The text of a manual · part 3 of 12

DLL6000-R/OM6010-R System Manual, pages 21 to 30

Pages 21 to 30 of 117

The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic OM6010

Page 21 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

RS232 CONNECTION

Power Supply

2.8 - Mounting And System Connections

Page 22 read from a scan by OCR; it may hold reading errors

DATALOGIC DLL6000-R/OM6010-R SYSTEM

WEDGE CONNECTION

Letters

Power Supply

Keyboard cable

Mounting And System Connections - 2.9

Page 23 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

PEN EMULATION CONNECTION te Power Supply a

2.10 - Mounting And System Connections

Page 24

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2.2.2 Multidrop Layouts Even though many stand alone systems can operate in the same physical area without interfering with each other, it may be desirable to bridge data from multiple cradles in a network to a single Host. Each OM6010-R cradle is designed to connect with other cradles in order to build a Multidrop cradle network. The Multidrop system requires the installation of the LA6010 Multidrop module in each cradle. Join Join

Bind Multidrop Network using Echelon cables

Slave

Host Bind

Bind Master

RS232 / Wedge / Pen

Slave

Bind Bind

Slave Slave

Figure 2.10 - Multidrop system

The multidrop system allows several cradles to be chained together in a Master/Slave Multidrop network configuration. The Master is connected to the Mounting And System Connections - 2.11

Page 25

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

Host through the multistandard interface by connecting an RS232, Wedge or Pen emulation cable into the Host connector (as in the stand alone system). The Master cradle bridges data from the Slave cradles to the Host. In this way the Master cradle provides communications between a single Host and all guns in the system (those Joined or Bound to the Master and to the Slaves). See par. 6.3 for system configuration specifications.

Roaming Furthermore, to increase the flexibility of the system, guns can be easily joined to different cradles in the system without having to go through the Join procedure. This facilitates "roaming", in which any given gun may be used in areas covered by other cradles. To do this, scan a Code 128 Subset B barcode with the following contents: $+HQxxx$- , where xxx is the 3-digit address of the cradle (previously set through the bind procedure) which the gun must be joined to.

Mounting LA6010 Multidrop Module When building a Multidrop network among several OM6010-Rs, you must install one LA6010 interface module inside each cradle.

1. Remove the OM6010-R from its mounting base: unscrew the cradle fixing screw and detach the cradle from the base by holding the base tight and pushing the cradle backwards. Figure 2.11 - OM6010-R top view

2.12 - Mounting And System Connections

Page 26

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2. Turn the OM6010-R upside-down and open it by unscrewing the four fixing screws:

Fixing screws

Figure 2.12 – OM6010-R – bottom surface

3. Insert the LA6010 into the connector provided on the PCB, orienting it exactly as shown in the figure on the right:

Figure 2.13 – OM6010-R – inside

4. Close the OM6010-R and tighten the fixing screws. 5. Reattach the cradle body to the mounting base by sliding it along the mounting tabs until aligned.

6. Fix the cradle to the base by means of the fixing screw (see Figure 2.11). In case you are installing the LA6010 in a cradle which has already been configured, you must re-send the address to the cradle. To do this you can choose either of the following methods: a) Send the string $+HFxxx$- to the cradle over the serial interface, where xxx = previous cradle address. b) Use the gun bound to the cradle to repeat the bind procedure as described in step 7 of the configuration procedure on page 3.3.

Mounting And System Connections - 2.13

Page 27

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

Network Connections The multidrop network is a bus system which is propagated from one cradle to another using stand alone cables. This is possible thanks to the two echelon connectors on the rear panel of the cradle. The two echelon connectors Power Supply are identical in every respect Connector so that the point-to-point cables can be chained together without limitations concerning the bus wiring. Obviously cable Host length is to be kept to a Connector minimum as with all bus Echelon Connectors systems.

Figure 2.14 - OM6010R rear panel

To The Power Supply

Terminators

To the Host Figure 2.15 – Multidrop network connections with terminators

The Multidrop line is made using any category 5 UTP cable and RJ45 connectors. The maximum network cable length is 1300 meters from terminator to terminator. Pin 1 2 3 4 5 6 7 8

Function Power Supply + Power Supply + Power Supply – Power Supply – Terminator Terminator Data (non-polarized) Data (non-polarized)

Pin 1

Data only

Figure 2.16 – Multidrop Cables

When wiring the multidrop cables, note the following: 2.14 - Mounting And System Connections

Power Supply and data

Page 28

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

Pins 5 and 6 should not be connected (for network termination only) and pins 1 to 4 should be connected only if the power has to be propagated from one cradle to the other via the cable. Pins 1 to 4 can provide power for all cradles connected through the Multidrop line. The total number of devices which can be connected to a single power supply depends on the power supply voltage, the wire length and resistance and therefore the voltage drop. Typically, higher power supply voltages allow longer cable connections. Since the cradle draws the same power, (8W) regardless of the supply voltage, with higher voltages the current flowing in the supply cable and the voltage drop are much less. You must take into account the maximum allowable current on the connectors (4 amps). At the maximum cradle input voltage (28V), the maximum power becomes 4A * 28V = 112W, and at 12V, 48W. Therefore you can propagate the power to 14 cascaded OM6010-Rs at 28V and to 6 OM6010-Rs at 12V (provided the cable voltage drop is very low). If you have more cradles than this you can power them in groups and connect the groups via cables with unconnected power.

Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly terminated. The cradle has an internal terminator that can be connected to the bus by shorting pins 5 and 6 of any one of the two network connectors. The easiest way of terminating the network is to insert a connector with pins 5 and 6 connected by Figure 2.17 – Terminator a short wire. for Multidrop Network

2.3 DLL6000-R BATTERY MAINTENANCE 2.3.1 Battery Type According to the DLL6000-R model, you can install the following battery types: 2 NiMh, NiCd or Alkaline AA batteries 1 Li-ION battery Mounting And System Connections - 2.15

Page 29

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

2.3.2 Battery Charging Once the system is connected and powered, you can place the DLL6000-R into the cradle to charge the battery. When the scanner is correctly inserted in the cradle, the red LED on the cradle goes on to indicate that the battery is charging. The green LED on the cradle goes on when the battery is completely charged. When using NiCd or NiMh batteries, frequent recharging before fully discharging can cause a “memory effect” in which the batteries assume a reduced capacity. Since it is not practical to wait for the gun to be fully discharged before recharging it, the OM6010-R and the C6010 are provided with a batteryreconditioning feature which overcomes the “memory effect” problem. To perform battery reconditioning, simply press the battery-reconditioning key on the cradle control panel: the battery will be fully discharged in a short period of time (red LED flashing), then automatically recharged. We recommend performing the battery reconditioning once every few months or whenever you feel the battery capacity has decreased.

NOTE

Reconditioning cycles only have effect for NiCd and NiMh batteries. Li-Ion batteries do not have a “memory effect” problem and the reconditioning cycle has no effect on them.

2.3.3 Replacing DLL6000-R Batteries To change the batteries in your DLL6000-R scanner, proceed as follows:

1. Unscrew the battery cover screw.

2.16 - Mounting And System Connections

Page 30

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2. Open the battery cover. NOTE When the batteries are extracted from the scanner, the timer maintains the current hour and date for about 1 minute.

3. Replace the old batteries with new ones, then screw the battery cover back into place.

NiMh, NiCd, or Alkaline AA batteries

Li-Ion battery

CAUTION Dispose of used batteries properly. When employing Lithium batteries, do not disassemble, modify, heat or throw them into fire. This could cause leakage of liquid, generation of heat or, in extreme cases, explosion. Replace only with the same type recommended.

Mounting And System Connections - 2.17