Page 101

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

6.2 OM6010-R / C6010 TECHNICAL FEATURES OM6010-R

C6010

Electrical Features Supply voltage Power consumption Indicators Time of recharge

10..28 Vdc max. 8 W (charging) * Charger on (red) Charger on (red) Charge completed (green) Charge completed (green) Power (yellow) Power / Data (yellow) NiMh / NiCd batteries: 2 hours Li-Ion batteries: 5 hours

Host interfaces RS232 WEDGE

PEN Emulation

300..19200 baud IBM AT, XT, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals supported Selectable minimum pulse from 200 µS to 1.2 mS

Environmental Features Working temperature Storage temperature

-10 to +40 °C -10 to +60 °C

Humidity

90 % non condensing

Protection

IP40

Mechanical Features Weight with mounting support about 600 g.

Dimensions (without antenna)

185 x 115 x 104 mm

Material

ABS

* Having a switching regulator inside, the OM6010-R and C6010 draw the same power, regardless of the supply voltage. i.e. as the input voltage increases the current drawn decreases.

6.2 - Technical Features

Page 102

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

6.3 SYSTEM FEATURES European Models

USA Models

Working Frequency

433.92 MHz

910 MHz

Bit rate

19200 baud

Radio Features

Range Max number of guns per cradle

36800 baud 50 m open air 32

Echelon Network Features Max. number of cradles per system

64

Max number of devices per system

127

Echelon bit rate

78 Kbaud

Max system cable length

1300 meters

Technical Features - 6.3

Page 103 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

6.4 - Technical Features

Page 104

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

APPENDIX A

HOST CONFIGURATION STRINGS

In this section we provide a description of how to modify the configuration using serial command strings sent from the Host. This method requires the RS232 interface.

Command

$+

$-

CR Carriage return character (0D Hex.) Exit and Save configuration

Character sequence in following tables Enter configuration environment

For RS232 user’s, the configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following: Example: Multiple command programming sequence: $+

BG1 BH0

AC410132

$-

CR

Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment

Each configuration parameter setting removes the condition previously active for that parameter.

Host Configuration Strings - A.1

Page 105 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

NOTE

The buffer can contain a maximum of 256 characters. If your programming string goes over this value, you must split it into separate groups, according to the following rules:

e all gun commands must reside in one single string;

e consecutive string transmission must occur after a delay of at least 3 seconds to give the cradle time to process each string.

Many of the following tables list gun parameters. If you include gun configuration commands in your configuration string:

1. Send the string to the cradle.

2. Read the following code with the gun to be programmed:

Get Gun Configuration from Cradle

The green LED will light, signaling the gun has recognized the command.

3. Insert the gun into the cradle. The LED will turn off and you will hear a short beep. Now the gun has accepted the configuration.

4. If you do not turn the cradle off, you can repeat steps 2 and 3 with all the guns you want to configure with the same string.

A.2 - Host Configuration Strings

Page 106

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

SERIAL CONFIGURATION STRINGS

CONFIGURATION COMMANDS DESCRIPTION Restore factory default configuration Transmit the Cradle Software release

STRING $* $!

The above commands do not require $- to exit.

Cradle Parameters INTERFACE SELECTION DESCRIPTION RS232 interface PEN emulation interface WEDGE for IBM AT for IBM AT Alt Mode for IBM XT for IBM SURE1 for IBM Terminal 3153 for IBM Terminals 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals 31xx, 32xx, 34xx, 37xx; make only keyboard

DESCRIPTION Baud rate

Parity Data bits Stop bits Handshaking Radio RX lock Inter-character Delay RX Timeout

RS232 PARAMETERS 150 300 600 1200 2400 4800 9600 19200 Disabled Even Odd 7 8 9 1 2 Disabled RTS/CTS XON/XOFF Disabled Enabled

STRING CP0 CP6 CP500 CP507 CP503 CP506 CP504 CP501 CP502

STRING CD0 CD1 CD2 CD3 CD4 CD5 CD6 CD7 CC0 CC1 CC2 CA0 CA1 CA2 CB0 CB1 CE0 CE1 CE2 EC1 EC0 CK00 - CK99 CL00 - CL99

Host Configuration Strings - A.3

Page 107

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

WEDGE PARAMETERS DESCRIPTION Keyboard Type for Typewriter IBM Terminals 31xx, 32xx,34xx, 37xx: Advanced Keyboard Nationality English French German Italian Swedish USA Spanish Belgian Japanese Russian (Latin) Russian (Cyrillic) Hungarian Yugoslavian Rumenian Czechoslovakian Caps Lock Caps Lock ON Caps Lock OFF Num Lock Num Lock unchanged Toggle Num Lock Inter-character Delay Inter-code Delay

DESCRIPTION Conversion to Code 39 Operating mode

Output level Idle level Minimum output pulse

Overflow

A.4 - Host Configuration Strings

PEN PARAMETERS Disabled Enabled Interpret (does not require $+ or $-) Transparent (does not require $+ or $-) Normal Inverted Normal Inverted 200µs 400µs 600µs 800µs 1 ms 1.2 ms Narrow overflow Medium overflow Wide overflow

STRING FK0 FK1 FJ4 FJ2 FJ3 FJ1 FJ5 FJ0 FJ6 FJ7 FJ8 FJ9 FJA FJB FJC FJD FJE FE1 FE0 FL1 FL0 CK00 - CK99 FG00 - FG99

STRING DA0 DA1 $] $[ DD0 DD1 DE0 DE1 DG0 DG1 DG2 DG3 DG4 DG5 DH0 DH1 DH2

Page 108

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

DESCRIPTION Headers

CRADLE OPERATING PARAMETERS No header One character Two characters Three characters Four characters No terminator One character Two characters Three characters Four characters Gun Address stamping enabled Gun Address stamping disabled Cradle Address stamping enabled Cradle Address stamping disabled Gun Address delimiter select Gun Address delimiter disabled Cradle Address delimiter select Cradle Address delimiter disabled

Terminators

Address stamping

Address delimiter x=

STRING EA00 EA01x EA02xx EA03xxx EA04xxxx EA10 EA11x EA12xx EA13xxx EA14xxxx HU1 HU0 HU3 HU2 HV1y HV0 HY1y HY0 a HEX value representing the ASCII character. For RS232 from 00 to 7F Hex For WEDGE from 00 to 9A Hex y= a HEX value in the range from 00 to FE representing the ASCII character.

DESCRIPTION OM6010-R Battery selection

DESCRIPTION Echelon fieldbus

BATTERY CHARGING

STRING HT0 HT1 HT2 HT3

Autodetect Alkaline battery Li-Ion battery NiMh or NiCd battery

MULTIDROP NETWORK PARAMETERS Disabled Slave Master

STRING HW0 HW1 HW2

Host Configuration Strings - A.5

Page 109

DLL6000-R/OM6010-R SYSTEM

DATALOGIC

Gun Parameters DESCRIPTION Code Identifier

GUN OPERATING PARAMETERS

Time Stamping Format

Time Stamping Delimiter Radio Timeout Set Time Set Date x=

Disabled Datalogic standard AIM standard Disabled Hour/minutes/seconds/month/day/year Hour/minutes/seconds/day/month/year Hour/minutes/seconds Month/day/year Day/month/year Disabled Select delimiter Tout (range is 000 to 255)

STRING EB0 EB1 EB2 HL0 HL1 HL2 HL3 HL4 HL5 HM0 HM1x HH000-HH255 HDhhmm HEddmmyy a HEX value in the range from 00 to FE representing the ASCII character.

hhmm, ddmmyy = ASCII numbers.

DESCRIPTION Trigger Signal Trigger Timeout Reads Per Cycle Safety Time Single-Store Power-Off Timeout Beeper Intensity

Beeper Tone

Good Transmission Beep

READING PARAMETERS Level Pulse One read Multiple reads Disabled Enabled Beeper off Low intensity Medium intensity High intensity Tone 1 Tone 2 Tone 3 Tone 4 Disabled Enabled xx = ASCII numbers in the range 00 - 99.

A.6 - Host Configuration Strings

STRING BA0 BA1 BD00 - BD99 BC0 BC1 BE00 - BE99 HO2 HO3 HPxx BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 HO0 HO1

Page 110

DATALOGIC

DESCRIPTION Ink-Spread Overflow Control Interdigit Control

DESCRIPTION Display Font Size Display Timeout Display Backlight Display Contrast Display Mode Keypad Setting

DLL6000-R/OM6010-R SYSTEM

DECODING PARAMETERS

STRING AX0 AX1 AW1 AW0 AV0 AV1

Disabled Enabled Disabled Enabled Disabled Enabled GUN DISPLAY PARAMETERS Small Medium Large Disabled Enabled Lighter Darker Normal Local Echo Clear display after decode Disabled keypad Key Identifier

STRING HA0 HA1 HA2 HB00-HB99 HC0 HC3 HO7 HO6 HJ0 HJ1 HJ2 HK0 HK1xxyyzz xx = left-key Identifier yy = center-key Identifier zz = right-key Identifier xxyyzz are hexadecimal values representing ASCII characters in the range 00-FE. FF = Key Identifier disabled.

Host Configuration Strings - A.7