Page 111
14 Dolphin Mobile Charging/Communication Cradles
As the hub of Dolphin mobile data collection systems, Dolphin Mobile Charging/Communication cradles perform three important functions – power conditioning, communications and storage. Two versions of the mobile charging/communication cradles are available: Dolphin Mobile IntelliBase for use with in-transit data collection applications. Dolphin Mobile Base for use with in-premise warehouse data collection applications.
Power Conditioning The charging/ communication cradles provide power to the Dolphin terminal to enable the terminal to charge its battery.
Ir/IrDA Optical Communications The infrared, or Ir, communications port on the cradles connect with the IrDA port on the Dolphin terminal. With no pins or contacts to break, Ir will work reliably for years. Reliable data communications at speeds of up to 115k baud can be transmitted by the both versions of the cradle. The Mobile IntelliBase and Mobile Base infrared connection to the terminal uses IrDA-compliant hardware and software for a standard reliable connection.
Convenient Storage The Mobile IntelliBase and Mobile Base are safe, convenient storage receptacles for the Dolphin terminal.
14 - 1
Page 112
Mobile IntelliBase and Mobile Base Parts and Functions Front Panel The front panel of the Mobile IntelliBase and the Mobile Base has one slot: Spring-Arm Assembly
Terminal Well
DOCK LED COMM LED
14 - 2
Page 113
Spring-Arm Assembly
DOCK LED
Terminal Well
COMM LED
Front Panel of Dolphin Mobile Base Dolphin Terminal Well Place the Dolphin in the well to communicate with a host device and/or to charge the Dolphin’s battery. LEDs There are two LEDs on the front panels of the Mobile IntelliBase and Mobile Base charging/communication cradles. 1. Dock LED Turns solid green when the Dolphin terminal is properly seated into the Dolphin Mobile IntelliBase. 2. COMM LED
Indicates the status of data transfer between the Host Device and the Dolphin terminal as described below:
Comm LED
Description
Red LED
Data is being sent from the Host Device to the Dolphin Mobile IntelliBase/ Mobile Base.
Green LED
Data is being sent from the Dolphin Mobile IntelliBase/Mobile Base to the Host Device.
Orange LED
Data is being sent at high data rates.
14 - 3
Page 114
Rear Panel
Mounting Bracket
Power Supply Connector
RS-232 Communications Port
Rear Panel of Dolphin Mobile IntelliBase
14 - 4
Page 115
Locking Lever
RS-232 Communications Port
Power Supply Connector
Rear Panel of Dolphin Mobile Base The power supply connector and RS-232 connector are located on the back panel of the unit: Power supply connector Use this connector to attach a power supply to the charging/communications cradle. The power supply provides power for communications and battery charging. RS-232 communications port Use a standard serial cable to connect this port to a host RS-232 device.
14 - 5
Page 116
Bottom Panel of Mobile IntelliBase/Mobile Base A four-position Baud Rate switch, located on the bottom of the Mobile IntelliBase, is used to select the communication baud rate. Switch positions and the corresponding baud rates are shown in the chart below. Baud Rate Table For Connecting To PCs Baud Rate
Switch 1
Switch 2
Switch 3
Switch 4
115200
OFF
ON
ON
ON
57600
ON
OFF
OFF
ON
38400
ON
OFF
ON
ON
19200
ON
ON
OFF
ON
9600
ON
ON
ON
ON
Baud Rate Table For Connecting To Modems Baud Rate
Switch 1
Switch 2
Switch 3
Switch 4
115200
OFF
ON
ON
OFF
57600
ON
OFF
OFF
OFF
38400
ON
OFF
ON
OFF
19200
ON
ON
OFF
OFF
9600
ON
ON
ON
OFF
Powering the Dolphin Terminal When seated in the Mobile IntelliBase/Mobile Base, the Dolphin terminal receives the power it needs to charge the battery and to run its internal circuitry. The Dolphin terminal can be stored indefinitely in the charging/communication without damage to the terminal or the Mobile IntelliBase/Mobile Base. Keep the mobile charging/communications cradle plugged in so that the Dolphin terminal battery pack stays fully charged.
Charging A Dolphin Terminal The Mobile IntelliBase/Mobile Base supplies charging power to the Dolphin terminal so that the terminal can monitor the charging of its battery pack. This charging method protects the battery from being damaged by overcharging. Therefore, the Dolphin terminal may be stored indefinitely in the Mobile IntelliBase/Mobile Base without damage to the terminal, the battery pack, or the Mobile IntelliBase/Mobile Base. To charge a Dolphin terminal, follow these steps: 1. Insert a battery pack into the Dolphin terminal. 2. Place the terminal, imager engine window up and the LCD visible, in the terminal well of the Mobile IntelliBase/Mobile Base. 3. Let it glide down into the well until it stops. 4. Once the Dolphin terminal is properly seated, the Dock LED on the Mobile IntelliBase/Mobile Base will be solid GREEN.
Deep-Cycling Batteries For maximum battery life, HHP recommends that you deep-cycle (service) the battery twice before initial use and once a month thereafter. Since the Dolphin 7400 Mobile Intellibase and Mobile Base do not have deep-cycling capabilities, it is recommended that you use the Battery Conditioning Utility software, the IntelliBase+ or a Dolphin QuadBattery Charger. See the Battery Management section in Chapter 3 for more information.
14 - 6
Page 117
Setting Up For Communications with the Mobile IntelliBase/Mobile Base The Mobile IntelliBase RS-232 interface allows the Dolphin terminal to communicate to a personal computer, modem, or any standard RS-232 device using a standard serial cable and communications software. The IrDA 1.0 software stack is integrated into the Mobile IntelliBase/Mobile Base to allow communication between the cradle and devices such as modems or printers that are not IrDA ready or do not communicate with a half duplex serial protocol. This allows any full or half duplex RS-232 device to communicate through the IntelliBase with no IrDA protocol software. See Tables 2 or 3 for the baud rate switch settings.
Installing The Dolphin Mobile IntelliBase Mounting the Mobile IntelliBase Spring Arm Assembly The adjustable mounting bracket holds the terminal securely in place and gives the user a variety of options for mounting the Mobile IntelliBase. See the directions below for mounting the bracket.
Ball joint
Turnscrew
To attach the bracket: 1. Loosen the turnscrew located on the side of the bracket. 2. Attach the bracket to the ball joint on the back of the Mobile IntelliBase and tighten the turnscrew.
14 - 7
Page 118
Installing The Dolphin Mobile Base The Mobile Base has two mounting options - a clamp style for in-premise applications and a standard RAM mount for other mobile applications that allow the Mobile Base to be mounted according to specific needs. The spring-arm assembly holds the terminal securely in place.
Ball joint
Turnscrew
To Attach the Bracket 1. Loosen the turnscrew located on the side of the bracket. 2. Attach the bracket to the ball joint on the back of the Mobile IntelliBase and tighten the turnscrew.
14 - 8
Page 119
Connecting the Cables Connect the Mobile IntelliBase/Mobile Base to the host computer or other device by plugging an RS-232 serial cable into the RS232 Communications Port on the rear of the cradle. Plug the other end of the RS-232 serial cable into the correct port on the host RS-232 device. The wiring of your cable depends on whether the other device is set up as a DCE (Data Communications Equipment) or DTE (Data Terminal Equipment) device. The Mobile IntelliBase/Mobile Base Communication Port is configured as a DCE device. To communicate with a DTE device such as a computer, use a standard (or straight-through) RS-232 cable. To communicate with a DCE device, use either a null modem adapter in line with a standard RS-232 cable, or a null-modem serial cable. You can make your own cables by following the pin configuration in the chart below. To do so, you must determine if your host RS-232 device is 9-pin or 25-pin, and whether it is configured as a DCE or DTE device. HomeBase /Host Port (DCE)
IBM AT DB9 (DTE)
IBM XT DB25 (DTE)
Modem DB25 (DCE)
2
3
2
Pin / Input Signal 2 / (RD) 3 / (TD)
3
2
3
5 / (SG)
5
7
7
4 / (DTR)
4
20
6
6 / (DSR)
6
6
20
7 / (RTS)
7
4
5
8 / (CTS)
8
5
4
Supplying Power to the Dolphin Mobile IntelliBase and Mobile Base The Mobile IntelliBase and Mobile Base can both be powered from either a 12 -48 volt DC source. Power is connected to the input power connector located on the rear of the Mobile IntellieBase. HHP recommends that you leave the Mobile IntelliBase connected to its power source at all times, so that it is always ready to use.
Setting the Baud Rate After connecting the cables and supplying power to the Mobile IntelliBase, set the baud rate switch. Refer to the Baud Rate Tables earlier in this section for guidance on setting the switch.
14 - 9
Page 120
Configuring the Dolphin Terminal The Communications Properties must be configured on Dolphin 7400/7450 terminal in order for it to communicate with the Mobile IntelliBase/Mobile Base. To set Communications Properties: 1. Select Start>Settings>Control Panel>Communication Settings. 2. Select the PC Connection tab.
Communications Properties 3. Select the desired option for connecting to the desktop computer. Choose IrDA for Mobile IntelliBase IrDA connection and click OK. 4. Place the Dolphin in the Mobile IntelliBase. 5. On the Dolphin 7400 desktop, double-tap on ActiveSync.
14 - 10