Page 41

INSTALLATION

2 DS6300 9-pin Lonworks connector pinout

Pin 1 9 2 6 3 4 5 7 8

Name CHASSIS VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B

Function Cable shield internally connected by capacitor to chassis Supply voltage - positive pin Supply voltage - negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)

Network Termination When building a Lonworks system the network must be properly terminated by positioning BTK-6000 terminator in the DS6300 master reader and in the last DS6300 slave reader. Each side of the terminator provides a different connector; thus, it can be inserted either into the Lonworks 9-pin male connector of the master reader or in the Lonworks 9-pin female connector of the last slave reader: Slave

Master

Male Female

Female Male

Figure 33 - BTK-6000 Network Terminator

For Fieldbus models no terminator must be inserted in the reader, since it is internally integrated. NOTE

27

Page 42

DS6300

2

Lonworks Interface The Lonworks network is used for both input and output connection to build a multi-sided or omni-station system connecting several readers. The DS6300 master usually employs the 9-pin female connector for output connection to the first slave, while the 9-pin male one is terminated by inserting the BTK6000 terminator (see par. 2.7.2 for details). If creating a T-network configuration, it is necessary to use both connectors to create the double branch line of slave readers. Both connectors are always employed when connecting together the slave readers. In particular, the 9-pin female connector is used for output connection and the male one for input connection. The female connector is always terminated in the last slave reader to close the system network. The following diagram represents the connection between a DS6300-XXX-010 working as master and a DS6300-XXX-010 working as a slave reader. The cable shield for LON A/B is connected to pin 1 - CHASSIS. Master

Slave

VS_I/O

4

4

5

5

3

3

LON A

7

7

REF_I/O

LON B

8

8

CHASSIS

1

1

VS

9

AWG 16

9

GND

2

AWG 16

2

CHASSIS

= male connector = female connector

Figure 34 – DS6300-XXX-010 Master/Slave Lonworks Connection

CAUTION

The maximum current to be propagated to the slave readers through the master is 2 A. For this reason, it is suggested the use of a 24 V power supply allowing to supply up to three readers (master + 2 slaves).

The following diagrams represent different network terminations using the BTK-6000 terminator. In each diagram the terminator is indicated by the element, while the figure below shows its electrical circuit in details:

Figure 35 – BTK-6000 Electrical Circuit

28

Page 43

INSTALLATION

2

The diagram below represents the termination of a DS6300-XXX-010 working as master by means of the BTK-6000 terminator. BTK-6000 Female Side

Master VS

9

9

VS_I/O

6

6

LON A

7

7

LON B

8

8

GND

2

2

REF_I/O

3

3

T

= male connector = female connector

Figure 36 – DS6300-XXX-010 Master Termination

The diagram below represents the termination of a DS6300-XXX-010 working as slave by means of the BTK-6000 terminator. Slave

BTK-6000 Male Side

LON A

7

7

LON B

8

8

T

= male connector = female connector

Figure 37 – DS6300-XXX-010 Slave Termination

The diagram below represents the connection between a DS6300 Fieldbus model, which always works as master, and a DS6300-XXX-010 working as a slave reader. Fieldbus Master

Slave

VS_I/O

4

4

5

5

3

3

LON A

7

7

LON B

8

8

CHASSIS

1

1

VS

9

AWG 16

9

GND

2

AWG 16

2

REF_I/O

T

CHASSIS

= male connector = female connector

Figure 38 – DS6300-XXX-010 Master/Slave Lonworks Connection

29

Page 44

DS6300

2

2.3.3

Ethernet Connector

This connector is only available for DS6300 Ethernet models and allows the Ethernet connection between the host and the scanner.

8

1

Figure 39 – Cable RJ45 Male Modular Connector

1

8

Figure 40 – DS6300 RJ45 Female Modular Connector

This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT and IEEE 802.3u 100 BaseTx compliant. RJ45 Modular Jack Pinout Pin 1 2 3 6 4, 5, 7, 8

Name TX + TX RX + RX N.C.

Function Transmitted data (+) Transmitted data (-) Received data (+) Received data (-) Not connected

In order to meet EMC requirements: • use Eth shielded cable

• connect the Ethernet interface cable shield to the plant earth ground

The cable shield must be connected to the chassis of both connectors. A ferrite (type Stewart 28A2029-0A0) may also be applied on the scanner side of the Ethernet cable to reduce electrical noise. NOTE

30

Page 45

INSTALLATION

2

Ethernet Interface The Ethernet interface (NIC) can be used for TCP/IP communication with remote or local host computer by connecting the scanner to a LAN as well as with a host PC directly connected to the scanner. The following is an example of a connection to a LAN through a Hub using a straight through cable: HUB / SWITCH

DS6300 TX+

1

1

TX-

2

2

RX+

3

3 n. c.

4

4 n. c.

5

5

RX-

6

6 n. c.

7

7 n. c.

8

8 n. c. = not connected

Figure 41 – Straight Through Cable

The following is an example of direct connection to a PC using an inverted cable: Host PC

DS6300 1

3

2

6

3

1

4

4

5

5

6

2

7

7

8

8

Figure 42 – Inverted Cable

For further details refer to the “Ethernet Service Guide" document provided as supplementary documentation.

31

Page 46

DS6300

2

2.3.4

DeviceNet Connector

When using DeviceNet, the Main serial interface is disabled and must not be physically connected. NOTE

The 5-pin male connector is only available in the DS6300 DeviceNet model and allows connection between the host and the reader:

4

3

1

2

5

Figure 43 - DeviceNet 5-pin Male Connector

DS6300 5-pin DeviceNet connector pinout Pin 2 5 1 4 3

NOTE

32

Name V+ CAN_L SHIELD CAN_H V-

Function Supply voltage – positive pin CAN bus data line – L Shield CAN bus data line – H Supply voltage – negative pin

The power supplied on pin V+ and V- is used only to propagate power to the section of the DeviceNet board directly connected to the Bus. It is completely isolated from the DS6300 power which must be supplied on pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.

Page 47

INSTALLATION

2.3.5

2

Profibus Connector

The 9-pin female Profibus connector (white) is only available in the DS6300 Profibus model and allows connection between the host and the reader: 1

5

9

6

Figure 44 - Profibus 9-pin Female Connector

DS6300 9-pin Profibus connector pinout Pin 1 2 3 4 5 6 7 8 9

Name Shield* Free B-LINE (RxD/TxD-P) CNTR-P** DGND +5 V Free A-LINE (RxD/TxD-N) CNTR-N**

* signal is optional

** signal is optional; RS485 level

Function Shield, Protective Ground resp. Received/Transmitted Data-P Repeater Control Signal Data Ground (M5V) Voltage Plus (P5V) Received/Transmitted Data Repeater Control Signal

Profibus Interface The Profibus interface is used for communication with an Host and allows expanding the networking and remote diagnostic capabilities of the scanner. For further details refer to the “Profibus_Fam6k.pdf” document provided as supplementary documentation.

33

Page 48

DS6300

2

2.3.6

Power Supply

The supply voltage of a single scanner must be between 15 and 30 VDC. Datalogic strongly recommends a minimum 24 VDC supply voltage when using a master/slave configuration. The power consumption of the different DS6300 models is slightly different. In particular, when connecting several DS6300 readers in a master/slave connection, the typical power consumption for each scanner is 15 W. There is a power peak of about 20 W lasting 5..10 seconds caused by the motor starting. A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from the power on of the scanner. Note that GND is internally connected to chassis. The cable shield is also connected to pin 1 - CHASSIS. DS6300

USER INTERFACE 9/13

VS

23/25

GND

1

CHASSIS

V+ (15 – 30 Vdc) V- (Ground)

Chassis

Earth Ground

Figure 45 – Power Supply Using the 25/26-pin Connector

2.4 USER INTERFACE RS232 PC-side connections 5

1

6

9

9-pin male connector

Pin 2 3 5 7 8

34

Name RX TX GND RTS CTS

1

13

14

25

25-pin male connector

Pin 3 2 7 4 5

Name RX TX GND RTS CTS

Page 49

INSTALLATION

2

How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 25-pin D-sub female

9-pin D-sub female

21

TXAUX

2

RX

20

RXAUX

3

TX

5

GND

23 GND

PC

13 VS 25 GND

DS6300

9

VS

18 EXT TRIG A 19 EXT TRIG B

Power Supply VS (15 – 30 VDC) Power GND

Trigger

Test Cable for DS6300

2.5 POSITIONING THE SCANNER The DS6300 reader is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting DS6300 take into consideration these three ideal label position angles: Pitch 0°, Skew 10° to 30° and Tilt 0°. Follow the suggestions for the best orientation: The Pitch angle is represented by the value P in Figure 46. Position the reader in order to minimize the Pitch angle. P

Figure 46 - "Pitch" Angle

35

Page 50

DS6300

2

The Skew angle is represented by the value S in Figure 47. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the scanner. For oscillating mirror models, this angle refers to the most inclined or external laser line, so that all other laser lines assure more than 10° Skew.

S

Figure 47 - "Skew" Angle

The Tilt angle is represented by the value T in Figure 48. T

Figure 48 - "Tilt" Angle

36