The text of a manual · part 10 of 12
DLL6000-R/OM6010-R System Manual, pages 91 to 100
Pages 91 to 100 of 117
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic OM6010
Page 91
DLL6000-R/OM6010-R SYSTEM
DATALOGIC better to disable single-store so that the user perceives a more consistent behaviour of the trigger in that it always corresponds to code reading.
4.5.6 Power-Off Timeout With Ni-MH, NiCd, or AA batteries, when this timeout is set, a gun which is left unused will power-off after the selected time. The gun will power-up again upon a trigger press. This will save battery power. This parameter is not valid for Li-Ion batteries.
4.6 DECODING PARAMETERS CAUTION These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.
4.6.1 Ink-Spread The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink.
4.6.2 Overflow Control The overflow control parameter can be disabled when decoding codes printed on small surfaces, which don’t allow the use of an overflow space. This command does not effect code families 2/5, Code 128 and Code 93. For the EAN/UPC code family, do not use code combinations. Each code must be selected singularly if this control is disabled. For example, to read EAN8 and EAN13 without overflow control select two codes: EAN8 and EAN13; do not select the EAN8/EAN13 combination. 4.10 - References
Page 92
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
4.6.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.
4.7 GUN DISPLAY PARAMETERS 4.7.1 Display Mode The user can control the gun display behavior according to the following selections: Normal mode: When a barcode is read with the gun: The code is sent to the Host. The gun display is not cleared. Therefore if any previous data was displayed on the gun screen it remains. There is no Local Echo to the gun display. Clear Display After Decode mode: When a barcode is read with the gun: The code is sent to the Host. The gun display is cleared. Therefore if any previous data was displayed on the gun screen it is cancelled and the screen remains blank. There is no Local Echo of the code to the gun display. Local Echo mode: When a barcode is read with the gun:
The code is sent to the Host. The gun display is cleared. The code is also sent to the gun display (Local Echo). The cursor is positioned after the last printed character on the gun display.
Host messages sent to the gun are always written to the gun display. References - 4.11
Page 93
DLL6000-R/OM6010-R SYSTEM DATALOGIC
4.8 SOFTWARE RELEASE
The following codes cause the gun and the cradle to transmit the respective software release to the Host: Gun
Software Release
Cradle Software Release
4.12 - References
Page 94
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
5 COMMUNICATION AND MESSAGE FORMATTING The system always provides gun to host data communication using the message formatting described in par. 4.4.1. However, if the RS232 interface is selected for communication between the Host and the OM6010-R cradle, then the following additional communications between Host and Gun can occur:
The Host can send messages to any gun associated with that cradle to control the Gun's display, LEDs and beeper.
The Gun can send up to 3 user-defined characters to the Host using the 3 command keys on the gun.
These communications and their relative message formatting are detailed in the following paragraphs.
5.1 MESSAGES FROM HOST TO GUN The general format is: [Gun_Address][Gun_Add_delimiter]<Message>CR
NOTE:
If you have enabled the Gun Address Stamping or the Gun Address Delimiter, you must specify them in every message.
If you have not enabled the Gun Address Stamping or the Gun Address Delimiter, you must not specify them. In this case all messages will be implicitly addressed to the 'binded' gun of the cradle directly connected to the serial line.
Messages cannot start with '$+' because they would be interpreted as a configuration command.
You can send a message to the gun only while it is on. This happens when it has sent a message to the host and the radio timeout has not yet expired. (See par. 4.4.2, "Radio Timeout"; command is on page 3.31).
Communication and Message Formatting - 5.1
Page 95
DLL6000-R/OM6010-R SYSTEM
DATALOGIC
If you want to control the gun's beeper from the host, you will also probably want to disable the good transmission beep that is emitted when the code is received from the cradle. (See command on page 3.35).
The message field can store plain text and escape sequences.
Escape sequences are interpreted as commands.
Plain text is directly printed on the display. If writing beyond the end of line, the display does not wrap automatically. Extra characters are ignored. Control characters are not interpreted (i.e. LF, FF, etc.).
5.1.1 Cursor Control ESC [ n A ESC [ n B ESC [ n C ESC [ n D ESC [ G ESC [ r ; c H ESC D ESC E ESC M
Up n rows, no scroll Down n rows, no scroll Right n columns Left n columns CR Move to row r, column c (ESC[1;1H is the upper left character position of the display) Down 1 row, with scroll CR and cursor down 1 row with scroll Up 1 row and scroll
NOTE: Since CR is used as the message terminator, you must use ESC [ G or ESC E to print a CR.
The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing with the large font, actually two rows are written to: the current one and the one below it. You will need two ESC E commands to step from one row to the next when using the large font.
The cursor column position is affected by the currently selected font. Therefore, column 6 is 36 pixels from the left border only if you last selected the 6x8 font; otherwise it could be 48 or 72 pixels from the left border.
5.2 - Communication and Message Formatting
Page 96
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
5.1.2 Font Selection ESC [ 0 m ESC [ 7 m ESC # 4 ESC # 5
ESC # 7
Normal mode Reverse mode Large font: subsequent characters are written on the current row and the row below it using the 12x16 font which allows for two rows of eight characters on the display. Normal font: subsequent characters are written using the 6x8 font which allows for four rows of sixteen characters on the display. Medium font: subsequent characters are written using the 8x8 font which allows for four rows of twelve characters on the display.
5.1.3 Clearing Display ESC [ 0 K ESC [ 1 K ESC [ 2 K ESC [ 0 J ESC [ 1 J ESC [ 2 J
From cursor position to end of line inclusive From beginning of line to cursor position (not inclusive) Entire line From cursor position to end of display inclusive From beginning of display to cursor position (not inclusive) Entire display; moves cursor to upper left corner on display
Communication and Message Formatting - 5.3
Page 97
DLL6000-R/OM6010-R SYSTEM
DATALOGIC
5.1.4 LED and Beeper Control ESC [ 0 q ESC [ 1 q ESC [ 2 q ESC [ 3 q ESC [ 4 q ESC [ 5 q ESC [ 6 q ESC [ 7 q ESC [ 8 q ESC [ 9 q
Emit short High tone + short delay Emit short Low tone + short delay Emit long Low tone + short delay Emit good read tone Emit bad tx tone Wait 100 ms Turn on the green LED Turn off the green LED Turn on the red LED Turn off the red LED
The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper. The LED and Beeper will be controlled by the system after the entire command sequence is interpreted. Example: ESC [ 6 q ESC [ 3 q ESC [ 7 q
Turns on the green LED, emits a good read tone, and turns off the green LED.
ESC [ 6 q ESC [ 5 q ESC [ 7 q
Turns on the green LED for 100 ms and then turns off the green LED.
5.1.5 Setting RTC ESC [ 0 p d d m m y y ESC [ 1 p h h m m
Set date to day, month, year Set time to hours, minutes; seconds are automatically set to 00.
5.4 - Communication and Message Formatting
Page 98
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
5.2 MESSAGES FROM GUN COMMAND KEYS The DLL6000-R series guns with display have 3 command keys that can each be associated with a character to send to the host. By pressing the keys on the gun, the associated character with its relative message formatting is sent to the Host. For example, keys can be used to select items from a menu sent to the gun display by the application program. The general format is: [Header] [Gun_Addr] [Gun_Addr_delimiter] ] [Cradle_Addr] [Cradle_Addr_delimiter] [Time stamp] [Ts_delimiter] [Code ID] KeyID [Terminator]
The messages are handled by the system as if they were barcodes, that's why KeyID can have so many fields appended to it. If in your application there is some chance of reading a 1-char barcode identical to KeyID, the way you can distinguish between the two is to enable the Code ID: The KeyID is the only 1-character long EAN 8 code. Refer to par. 4.4.1 for a compete description of the optional message fields in square brackets. The default characters associated with each key (KeyID) are shown in the following table: Default Key Identifiers Key
KeyID
(left) Key
'<'
ENTER
(center) Key
'='
(right) Key
'>'
Communication and Message Formatting - 5.5
Page 99
DLL6000-R/OM6010-R SYSTEM DATALOGIC
The Key Identifier values can be customized by using the configuration procedure below:
Enter Configuration
Key Identifier | | | where: xx = left-key Identifier yy = center-key Identifier zz = right-key Identifier + xxyyzz xxyyzz are hexadecimal values representing ASCII characters in the range 00-FE. FF = Key Identifier disabled.
Exit and Save Configuration
The keypad can be disabled by reading the following code:
Keypad disabled
5.6 - Communication and Message Formatting
Page 100
DATALOGIC
DLL6000-R/OM6010-R SYSTEM
6 TECHNICAL FEATURES 6.1 DLL6000-R TECHNICAL FEATURES Electrical Features Battery Type Time of recharge NiMh Time of recharge Li-Ion Operating autonomy (typ. continuous reading) Display
(Only available with some models)
Indicators
2 AA NiMh* batteries or 1 Lithium-Ion Sanyo UR-110 battery 2 hours 5 hours 60,000 reads - NiMh 75,000 reads - Li-Ion LCD 4 lines x 16 chars Programmable font and backlight Laser On / battery low LED (red) Good Read LED (green) Programmable Beeper
Laser Features Power (typical) in mW
0.8 mW
Light Source
VLD 670 nm
Scan rate
36 µ 3 scans/sec
Reading field width see reading diagram (par. 1.1.2)
Max. resolution PCS minimum
0.12 mm, 5 mils 15% (Datalogic Test Chart)
Scan angle
42°
Laser Safety Class
2 (IEC 825-1 / CDRH)
Environmental Features Working Temperature
-10 °C to + 40 °C
Storage Temperature
-20 °C to + 50 °C
Humidity
90% non condensing
Drop resistance (on concrete) with display without display Protection
1.5 m 1.8 m sealed against rain and dust
Mechanical Features Weight (with batteries)
about 340 g.
Dimensions
203 x 117 x 69 mm
Material
ABS and Polycarbonate molded with rubber
* It is possible to employ also NiCd or non-chargeable Alkaline AA batteries.
Technical Features - 6.1