Page 31
DLL6000-R/OM6010-R SYSTEM DATALOGIC
2.18 - Mounting And System Connections
Page 32
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
3 SYSTEM CONFIGURATION To start the system up, perform the operations represented in the flow-chart below, following the given sequence. Restore Gun Default
Set Date and Time
Set the Gun Address
Bind the gun to the OM6010-R
Restore the OM6010-R Default
Select the OM6010-R Interface
The system is ready to operate according to the gun and OM6010-R default configurations
System Configuration - 3.1
Page 33
DLL6000-R/OM6010-R SYSTEM DATALOGIC
3.1 SYSTEM START-UP When the OM6010-R is connected and powered, configure the DLL6000-R by reading the following codes in the given sequence and follow the instructions.
Note: Open the folded page at the end of this Manual for the Numeric code selections.
Restore DLL6000-R default
" UL
Default parameter settings are listed in par. 3.1.2.
Enter configuration
Set Date
3 ALU + six digits for Day, Month and Year (DDMMYY).
Set Time
* WINNT + four digits for Hours and Minutes (HHMM).
Set Gun Address
° MU + three digits for the DLL6000-R Address (from 000 to 126).
All guns used in the same area must have different addresses.
3.2 - System Configuration
Page 34
DATALOGIC DLL6000-R/OM6010-R SYSTEM
Exit and Save configuration 6 AUT
7. Read the Bind code to pair the DLL6000-R to the OM6010-R:
The reader is dedicated to the cradle. Any previously bound reader will be excluded.
To connect several guns to the same cradle see the following paragraph ‘Using Multiple Guns with Same Cradle’.
HU
The green LED on the DLL6000-R will go on: the scanner is ready to be inserted into the cradle.
8, Firmly insert the scanner into the OM6010-R: a beep will be emitted, signaling that the OM6010-R has been paired to the DLL6000-R.
9. Read the Restore Cradle default code
Restore Cradle default
Default parameter settings are listed in par.3.1.3.
System Configuration - 3.3
Page 35
DLL6000-R/OM6010-R SYSTEM DATALOGIC
10. Read the Interface Selection code for your particular application:
RS232 Interface
II PEN EMULATION
Interface IBM AT or PS/2 PCs
WEDGE Interface IBM XT III | | HII MAM AA | UANAUI IBM SURE‘
=, IBM Terminals: 31xx, 32xx, 34xx, 37xx *, oer KEY TRANSMISSION oe- make-only keyboard or make-break keyboard
KEYBOARD TYPE advanced keyboard typewriter keyboard
You can change any interface selection by simply reading another interface selection code.
RS232 and WEDGE interface selection codes automatically restore header and terminator default values (see par. 4.4.1).
* See par. 4.2.1.
3.4 - System Configuration
Page 36
DATALOGIC DLL6000-R/OM6010-R SYSTEM
11.
Wns
123456
Test O.K.: two short beeps Test Failure: no beep or a long high-tone beep followed by a long low-tone beep.
3.1.1 Using Multiple Guns With Same Cradle
If you want to use several guns associated with the same cradle, you must first Bind the cradle with one of the guns (see the previously described configuration procedure).
Successive guns can be associated with this same cradle by following the configuration procedure substituting the Bind command with Join.
In this case the procedure ends with step 8.
|
WARNING
If the cradle is not Bound to a gun, its address assumes a random value which can cause conflicts and malfunctions to other cradles within its range.
System Configuration - 3.5
Page 37
DLL6000-R/OM6010-R SYSTEM
DATALOGIC
3.1.2 Gun Default Configuration Reading Parameters Trigger signal Trigger timeout Reads per cycle Safety time Single-store Power-off timeout Beeper intensity Beeper tone Good transmission beep level 10 sec. one .5 sec disabled 8 hours high 2 enabled
Decoding Parameters Ink spread Overflow control Interdigit control enabled enabled enabled
Gun Operating Parameters Code identifier Time stamping format Time stamping delimiter * Radio timeout disabled disabled none 1/2 sec.
Display parameters Font size Display timeout Backlight Contrast Display DLL mode small 8 sec. off normal normal
Code Selection EAN 8/EAN 13 / UPC A/UPC E Interleaved 2/5 Standard Code 39 Code 128 Code 93; Codabar
Check digit transmission, no conversions. Check digit control and transmission, variable length code: 4-55 characters. No check digit control, variable length code: 1-32 characters. Disabled
* The restore default command does not affect the selection made for this parameter. 3.6 - System Configuration
Page 38
Page 39
DLL6000-R/OM6010-R SYSTEM
DATALOGIC
3.2 CHANGING SYSTEM CONFIGURATION The DLL6000-R and OM6010-R default parameters can be changed by following the procedure below. 1. Open the folded page in Appendix C with the Hex-Numeric table and keep it open during configuration. 2. Go to the section of the group to modify. 3. Follow the procedure for that section. System parameters are grouped according to the following figure:
Cradle Parameters RS232 Parameters
WEDGE Parameters
Cradle Operating Parameters
PEN Emulation Parameters
Battery Parameters
Network Parameters
Gun Parameters Gun Operating Parameters
Reading Parameters
Decoding Parameters
Gun Display Parameters Code Selection
3.8 - System Configuration