The text of a manual · part 6 of 12
DLL6000-R/OM6010-R System Manual, pages 51 to 60
Pages 51 to 60 of 117
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic OM6010
Page 51
Page 52
Enter configuration Exit and Save configuration
HL PEN EMULATION VU
( OVERFLOW )
narrow medium wide
See par. 4.3.2 for details.
( OUTPUT LEVEL )
normal (white = logic level 0)
inverted (white = logic level 1)
See par. 4.3.3 for details.
( IDLE LEVEL )
normal (black level)
inverted (white level)
System Configuration - 3.21
See par. 4.3.3 for details.
Page 53
CRADLE OPERATING PARAMETERS PARAMETERS HEADER TERMINATOR
DEFAULT no header RS232: CR-LF WEDGE: CR
ADDRESS STAMPING disabled
ADDRESS DELIMITER disabled
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group = Follow the procedure given for this code group
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
3.22 - System Configuration
Page 54
Enter configuration Exit and Save configuration
| | ll ll Cradle Operating Parameters ll | ll ll ( HEADER )
no header
| | | | | | | one character header two character header | | | | | MM | | lll | ll three character header four character header | | | | ll ll IMM
( TERMINATOR )
no terminator
| | | | | ll | one character terminator two character terminator | | | | ll ll
| | | Il l ll three character terminator four character terminator | | | ll I |
After selecting the desired Header/Terminator code, read the character(s) from the HEX table. four character header cow |i
For more details about default values, see par. 4.4.1. For Terminals see also table in par. 4.4.1, Extended Keyboard To Hex Conversion Table.
+ 41 + 42 + 43 + 44 = Header ABCD
System Configuration - 3.23
Page 55
Enter configuration Exit and Save configuration
| Cradle Operating Parameters ll
ADDRESS STAMPING }
Gun Address Stamping disabled
Gun Address Stamping enabled
| Cradle Address Stamping disabled
Cradle Address Stamping enabled
Gun Address Delimiter disabled
Gun Address Delimiter enabled
Read 2 HEX characters in the range 00-FE
| Cradle Address Delimiter disabled
Cradle Address Delimiter enabled
Read 2 HEX characters in the range 00-FE
For more details, see par. 4.4.1.
3.24 - System Configuration
Page 56
BATTERY CHARGING
PARAMETER OM6010-R BATTERY TYPE
DEFAULT Auto-detect
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of the page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group
3.
Read the Exit and Save Configuration code ONCE, available at the top of the page.
System Configuration - 3.25
Page 57
Enter configuration Exit and Save configuration
| Battery Charging |
OM6010-R BATTERY TYPE } auto-detect
Alkaline
NiMh/NiCd
Li-lon
It is strongly recommended to configure the cradle with the dedicated battery type code. This will also slightly reduce charging time.
Select the Auto-detect code to charge different type battery guns with the same cradle.
3.26 - System Configuration
Page 58
NETWORK PARAMETERS FOR MULTIDROP NETWORK SYSTEMS ONLY
PARAMETER ECHELON FIELDBUS
DEFAULT disabled
TO CHANGE THE DEFAULT VALUES
1.
Read the Enter Configuration code ONCE, available at the top of the page.
2.
Read configuration codes from the desired groups = Choose only one code from each selected group
3.
Read the Exit and Save Configuration code ONCE, available at the top of the page.
System Configuration - 3.27
Page 59
Enter configuration Exit and Save configuration
| Network Parameters ||
ECHELON FIELDBUS } disabled
Master
Slave
To configure the network communications correctly, the cradle connected to the Host must be configured as the Master and all other cradles connected to the multidrop line must be configured as Slaves.
After reading the Exit and Save Configuration code, you must power the cradle(s) off and then on again for the configuration to be recognized.
3.28 - System Configuration
Page 60
G UN
PARAMETERS
System Configuration - 3.29