Page 71
Enter configuration Exit and Save configuration
| Gun Display Parameters ||
( DISPLAY FONT SIZE )
small font (6 x 8)
16 x 4 characters on display medium font (8 x 8)
large font (12 x 16) 12 x 4 characters on display
8 x 2 characters on display
(__DISPLAYTIMEOUT timeout Read 2 numbers in the range 00-99:
| | 00 = disables Display Timeout (always on). 01 to 99 = timeout from 1 to 99 seconds.
DISPLAY BACKLIGHT } backlight off
| backlight on
3.40 - System Configuration
Page 72
Enter configuration Exit and Save configuration
| Gun Display Parameters ||
DISPLAY CONTRAST } lighter
| | | | IM | darker
Read the code until the desired contrast is reached.
DISPLAY MODE } Normal | | | | | | | Clear display after decode Local echo | | | | ll
For further details, see par. 4.7.1.
System Configuration - 3.41
Page 73
CODE SELECTION PARAMETERS EAN/UPC FAMILY
DEFAULT EAN 8/EAN13 UPC A/UPC E check digit transmitted no conversions
2/5 FAMILY
Interleaved 2/5 check digit control and transmission variable length code: 4-55 characters
CODE 39 FAMILY
Standard Code 39 no check digit control variable length code: 1-32 characters
CODE 128 FAMILY
Code 128
CODE 93 not enabled
CODABAR FAMILY not enabled
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure for this code group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
3.42 - System Configuration
Page 74
Enter configuration Exit and Save configuration
| ll HI Code Selection A ll
DISABLES ALL CODE FAMILIES
NOTE
The reader allows up to 5 code selections. This does not limit the number of CODES enabled to 5, as it depends on the code family:
ONE code from EAN and 2/5 families
SINGLE SELECTION
MORE codes from Code 128, Code 39 and Codabar families
Example 5 code selections: 1. 2/5 Interleaved 2. 2/5 Industrial 3. Code 128 + EAN 128 4. Code 39 Full ASCII + Code 32 5. UPC AJUPCE
In this section all SINGLE code selections are underlined and in bold.
System Configuration - 3.43
Page 75
Enter configuration Exit and Save configuration
| ll HI Code Selection A ll
(. EAN/UPC FAMILY disables the family
Read a single code or combination code selection
EAN 8
Cc
EAN 8/EAN 13/UPC A/UPC E with and without ADD ON
WITH ADD ON EAN 8/EAN 13/UPC A/UPC E
WITHOUT ADD ON | II | ]
EAN 8/EAN 13/UPC A/UPC E EAN 8/EAN 13
EAN 8/EAN 13 | | | I
| I | UPC A/JUPC E 3.44 - System Configuration
UPC A/JUPC E |
Page 76
Enter configuration Exit and Save configuration
| ll HI Code Selection A ll
EAN/UPC CHECK DIGIT TX SELECTIONS
For each code type in this family you can choose to transmit the check digit or not
EAN 8 EAN 13
| | | check digit transmission UPCA
| | no check digit transmission
UPC E
CONVERSION OPTIONS
UPC E to UPC A conversion
UPC A to EAN 13 conversion
| UPC E to EAN 13 conversion
| EAN 8 to EAN 13 conversion
System Configuration - 3.45
Page 77
Enter configuration
| Code Selection
Exit and Save configuration
( 2/5 FAMILY )
disables the family
Read the desired family code Interleaved 2/5
Normal 2/5 (5 Bars)
Industrial 2/5 (IATA)
Matrix 2/5 (3 Bars)
0)
The pharmaceutical code below is part of the 2/5 family but has no check digit nor code length selections. Code CIP/HR
French pharmaceutical code
3.46 - System Configuration
@
Read a check digit selection no check digit control check digit control and transmission check digit control without transmission
@ Read 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length.
The maximum code length is 55 characters.
The minimum code length must always be less than or equal to the maximum.
Examples:
0155 = variable from 1 to 55 digits in the code.
1010 = 10 digit code length only.
Page 78
Page 79
Enter configuration Exit and Save configuration
| ll HI Code Selection A ll
(CODE 128 FAMILY J disables the family
Code 128 control without transmission of check digit |
| EAN 128 control without transmission of check digit
( CODE 93 )
disables the code
| Code 93 control without transmission of check digit
3.48 - System Configuration
Page 80
Enter configuration Exit and Save configuration
| ll HI Code Selection A ll
( CODABAR FAMILY } disables the family
For Standard Codabar:
@® Read the desired equality control code @ _ Read a start/stop transmission selection
Standard Codabar no start/stop character equality control |
| no transmission
| transmission
The Codabar ABC code below uses a fixed start/stop character transmission selection. Codabar ABC no start/stop character equality control but transmission.
Standard Codabar start/stop character equality control |
CODE LENGTH (optional) The code length selection is valid for the entire Codabar family.
Read 4 numbers for the code length where: | First 2 digits = minimum code length.
set code length
Second 2 digits = maximum code length.
The maximum code length is 44 characters. The minimum code length must always be less than or equal to the maximum.
Examples: 0144 = variable from 1 to 44 digits in the code. 1010 = 10 digit code length only.
System Configuration - 3.49