Page 111

DLL6000-R/OM6010-R SYSTEM

CODE SELECTION DESCRIPTION Disable ALL family codes EAN/UPC Disable EAN/UPC family EAN 8 EAN 13 UPC A UPC E EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON with and without ADD ON EAN 8/EAN 13 without ADD ON with ADD ON UPC A/UPC E without ADD ON with ADD ON EAN 8 check digit transmission disabled enabled EAN 13 check digit transmission disabled enabled UPC A check digit transmission disabled enabled UPC E check digit transmission disabled enabled UPC E to UPC A Conversions UPC E to EAN 13 UPC A to EAN 13 EAN 8 to EAN 13 Code 39 Disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP/39 Code 32 Code length (max 32)

A.8 - Host Configuration Strings

DATALOGIC

STRING AZ0 AA0 AA2 AA9 AAF AAE AA1 AA5 AA8 AA3 AA6 AA4 AA7 AAG0 AAG1 AAH0 AAH1 AAI0 AAI1 AAJ0 AAJ1 AAA AAB AAC AAD AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx

Page 112

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

CODE SELECTION (continued) DESCRIPTION 2/5 Disable Code 2/5 family Interleaved 2/5 no check digit control (max code length 55) check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control (max code length 55) check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control (max code length 55) check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control (max code length 55) check digit control and transmission check digit control without transmission CIP/HR Codabar Disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC CODABAR no start/stop character equality control but transmission Code length (max 44) Code 128 Disable Code 128 family Code 128 EAN 128 Code 93 Disable Code 93 family control without transmission of check digit xxxx = ASCII numbers that define the code length where: = minimum acceptable First 2 digits code length. Second 2 digits = maximum acceptable code length. The minimum code length must always be less than or equal to the maximum.

STRING AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5 AD0 AD111 AD112 AD121 AD122 AD212 AD*xxxx AI0 AI11 AI21 AK0 AK1

Examples 0132 = 1010 = variable length from 1 to 32 digits in the code. 10 digit code length only.

Host Configuration Strings - A.9

Page 113 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

A.10 - Host Configuration Strings

Page 114 read from a scan by OCR; it may hold reading errors

DATALOGIC DLL6000-R/OM6010-R SYSTEM

APPENDIX B C6010 CONFIGURATION

It is possible to configure the C6010 battery type to charge through any DLL6000-R gun.

1. Read one of the following labels: auto-detect | | | i mui | | |

| IMI HWM

The green LED will light, signaling the gun has accepted the command.

2. Insert the gun in the cradle. The LED turns off and a short beep is emitted.

C6010 Configuration - B.1

Page 115 read from a scan by OCR; it may hold reading errors

DLL6000-R/OM6010-R SYSTEM DATALOGIC

B.2 - C6010 Configuration

Page 116

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

APPENDIX C HEX AND NUMERIC TABLES

OPEN THIS PAGE TO READ THE DESIRED HEX AND NUMERIC SELECTIONS

Hex and Numeric Tables - C.1

Page 117

DATALOGIC

DLL6000-R/OM6010-R SYSTEM

HEX TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SPACE ! " # $ % & ' ( )

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29

* + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T

2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54

U V W X Y Z [ \ ] ^ _ ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

*F&J&P&J-F*J&J-J*F*M-F&F*

*F&J&P&J-J*F*J-J&F*M-F&F*

0

*F&J&P*J-J&F*J&F-J*M-F&F*

1

*F&J&P*J&F-J*J&J-F*M-F&F*

2

*F&J&P*J&J-F*F-J&J*M-F&F*

3

*F&J&P*F-J&J*J-F&J*M-F&F*

4

*F&J&P*J-F&J-F*F-F*M-F&F*

5

*F&J&P-F*F-F-F&J*J*M-F&F*

6

*F&J&P-F&J*J-J&F*J*M-F&F*

7

*F&J&P-J&F*J-J&J*F*M-F&F*

8

*F&J&P&F&M*M&M&F*M*M-F&F*

9

*F&J&P&M&F*M&M&M*F*M-F&F*

A

*F&J&P&M&M*F&F*M&M*M-F&F*

B

*F&J&P&F*M&M&M*F&M*M-F&F*

C

*F&J&P&M*F&M&M*M&F*M-F&F*

D

*F&J&P&M*M&F*F&M&M*M-F&F*

E

F

Backspace

*F&J&P&J&M*J&M&J*J&F-J*J*M-F&F*

Cancels an incomplete configuration sequence