Page 51
INSTALLATION
2
2.6 TYPICAL INSTALLATIONS 2.6.1
Standard Installation
The DS6300 scanner is mounted on the ST-237 106° mounting bracket (see Figure 9) which guarantees a built-in Skew angle (S in the figure below) of 16° with respect to the frame plane (typically the Skew angle should be between 10° - 20°). This avoids the direct reflection of the laser light emitted by the scanner. Furthermore, the bracket guides allow adjusting the Tilt angle (T in the figure below, which is typically 0°) for the best scanner orientation:
T
S
Conveyor Direction
Figure 49 – Standard Installation
2.6.2
“45° Skew” Installation
The DS6300 scanner is mounted on the ST-210 90° mounting bracket (see Figure 11). By adjusting the mounting bracket guides, reach 45° for the Skew angle (S in the figure below) to avoid the direct reflection of the laser light emitted by the scanner:
45°
S
Figure 50 – 45° Skew Installation
37
Page 52
DS6300
2
ATTENTION
If using the “45° Skew” installation, the scanner reading performance is not guaranteed to match that measured for the standard installation with Skew angle between 10° - 20° (see reading diagrams in par. 4.3.1).
The ST-210 mounting bracket is an accessory of the DS6300 standard model available in the US-60 kit (order no. 890001020). NOTE
2.7 TYPICAL LAYOUTS The DS6300 scanners can be connected in a variety of layouts depending on the number of scanners used and the required complexity of the reading station. These layouts range from Single Stand Alone to Complex Lonworks Networks. Several power supplies are available to power the reading stations. Photoelectric sensors used as code presence sensors and optical encoders to signal conveyor speed are also available accessories. The following typical layouts refer to the system hardware configurations, but they also require the correct setup of the software configuration parameters (see par. 3.2 for details). The accessories and cables indicated in the following figures are Datalogic products. We suggest their use to guarantee the correct system functioning.
2.7.1
Point-to-Point
Using a Point-to-Point layout, the data is transmitted on the Main interface as well as on the Auxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplex communications. Two different layouts are available according to the DS6300 reader model used for the connection.
38
Page 53
INSTALLATION
2
Master/Slave Models When On-Line operating mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. In the following case, the signal is passed to the DS6300 by the C-BOX 100, which also supplies the system. M/S CAB-600X C-BOX 100
Local Host
Presence Sensor* PG6000
*
P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 51 – Point-to-Point for Master/Slave Models
Fieldbus Models In this case no External Trigger is used and the C-BOX 100 only supplies the reader. The DS6300 (Ethernet, DeviceNet or Profibus model) is connected to a fieldbus remote Host. It can be activated by a signal generated by the remote Host or be always active if working in Automatic operating mode. Remote Host
Fieldbus Network Fieldbus CAB-601X
C-BOX 100
PG6000
Figure 52 – Point-to-Point for Fieldbus Models
39
Page 54
DS6300
2
2.7.2
Pass Through
When Pass Through is activated on the Auxiliary interface, the DS6300 reader (all models) can be integrated in a network consisting of different scanners not provided with a Lonworks interface. This connection mode allows two or more devices to be connected to a single external serial interface. The DS6300 transmits the messages received by its auxiliary interface (RS232 only) onto its main interface. In this configuration a series of scanners can be connected together using RS232 on the main interface and all messages will be passed through this chain to the host. The reading phase of each scanner is independent from the others. In Pass Through connections each scanner is provided with its relative External Trigger (multi P.S.). Applications can be implemented to connect a device such as a hand-held reader to the Auxiliary port for manual code reading capability. For the RS232 connections the maximum cable length is 15 m (50 ft). The DS4600A scanners represented in the following figures are configured in Pass Through mode. P.S.*
P.S.*
Gryphon
DS4600A
<
DS4600A
T
EN T
<
<
EN
<
DS6300 CAB-600X
C-BOX 100
C-BOX 100 MAIN
C-BOX 100
AUX.
P.S.*
2 1
1
2
1
Local Host
PWR-120
1
Main Serial Interface
2
Auxiliary Serial Interface
*
P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 53 – Pass Through Connection for DS6300 Master/Slave Models
40
Page 55
INSTALLATION
2
Remote Host P.S.*
P.S.*
Gryphon
DS4600A
<
<
EN T
CAB-601X
C-BOX 100 AUX
DS4600A
<
<
DS6300
EN T
Fieldbus Network
C-BOX 100
C-BOX 100
P.S.*
2
1
2
1
PWR-120
*
1
Main Serial Interface
2
Auxiliary Serial Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 54 – Pass Through Connection for Fieldbus Models
2.7.3
RS232 Master/Slave
The RS232 master/slave connection is used to integrate a DS6300 reader (all models) in a network consisting of different scanners not provided with a Lonworks interface. The Slave scanners use RS232 only on the main and auxiliary interfaces. Each slave scanner transmits the messages received by the auxiliary interface onto the main interface. All messages will be transferred towards the master. The master scanner is connected to the Host PC on the main RS232 serial interface through the C-BOX 100 (20 mA C.L. can be used if the INT-30 accessory is installed). In RS232 Master/Slave connections the External Trigger signal is unique to the system (single P.S.).
NOTE
The DS6300 master/slave scanner model (DS6300-10X-010 only), working as Master in an RS232 network, may be simultaneously connected to a Lonworks network consisting of DS6300 slave scanners. Be careful when assigning the slave address, since the number of the first Lonworks slave must be a progressive number with respect to the address number defined for the last slave scanner of the RS232 network. For example, if the RS232 network consists of Slave 1 and Slave 2, the address to be assigned to the first Lonworks slave scanner will be Slave 3 (not Slave 1).
41
Page 56
DS6300
2 DS6300- Master C-BOX 100 AUX
CAB-600X
1
EN
MAIN
P.S.*
2
<
<
T
DS4600A Slave 1
Local Host
1
C-BOX 100
2 <
DS4600A Slave 2
EN T
<
PWR-120
C-BOX 100
1 1
Main Serial Interface
2
Auxiliary Serial Interface
*
P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 55 – RS232 Master/Slave for DS6300 Master/Slave Models Remote Host
Fieldbus Network
DS6300 Master
CAB-601X AUX
DS4600A Slave 2
C-BOX 100
2
<
EN T
P.S.* <
1 C-BOX 100
<
DS4600A Slave 1
<
EN T
PWR-120 C-BOX 100
* P.S. (Presence Sensor) connected to External Trigger/PS input. 1
Main Serial Interface
2
Auxiliary Serial Interface
2
1
Figure 56 – RS232 Master/Slave for DS6300 Fieldbus Models
42
Page 57
INSTALLATION
2.7.4
2
Multiplexer
The Multiplexer connection is used to integrate a DS6300 slave reader in a Multidrop network consisting of different scanners not provided with a Lonworks interface. Each scanner is connected half-duplex main interface.
Multiplexer
(MX4000)
with the
RS485
P.S.*
P.S.*
<
DS4600A
<
DS6300 a
DS4600A
PWR-120
EN T
<
<
EN T
P.S.* to
CAB-600X C-BOX 100
C-BOX 100
C-BOX 100
#31
#1
#0
MX4000
1 Local Host
1 *
RS485 HD Main Interface P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 57 – Multiplexer for DS6300 Master/Slave Models
The auxiliary serial interface of the slave scanners can be used to visualize collected data or to configure it using the Genius™ utility. When On-Line operating mode is used, the scanner is activated by an External Trigger when the object enters its reading zone.
43
Page 58
DS6300
2
2.7.5
Local Lonworks Network
A local Lonworks network allows logically connecting a DS6300 master reader with up to 31 DS6300 slaves. Actually, the maximum number of readers to be employed in the network depends on the system operating conditions; that is adopted operating mode and amount of data stream. When creating your network, always keep in mind the following guidelines: • the Lonworks network logically supports a maximum number of 32 devices (master + slaves);
• it is recommended to adhere to the 8-in-16 rule (not more than 8 devices in any 16 meter bus segment;
• for DS6300 scanners the total bus length may extend up to 130 m (426 ft);
• the maximum number of DS6300 readers supported also depends on the type of power propagation adopted by the system (see the specific power supply installation manual for details).
Typically the layouts can be divided into Synchronized (single P.S.) or Multidata (multi P.S.) networks. They can be small (up to 10 scanners) or large (more than 10 scanners). Contact Datalogic Automation S.r.l. if your network requires a higher number of readers or in case the application throughput is very high. For further information on Lonworks network cabling and connections see the “LonWorks® TPT Twisted Pair Transceiver Module User’s Guide”, available from the website: www.echelon.com.
For some DS6300 Lonworks Network layouts power is propagated through the scanners. For these layouts a special setting is required in C-BOX 100 to pass scanner power to the presence sensor, encoder, etc. NOTE
44
Page 59
INSTALLATION
2
Small Synchronized Network When building a small local Lonworks network (less than 10 scanners), the DS6300 master reader must be connected to a local host computer or a C-BOX 100 by means of a CAB-60XX cable connected to the 25-pin or 26-pin D-sub male connector. The master reader connects to the first slave reader of the system through the local Lonworks 9-pin female connector. For Master/Slave models, the local Lonworks 9-pin male connector must be properly terminated by inserting the BTK-6000 Lonworks terminator. Fieldbus models are provided with an internal Lonworks terminator. The slave readers are connected together through the local Lonworks connectors. Only the 9-pin female connector of the last slave reader must be terminated by the BTK-6000 terminator. The presence sensor is connected and powered through the C-BOX 100 by the scanner and is unique to the system. There is only a single reading phase and a single message from the master reader to the Local Host. The On-Line operating mode is used for this layout.
BTK-6000
CAB-610X
CAB-60XX
C-BOX 100**
Master
Encoder***
BTK-6000 P.S.*
Local Host Slave 1
PWR-120 CAB-63XX
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power.
***
Encoder connected to IN2/ENC input. Figure 58 – Small Synchronized Network with 2 Readers
45
Page 60
DS6300
2
The following image shows a system consisting of six readers where: • the system is powered by the PWR-240 • the master and all slaves are connected together through the CAB-610X cables • the external signals (trigger, encoder, serial to host, etc.) are connected to the master through the C-BOX 100 • one or more slaves are connected through CAB-63XX. The last slave must be terminated with the BTK-6000 Slave 2
Slave1
CAB-610X
Master
CAB-610X
BTK-6000
C-BOX 100**
CAB-60XX PS*
CAB-610X
Encoder*** Host CAB-610X
CAB-610X
CAB-63XX
BTK-6000
Slave 5
Slave 4
Slave 3
PWR-240
CAB-63XX
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power.
***
Encoder connected to IN2/ENC input. Figure 59 – Small Synchronized Network with more than 2 Readers and Single Power Unit
If a single power source is used, it is not necessary to separate groups of scanners with "no power" cables (CAB-611X). NOTE
46