMM LED

Indicates the status of data transfer between the Host Device and the Dolphin Terminal as described below:

Comm LED

Description

Red LED

Data is being sent from the Host Device to IntelliBase+.

Green LED

Data is being sent from the IntelliBase+ to the Host Device.

Orange LED

Data is being sent at high data rates.

Back Panel IntelliBase

Power Supply Connector

RS-232 Connector

There is a 5V DC power supply connector and an RS-232 connector: Power supply connector Use this connector to attach a power supply to the IntelliBase. The power supply provides 5V DC input for communications and battery charging. RS-232 Communications Port Use a standard serial cable to connect this port to a host RS-232 device.

12 - 4

Page 97

IntelliBase+ Condition Button

Auxiliary Battery Well

RS-232 Connector Power Supply Connector

Power supply connector Use this connector to attach a power supply to the IntelliBase. The power supply provides 5V DC input for communications and battery charging. RS-232 Communications Port Use a standard serial cable to connect this port to a host RS-232 device. Auxiliary Battery Well Insert a battery into the well to charge or condition and calibrate a battery pack. Condition Button Press and release the button to service the battery in the auxiliary battery well.

12 - 5

Page 98

USB HomeBase USB Connector Power Supply Connector

There is a 5V DC power supply connector and a USB connector: Power supply connector Use this connector to attach a power supply to the USB HomeBase. The power supply provides 5V DC input for communications and battery charging. USB Communications Port Use a USB full-speed detachable cable to connect this downstream device port to an upstream USB Host or Hub. The USB HomeBase is USB 1.3 compliant.

Bottom Panel of IntelliBase A Baud Rate switch used to select the communication baud rate is located on the bottom of the IntelliBase. The Baud Rate Switch on the IntelliBase is a four-position switch. Switch position and the corresponding baud rates are shown in the charts below. The USB HomeBase does not require a baud rate switch.

Baud Rate Switch

12 - 6

Page 99

Baud Rate

Switch 1

Switch 2

Switch 3

Switch 4

115200

OFF

ON

ON

N/A

57600

ON

OFF

OFF

N/A

38400

ON

OFF

ON

N/A

19200

ON

ON

OFF

N/A

9600

ON

ON

ON

N/A

IntelliBase/IntelliBase+ Switch Settings

Powering the Dolphin Terminal Dolphin charging/communication cradles provide power to the intelligent battery charging system incorporated into Dolphin terminals. This charging method protects the battery from being damaged by overcharging. Therefore, Dolphin terminals may be stored indefinitely in the charging/communication cradles without damage to the terminals, battery packs, or peripherals. To charge a Dolphin terminal, follow these steps: 1. Insert a battery pack into the Dolphin terminal. 2. Place the terminal, imager/laser engine window up and the LCD visible, in the terminal well of the cradle. 3. Let it glide down into the well until it stops. 4. Once the Dolphin terminal is properly seated, the Dock LED on the front of the cradle will be solid GREEN.

Charging Additional Battery Packs in the IntelliBase+ The auxiliary battery well located on the back of the IntelliBase+ allows users to charge and condition a spare battery. Charging a Dolphin terminal and a spare battery pack can be done simultaneously as the charging slots work independently to control charging and conditioning of the individual batteries. The IntelliBase+ senses when a battery pack is fully charged and automatically switches to trickle charge to maintain the battery at full capacity indefinitely. To charge a spare battery in the IntelliBase+, insert the end of the battery without the locking tab into the bottom of the auxiliary well opening and snap the battery into place with a hinging motion. Once the battery is inserted, you can use the AUX BATTERY LED to monitor the charging progress.

Deep-Cycling Batteries For maximum battery life, HHP recommends that you deep-cycle (service) the battery twice before initial use and then once a month thereafter. The IntelliBase+ is the only Dolphin charging/communication cradle with deep cycling capabilities. Since the Dolphin IntelliBase and USB HomeBase do not have deep-cycling capabilities, it is recommended that you use the Battery Conditioning Utility software when using those peripherals or use the Dolphin Quad Battery Charger. To deep-cycle a battery using the IntelliBase+, insert the battery into the auxiliary battery well. Then, press and release the Condition button. The deep-cycling process takes 8-12 hours depending on the battery’s capacity or state of charge. See the Battery Management section in Chapter 3 for more information.

Setting Up For Communications The IntelliBase, and IntelliBase+ support RS-232 communications through the RS-232 Communications Port located on the back of the device. The IntelliBase translates the RS-232 signals from the host computer into infrared signals to communicate with the Dolphin Terminal. The IntelliBase RS-232 interface allows the Dolphin terminal to communicate to a personal computer, modem, or any standard RS-232 device using a standard serial cable and communications software. IntelliBase/IntelliBase+

12 - 7

Page 100

The IrDA 1.0 software stack is integrated into the IntelliBase and IntelliBase+ cradles to allow communication between the cradle and devices such as modems or printers that are not IrDA ready or do not communicate with a half duplex serial protocol. This allows any full or half duplex RS-232 device to communicate through the IntelliBase/IntelliBase+ with no IrDA protocol software. See Table 2 for the baud rate switch settings.

Installing The Charging/Communication Cradle To install and use the IntelliBase or IntelliBase+, you need the following equipment: • IntelliBase/IntelliBase+ with power supply • Serial cable Set the Dolphin IntelliBase/IntelliBase+ on a dry, stable surface, such as a desktop near an electrical outlet. Be sure to provide enough workspace with good lighting for the user to view and operate the Dolphin terminal while it is in the IntelliBase. Connecting the Cables Connect the IntelliBase/IntelliBase+ to the host computer or other device by plugging an RS-232 serial cable into the RS-232 Communications Port on the rear of the IntelliBase. The wiring of your cable depends on whether the other device is set up as a DCE (Data Communications Equipment) or DTE (Data Terminal Equipment) device. The IntelliBase Communication Port is configured as a DCE device. To communicate with a DTE device such as a computer, use a standard (or straight-through) RS-232 cable. To communicate with a DCE device, use either a null modem adapter in line with a standard RS-232 cable, or a null-modem serial cable. You can make your own cables by following the pin configuration in the chart below. To do so, you must determine if your host RS-232 device is 9-pin or 25-pin, and whether it is configured as a DCE or DTE device.

IntelliBase /Host Port (DCE)

IBM AT DB9 (DTE)

IBM XT DB25 (DTE)

Modem DB25 (DCE)

Pin / Input Signal 2 / (RD)

2

3

2

3 / (TD)

3

2

3

5 / (SG)

5

7

7

4 / (DTR)

4

20

6

6 / (DSR)

6

6

20

7 / (RTS)

7

4

5

8 / (CTS)

8

5

4

The IntelliBase/IntelliBase+ cannot be daisy-chained. Connect the power supply to the charging/communication cradle. Plug the AC transformer into the Dolphin IntelliBase/ IntelliBase+ 5 Volt DC power supply connector. The AC wall transformer provided can power only one IntelliBase/IntelliBase+. HHP recommends that you leave the Dolphin IntelliBase/IntelliBase+ connected to its power source at all times, so that it is always ready to use. Set the baud rate switch to the communication mode you are going to use. Refer toTable 3 for IntelliBase/IntelliBase+ switch settings.

12 - 8

Page 101

Configuring the Dolphin Terminal for Communications The Dolphin terminal may be configured for communications using the Detectoid Communication Utility as described in Chapter 2 or, manually as described below. To set Communications Properties: 1. Select Start>ActiveSync>Tools>Options. 2. Select the PC Connection tab.

Communications Properties 3. Select the desired option for connecting to the desktop computer. Click OK. 4. Place the Dolphin in the cradle. 5. On the Dolphin 7400/7450 desktop, double-tap on ActiveSync. 6. In the ActiveSync connection settings, add check mark to "Allow serial cable or infrared connection to this COM port" and

12 - 9

Page 102

select "Infrared Port (IR)" for the COM port as shown below.

To configure the Dolphin 7400/7450 terminal for communications, see the previous section on Configuring the Dolphin Terminal.

Setting Up For Communications With The USB HomeBase To use the USB HomeBase, you need the following equipment: • • • •

USB HomeBase with power supply USB Cable CD with USB-IrDA drivers Windows® 98, Windows® Me or Windows® 2000 computer.

Note: The USB HomeBase does not support Windows NT® To install the USB HomeBase, follow these steps:

12 - 10

Page 103

1. Plug in the power supply and connect it to the back of the USB HomeBase. 2. Plug the USB cable into the back of the USB home base. 3. Plug the other end of the USB cable into your PC. At this point, a dialog box appears on your PC instructing you that the system has detected new hardware and it is searching for the HHP USB-IrDA driver. Unless you have previously installed the USB HomeBase, the OS will be unable to find one and the Found New Hardware Wizard screen shown below will display on your PC’s screen.

In the "Locate Drive Files" dialog, check the CD-ROM drives check box and insert the driver CD provided into the CD tray on your PC. There are sub-directories in this directory for each type of Windows OS supported. Select stirusb.sys file in the correct sub-directory for your PC: • w2k - Windows® 2000 • win98 - Windows® 98 • winme - Windows® Me At this point, the hardware is installed and operating. You may need to reset your PC to complete the installation process. You can verify that the USB driver is functioning by watching the COMM LED on the USB home base. It should be flashing red approximately every three seconds. Once the USB HomeBase is installed, you can use ActiveSync to connect to a Dolphin 7400. These instructions assume that ActiveSync v3.1 is installed on your PC.

12 - 11

Page 104

In the ActiveSync connection settings, add check mark to "Allow serial cable or infrared connection to this COM port" and select "Infrared Port (IR)" for the COM port as shown below. Do not check "Allow USB connection with this desktop computer". It has no effect for the USB HomeBase.

To configure the Dolphin 7400/7450 terminal for communications, see the previous section on Configuring the Dolphin Terminal.

Communicating with the Dolphin Terminal To communicate with the Dolphin and any other devices connected to the Dolphin Charging/Communication cradle: 1. Insert the Dolphin into the terminal well of the IntelliBase/USB HomeBase. If the Dolphin is in sleep mode, it will awaken into active state. 2. The DOCK LED on the cradle will illuminate. If the Dolphin does not turn on, or the LED does not light up, make sure that it is properly seated in the terminal well and that the power supply is properly connected to the cradle and plugged into a functioning AC outlet. 3. Start your application on the Dolphin terminal or the host computer. Data can then begin transmitting between the terminal and the devices connected to the Dolphin cradle. When data transfer begins, the COMM LED on the cradle will blink red and green. If the IntelliBase/HomeBase will not communicate with the Dolphin, check the port connections to ensure that the cradle is correctly configured.

12 - 12

Page 105

Mounting the IntelliBase/USB HomeBase The IntelliBase and USB HomeBase may be desk or wall-mounted for convenience and storage. The IntelliBase+ may be deskmounted as long as room is allowed for accessibility to the auxiliary battery well.

Desk Mounting: Dolphin charging/communication cradles have a DIN rail (7.5 X 35 mm) slot on the bottom to allow for secure desk attachment of the unit if desired.

Wall Mounting: The IntelliBase/USB HomeBase also has two DIN rail (7.5 X 35mm) slots on the back to allow for secure wall mounting of the unit if desired. The IntelliBase+ may not be wall-mounted.

12 - 13

Page 106

When using right-angle style RS-232 connector cable, the DIN rails may be mounted directly to the wall. When using standard RS-232 connector cables, it is recommended that the rails be mounted to the wall using a 25mm (1 in.) spacer to allow for appropriate strain relief of the cables.

In either case, after wall mounting, it is recommended that the cables be secured to the DIN rail through use of a wire tie to prevent damage to the IntelliBase/USB HomeBase unit in case accidental or excessive force is applied to the cables.

12 - 14