Page 61
GUN OPERATING PARAMETERS
PARAMETERS
DEFAULT
CODE IDENTIFIER disabled
RADIO TIMEOUT
1/2 sec.
SET DATE AND TIME TIME STAMPING FORMAT disabled
TIME STAMPING DELIMITER disabled
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
3.30 - System Configuration
Page 62
Enter configuration Exit and Save configuration ll Gun Operating Parameters lH
( CODEIDENTIFIER disabled
DATALOGIC standard | | | ! | |
For more details, see par. 4.4.1.
RADIO TIMEOUT )
Read 3 numbers in the range 000-255: 000 = disables Radio Timeout (always on). 001 to 255 = timeout from .063 to 16 seconds.
For more details about default values, see par. 4.4.2.
( SET DATE AND TIME )
set time
Read 4 numbers for HHMM set date
Read 6 numbers for DDMMYY
System Configuration - 3.31
Page 63
Enter configuration Exit and Save configuration ll Gun Operating Parameters lH
( TIME STAMPING FORMAT } disabled hour/minutes/seconds month/day/year hour/minutes/seconds day/month/year hour/minutes/seconds month/day/year day/month/year
For more details, see par. 4.4.1.
(TIME STAMPING DELIMITER } disabled select delimiter
Read 2 HEX characters in the range 00-FE
For more details, see par. 4.4.1.
3.32 - System Configuration
Page 64
READING PARAMETERS PARAMETERS
DEFAULT
TRIGGER SIGNAL level
TRIGGER TIMEOUT
10 sec.
READS PER CYCLE
1
SAFETY TIME
.5 sec.
SINGLE-STORE disabled
POWER-OFF TIMEOUT
8 hours
GOOD TRANSMISSION BEEP enabled
BEEPER INTENSITY BEEPER TONE high 2
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
System Configuration - 3.33
Page 65
Enter configuration Exit and Save configuration
| Reading Parameters || f TRIGGER SIGNAL )
trigger active level trigger active pulse
See par. 4.5.1 for details.
(__TRIGGERTIMEOUT } auto-off timeout | | | | Read 2 numbers in the range 00-99:
00 = disables the trigger timeout 01-99 = corresponds to a max. 99 sec. delay after the trigger press before turning the laser off automatically.
See par. 4.5.2 for details.
f READS PER CYCLE )
one read per cycle
| multiple reads per cycle
See par. 4.5.3 for details.
( SAFETY TIME ) safety time . Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms.
01 to 99= timeout from .1 to 9.9 seconds before a
Limits same code consecutive read on same code.
consecutive reading. See par. 4.5.4 for details.
3.34 - System configuration
Page 66
Page 67
Enter configuration
Reading Parameters ||
Exit and Save configuration
(_BEEPER INTENSITY beeper off
|| | | ll low intensity | | ll high intensity
( BEEPER TONE )
tone 1
| | | | ll | tone 2
3.36 - System configuration
Page 68
DECODING PARAMETERS PARAMETERS
DEFAULT
INK SPREAD enabled
OVERFLOW CONTROL enabled
INTERDIGIT CONTROL enabled
CAUTION Before changing these parameter values read the descriptions in par. 4.6.
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
System Configuration - 3.37
Page 69
Enter configuration Exit and Save configuration
| Decoding Parameters ||
( INK-SPREAD )
disabled enabled
See par. 4.6.1 for details.
( OVERFLOW CONTROL )
disabled enabled
See par. 4.6.2 for details.
(_INTERDIGITCONTROL disabled enabled
See par. 4.6.3 for details.
3.38 - System Configuration
Page 70
GUN DISPLAY PARAMETERS
PARAMETERS
DEFAULT
DISPLAY FONT SIZE small
DISPLAY TIMEOUT
8 sec.
DISPLAY BACKLIGHT off
DISPLAY CONTRAST normal
DISPLAY MODE normal
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
System Configuration - 3.39