Page 61

INSTALLATION

2

Large Synchronized Network When building a large local Lonworks network (more than 10 scanners), an SC6000 Controller must be used together with a PWO power supply/junction box unit. In this case the SC6000 unit acts as the system master and is connected to the host through one of its interfaces. All scanners act as slaves and are connected to the SC6000 through the PWO power supply/junction box. For DS6300 scanners, a single branch connector provides Lonworks communications between the scanners and the SC6000 unit. Power is distributed evenly by connecting groups of up to 4 Slave scanners through CAB-63XX cables. The last scanner on the line requires a Termination connector. The allowed maximum bus length is 130 m. External devices such as a presence sensor and an encoder are all connected to the PWO.

** *

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

Encoder connected to ENC input. Figure 60 – Large Synchronized Network with DX6X00 and DS6XXX Scanners

47

Page 62

DS6300

2

Multidata Network In this layout, one master and up to 7 DS6300 slave readers have their own P.S. and therefore multiple reading phases. Each P.S. is connected through a C-BOX 100, which in turn is connected to its relative scanner through a CAB-60XX cable. The master sends all the individual messages collected from the Lonworks interface as well as its own to the Local Host through its C-BOX 100. The following image shows a system consisting of five readers, which are all connected together using CAB-611X cables and each scanner is individually powered by PG6000 through C-BOX 100. C-BOX 100

C-BOX 100

Host

P.S.*

P.S.*

P.S.*

PG6000

PG6000

PG6000

CAB-611X

CAB-611X

CAB-611X

CAB-611X

No power

No power

No power

No power

P.S.*

PG6000

BTK-6000

Master

*

Slave 1

Slave 2

Slave 3

P.S. (Presence Sensor) connected to External Trigger/PS input. Figure 61 – Multidata Network

48

C-BOX 100

C-BOX 100

C-BOX 100

P.S.*

PG6000

BTK-6000

Slave 4

Page 63

INSTALLATION

2.7.6

2

Fieldbus Network

The Fieldbus Ethernet model offers connectivity without any converter or adapter needed. The DS6300 master Fieldbus communicates with a remote host (for ex. remote PC connected via Internet) by means of a cable connected to the Fieldbus connector provided. It can be activated by a signal generated by the remote Host or by a physical presence sensor. The external signals (trigger, encoder) are connected to the master through the C-BOX 100. The master reader connects to the first slave reader of the system through the local Lonworks 9-pin female connector. Fieldbus models are provided with an internal Lonworks terminator. The slave readers are connected together through the local Lonworks connectors. Only the 9-pin female connector of the last slave reader must be terminated by the BTK-6000 terminator. The example below shows a system powered by the PWR-240 where multiple slaves are connected through CAB-63XX power cable. The master and all slaves are connected together through the CAB-610X cables. The same network layouts are available as for the DS6300 standard model. Remote Host

Fieldbus Network

Slave 2***

Master

Slave1***

C-BOX 100** CAB-610X

CAB-610X

CAB-60XX

CAB-610X PS* Encoder****

CAB-610X

CAB-610X

BTK-6000

CAB-63XX

PWR-240 Slave 5***

Slave 4***

Slave 3***

CAB-63XX

* ** *** ****

P.S. (Presence Sensor) connected to External Trigger/PS input. C-BOX 100 modified to accept scanner power. The Slave scanners are Master/Slave models, which allow Lonworks network propagation. Encoder connected to IN2/ENC input. Figure 62 – Fieldbus Small Synchronized Network

49

Page 64

DS6300

2

2.8 KEYPAD AND DISPLAY The DS6300 keypad allows entering a menu for selection of one of the following functions: •

Welcome: shows the current software release and operating mode;

•

Focus Adjustment:

•

Autolearn: starts the procedure making it possible to obtain an automatic, accurate and fast configuration of DS6300 without the necessity of directly checking/modifying the relevant parameters;

•

Internal Net: defines scanner function within the network (see below);

•

Ethernet Mode: allows setting the scanner IP address to be used within the network;

•

LCD Contrast: sets the LCD contrast;

•

Bus: allows setting the scanner address (value range 0-125) to be used in a Profibus network;

•

Test Mode: allows verifying the scanner reading position and features (see below).

The same settings may be performed by using the Genius™ program (see chapter 3 for details).

2.8.1

Internal Net

This submenu can be used as an alternative to configuration through Genius™, to assign the DS6300 scanner within a master/slave network. It allows defining the scanner function (slave/master) within the network and, if configured as Slave, its address. To enter the Internal Net submenu and configure the scanner follow the given procedure: 1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to enter the Main menu; 2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Internal Net” item, then press the ENT (enter) key to confirm; 3) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “LonWAddrSel”” item, then press the ENT (enter) key to confirm; 4) Use the ▲ (up arrow) or ▼ (down arrow) key to select your scanner function among “Master”, “Slave n”, “Slave jolly”, “Disabled”; then, press the ENT (enter) key to confirm; 5) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. Repeat this step again to exit the Main Menu and return to the scanner current operating mode.

50

Page 65

INSTALLATION

2.8.2

2

Test Mode

Test Mode is particularly advised during the installation phase, since it causes the reader to be continuously activated allowing to verify its reading features and its reading position with respect to the barcode. To enter the Test Mode submenu and configure the scanner follow the given procedure: 1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to enter the Main menu. 2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Test Mode” item, then press the ENT (enter) key to confirm. The reader enters Test Mode. 3) Press the ▲ (up arrow) key to exit the Test Mode. 4) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode.

2.9 FOCUS ADJUSTMENT The DS6300 provides a manual adjustment of the optics to optimize the reading performance by choosing the best focus between two extreme positions. The focus adjustment is continuous and not by step; thus, allowing an optimum adjustment around the selected position. The relative focus positions range from 0 to 100. The adjustment can be simply made through an external screw placed on the back of the optic HEAD and protected by a cap (Figure 65). The screw may be rotated either clockwise or counterclockwise in order to move the scanner internal lenses. In particular, a clockwise rotation causes a farther focus from the scanner, while a counterclockwise rotation causes a nearer focus to the scanner. An internal sensor tracks the exact laser beam focusing position allowing it to be shown on the reader display or through the Genius™ software program.

Do not stare at the laser beam output window during this operation to avoid hazardous visible laser light. WARNING

Refer to the following instructions when adjusting the focus: 1) Remove the regulation screw protecting cap (see Figure 65) positioned on the back of the optic Head; 2) Press and hold both the ▲ (up arrow) and ▼ (down arrow) key for about 2 seconds to enter the Main menu; 3) Use the ▲ (up arrow) or ▼ (down arrow) key to select “Test Mode” item, then press the ENT (enter) key to confirm. The reader enters Test Mode; 4) Press the ENT (enter) key to toggle between the graphical (default) and numerical visualization of the focus position;

51

Page 66

DS6300

2 Display Visualization

The first line of the display shows the read code and Good Read percentage. Possible suspending commas at the end of the code mean that the code is too long to be displayed. The second line of the display indicates the value of the focus position according to the table below. The indications “Too Near” or “Too Far” are represented for values outside the focus range. Graphical Visualization Numerical Visualization A |---^----------| Æ where ^ indicates the focus position Fxxx Æ where xxx ranges from 000 to 100 B N-------------| Æ where N indicates that the focus TooNear position is “Too Near”

C |--------------F Æ where F indicates that the focus Fxxx* Æ where xxx is greater than 100 position is “Too Far”

CodeRead… 100% |------^------------------|

CodeRead… 094% F034

Figure 63 – Graphical Visualization

Figure 64 – Normal Visualization

5) Rotate the focus adjustment screw to reach the desired focus position. The display is refreshed with the new values;1 6) Press the ▲ (up arrow) key to exit the Test Mode; 7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode.

Figure 65 - Focus Adjustment Screw

The reader display shows the focus position only when the laser beam is activated. NOTE

It is possible to visualize the focus position and the reading percentage on the terminal tool provided by the Genius™ configuration program (see Genius™ Help On-Line for details). 1

To avoid breakage, do not use excessive force when rotating the focus adjustment screw.