Page 11

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

OK

Not Advised Figure 1.2 - Code reading position

Adapt the reading distance to the code features and operating needs.

NOTE

During configuration keep the scanner close enough to the codes to assure the selection of the correct code.

1.1.2 Reading Diagram 10

20

30

40

50

60

70

80 cm

30

20

0.19 0.25 0.38 mm

0.12 mm

10 0

10 20

30 cm

1.2 - Introduction

0.12 mm

0.19 mm

0.25 mm

0.38 mm 0.50 mm 1.00 mm

1.38 mm

Page 12

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

1.1.3 DLL6000-R Indicators DLL6000-R series readers have two LEDs and a beeper. They signal several operating conditions which are described in the tables below. POWER UP Beeper LLLL H H H H Long tones HLHL

Meaning Parameters loaded correctly Parameter loading error, reading or writing error in the non-volatile memory Hardware error in EEPROM

CONFIGURATION Beeper

Meaning

HHHH

Correct entry or exit from configuration mode

L° L L L°

Good read of a command Command read error

DATA ENTRY Red LED

Green LED

Beeper

ON

Meaning Laser active

Flashing

HHHH .

Low battery

Pulse

L°

Good read

Pulse

L°*

Good transmission

H L Long tones

TX failure

BIND AND JOIN COMMANDS Green LED

Beeper

ON L° H L Long tones

Meaning Command accepted; Gun ready to be inserted in the cradle Success Failure

° tone and intensity are user-configurable * the good transmission beeper can be disabled.

H = high tone L = low tone

Introduction - 1.3

Page 13

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

1.2 OM6010-R CRADLE / C6010 CRADLE The OM6010-R is a cradle with radio which allows wireless communication between one or more DLL6000-R series scanners and a Host computer. The OM6010-R also provides battery recharging for the scanners. The C6010 is the charger-only version of the cradle. When several scanners use the same OM6010-R, the battery recharging operation can be speeded up by employing one C6010 for each scanner which does not have a dedicated OM6010-R.

1.2.1 LA6010 Accessory The LA6010 LAN interface module can be mounted to the OM6010-R to connect several cradles in a multidrop network. Refer to Chapter 2 for LA6010 mounting.

1.2.2 OM6010-R / C6010 Indicators Both the OM6010-R and the C6010 are equipped with three LEDs which signal the operating conditions described in the tables below. CHARGE STATUS Red LED

Green LED Meaning

ON

OFF

OFF

ON

Charging End of charge

OFF

OFF

No battery inserted

Flashing

OFF

Discharging (see "Battery Maintenance" section)

Flashing

Flashing

Shorted or open battery

POWER / COMMUNICATION Yellow LED

Meaning

ON

Power applied, no communication

OFF

Error in reading EEPROM parameters

OFF pulse * N.A. on C6010

1.4 - Introduction

Transmission over the Host port*

Page 14

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2 MOUNTING AND SYSTEM CONNECTIONS The installation of the Cordless Reading System requires mounting each cradle, connecting the interface cable to the Host, and connecting the power supply to the cradle.

2.1 MOUNTING THE OM6010-R / C6010 CRADLE The cradle package contains the following devices: OM6010-R / C6010 Cradle with Base OM6010-R Quick Reference / C6010 Quick Reference OM6010-R Antenna

2 adhesive strips

3 mounting screws

4 rubber feet

3 threaded dowels

1 alignment plate

The cradle (either OM6010-R or C6010) can be mounted for portable or fixed desktop usage, or it can be fixed to a wall:

Desktop Use

Wall-mount Use

Mounting And System Connections - 2.1

Page 15

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

2.1.1 Portable Desktop Use For desktop use, the OM6010-R is already correctly positioned on the base.

Base

1. Carefully clean the rubber feet seat of the base to remove any impurities that could reduce adhesion.

2. Remove the protec- tive plastic from the rubber feet and stick them onto the bottom surface of the base.

Rubber foot seat (4) Figure 2.1 Rubber foot placement

3. Insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.

2.2 - Mounting And System Connections

Page 16

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2.1.2 Fixed Desktop Use For fixed desktop installation, use the adhesive strips.

1. If you are installing several cradles and you desire to align them, you can use the alignment plate (see Alignment Plate Installation), otherwise continue with step 2.

2. Carefully clean

Adhesive strip seats the adhesive strip seat of the base to remove any impurities that could reduce adhesion.

Figure 2.2 – Adhesive strip placement

3. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.

4. Remove the plastic from the other side of the strips and affix the base to the table.

5. Insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.

Mounting And System Connections - 2.3

Page 17

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

2.1.3 Wall Mounting For wall mounting, the base is positioned as shown in Figure 2.4.

1. Unscrew the cradle fixing screw and detach the cradle from the base by holding the base tight and pushing the cradle backwards.

2. If you are installing several cradles and you desire to align them, you can use the alignment plate (see Alignment Plate Installation), otherwise continue with step 3.

Figure 2.3 - OM6010-R / C6010 top view

3. Using the mounting holes on the base as a pattern, mark the wall where you desire to mount the OM6010-R.

4. Drill holes.

three appropriate size

5. Insert the threaded dowels into the holes.

6. Position the base on the wall and affix it by means of the three screws.

7. Reattach the cradle body by sliding it along the mounting tabs until aligned.

8. Fix the cradle to the base by means of the fixing screw (see Figure 2.3).

Figure 2.4 - OM6010-R wall mounting

9. Insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.

2.4 - Mounting And System Connections

Page 18

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

2.1.4 Alignment Plate Installation

1. Snap the Alignment Plate into the holes provided on the base so that the plate remains extended from the side of the base.

Figure 2.5 – Alignment Plate

2. Snap the next base onto the remaining pins of the Alignment Plate.

Alignment Plate Holes

Figure 2.6 – Alignment Plate Holes

Mounting And System Connections - 2.5

Page 19

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

2.2 BASIC SYSTEM LAYOUTS There are two basic system layouts that can be employed: stand alone systems and multidrop systems.

2.2.1 Stand Alone Layouts Single gun

Multiple guns Join Join

Host 1

Host 1 Bind

Bind

Figure 2.7 - Stand Alone Connections

In stand alone systems, each cradle is connected to a single Host. Many stand alone connections can operate in the same physical area without interference, provided all guns in the system have different addresses. Since the cradles can communicate to multiple DLL6000-R scanners, you might find it useful to employ one or more C6010 battery chargers in addition to the OM6010-R cradle, so that the battery re-charging operation can be performed for several scanners at the same time. 2.6 - Mounting And System Connections

Host 1 Bind

Host 2 Bind

Host 3 Bind

Figure 2.8 – Multiple Stand Alone Systems in the Same Area

Page 20

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

CAUTION Connections should always be made with power OFF!

Connecting / Disconnecting The OM6010-R Interface Cable The OM6010-R incorporates a multistandard interface which can be connected to a Host by simply plugging an RS232, Wedge or Pen emulation cable into the Host connector, visible on the rear panel of the cradle. To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle. Push down on the clip while unplugging the cable.

OM6010-R interface cable to Host Figure 2.9 – Disconnecting the cable.

Mounting And System Connections - 2.7