The text of a manual · part 2 of 4
DS6300 Quick Reference Guide, pages 11 to 20
Pages 11 to 20 of 39
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-6300
Page 11
DS6300 PROFIBUS MODEL SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 standard Codabar Code 128 EAN 128 Code 93 (Standard & Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and128Terminators byte terminators Operating On Line, Automatic, Test Modes Config. Mode Genius™ utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Dimensions mm (inch) Weight
Std Models 110x113x99 (4.33x4.45x3.9)
Oscill. Mirror 113x180x104.5 (4.45x7.08x4.11)
1.5 kg (3.3 lb)
2.0 kg (4.4 lb)
ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature -20° to +70 °C Storage Temperature (-4° to +158 °F) Humidity 90% non condensing Ambient Light 3500 lux Immunity Vibration Resistance 14mm @ 2 to 10Hz IEC 68-2-6 test FC 1.5 mm @13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30 g; 11 ms IEC 68-2-27 test EA 3 shocks on each axis IP64 Protection Class
Accessories: Name CAB-6011 CAB-6012 CAB-6015 C-BOX 100 INT-30 GFC-60 GFC-600 GFX-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 US-60 PH-1 MEP-543 OEK-2 OEK-1
Description Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Passive connection box 20 mA C.L. interface board for C-BOX 100 90° mirror 90° mirror close distance X-pattern mirror Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Mounting bracket kit (5 pcs) for multisided stations Photocell kit - PNP Photocell kit – NPN Optical encoder (10 m cable + spring) Optical encoder kit + 10 m cable
Part Number 93A051221 93A051222 93A051223 93ACC1510 93A151022 93A201100 93A201102 93ACC1730 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 93ACC1791 93ACC1728 93ACC1770 93ACC1600
Electrical Connections: The DS6300 Profibus reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An 9-pin Profibus connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector connects the Profibus master to the first slave reader of the system. The details of the connector pins are indicated in the following table:
9
Page 12
DS6300 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin
Name
Function
Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 9 1 16 OUT 3A Configurable digital output 3 – polarity insensitive 10 18 19 17 OUT 3B Configurable digital output 3 – polarity insensitive 26 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 26-pin male D-sub Connector 19 EXT_TRIG/PS B External trigger (polarity insensitive)for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin 1
*
CHASSIS
Pin
RS232
RS485 Full-Duplex
RS485 Half-Duplex
2 3 4 5 7
TX RX RTS CTS GND_ISO
TX485+ * RX485+ TX485* RX485GND_ISO
RTX485+
20 mA C.L. (INT-30 with C-BOX 100 only)
see INT-30 instructions
RTX485GND_ISO
Do not leave floating, see Reference Manual for connection details.
9-pin Lonworks Connector Pinout Pin
Name
1
CHASSIS
9 2 6 3 4 5 7 8
VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B
Function Cable shield internally connected by capacitor to chassis Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)
1
5
9
6
9-pin female Local Lonworks Connector
9-pin Profibus Connector Pin 1 2 3 4 5 6 7 8 9
10
Name Shield Free B-LINE (RxD/TxD-P) CNTR-P DGND +5 V Free A-LINE (RxD/TxD-N) CNTR-N
Function Shield, Protective Ground resp. (optional) Received/Transmitted Data-P Repeater Control Signal (optional, RS485 level) Data Ground (M5V) Voltage Plus (P5V) Received/Transmitted Data Repeater Control Signal
1
5
9
6
9-pin female Profibus Connector (white)
Page 13
DS6300 PROFIBUS MODEL
Connectivity: Point-to-Point Layout Remote Host
Fieldbus Network DS6300 C-BOX 100 CAB-601X
*P.S PG6000
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
Pass Through Layout Remote Host
*P.S.
*P.S. Gryphon
DS4600A
<
<
EN T
CAB-601X
C-BOX 100 AUX
DS4600A
EN T
<
DS6300
<
Fieldbus Network
C-BOX 100
C-BOX 100
*P.S.
2
1
2
1
PWR-120
1 Main Serial Interface
*
2 Auxiliary Serial Interface
P.S. (Presence Sensor) connected to External Trigger/PS input.
11
Page 14
DS6300 PROFIBUS MODEL Local Lonworks Network Remote Host
Fieldbus Network
Slave 2***
Slave 1***
Master
C-BOX 100** CAB-610X
CAB-610X
CAB-60XX
P.S.*
CAB-610X
Encoder**** CAB-610X
CAB-610X
CAB-63XX
BTK-6000
Slave 5***
Slave 3***
Slave 4***
PWR-240
CAB-63XX
Fieldbus Small Synchronized Network
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power.
***
The Slave scanners are Master/Slave models, which allow Lonworks network propagation.
****
Encoder connected to IN2/ENC input.
12
Page 15
DS6300 ETHERNET MODEL
DS6300-100-012 ETHERNET MODEL
1
Figure A 1 Laser Beam Output Window
3
5
1 3
4
1
2
2
Figure B
Figure C
1 Programming Keypad
4 Power On LED (Red)
1 RJ45 Modular Connector for Ethernet Interface
2 TX Data LED (Green)
5 LCD Display
2 Lonworks 9-pin Female Connector
3 Phase On LED (Yellow)
3 Main/Aux. Interface 26-pin D-Sub Male Connector
Available Models: DS6500 - 10X - 0YY Decoder Model Optical Model
10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet
0 = Standard 5 = Oscillating Mirror
Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only)
Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs
Laser Control
1200 to 115200 19200
Auxiliary RS232 Other
1200 to 115200
Lonworks
1.25 Mb/s
Ethernet
10 or 100 Mb/s
(optocoupled NPN or PNP)
(optocoupled)
OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class IICDRH Security system to turn laser off in case of motor slow down
READING FEATURES Scan Rate 600-1200 scans/s
Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field
USER INTERFACE LCD Display Keypad LED Indicators
(see reading diagram)
2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)
13
Page 16
DS6300 ETHERNET MODEL SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 standard Codabar Code 128 EAN 128 Code 93 (Standard & Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and128Terminators byte terminators Operating On Line, Automatic, Test Modes Config. Mode Genius™ utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Dimensions mm (inch) Weight
Std Models 110x113x99 (4.33x4.45x3.9)
Oscill. Mirror 113x180x104.5 (4.45x7.08x4.11)
1.5 kg (3.3 lb)
2.0 kg (4.4 lb)
ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature -20° to +70 °C Storage Temperature (-4° to +158 °F) Humidity 90% non condensing Ambient Light 3500 lux Immunity Vibration Resistance 14mm @ 2 to 10Hz IEC 68-2-6 test FC 1.5 mm @13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30 g; 11 ms IEC 68-2-27 test EA 3 shocks on each axis IP50 Protection Class
Accessories: Name CAB-6011 CAB-6012 CAB-6015 C-BOX 100 INT-30 GFC-60 GFC-600 GFX-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 US-60 PH-1 MEP-543 OEK-2 OEK-1
Description Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Passive connection box 20 mA C.L. interface board for C-BOX 100 90° mirror 90° mirror close distance X-pattern mirror Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Mounting bracket kit (5 pcs) for multisided stations Photocell kit - PNP Photocell kit – NPN Optical encoder (10 m cable + spring) Optical encoder kit + 10 m cable
Part Number 93A051221 93A051222 93A051223 93ACC1510 93A151022 93A201100 93A201102 93ACC1730 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 93ACC1791 93ACC1728 93ACC1770 93ACC1600
Electrical Connections: The DS6300 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system. The details of the connector pins are indicated in the following table:
14
Page 17
DS6300 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin
Name
Function
Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 9 1 16 OUT 3A Configurable digital output 3 – polarity insensitive 10 18 19 17 OUT 3B Configurable digital output 3 – polarity insensitive 26 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 26-pin male D-sub Connector 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin 1
*
CHASSIS
Pin
RS232
RS485 Full-Duplex
RS485 Half-Duplex
2 3 4 5 7
TX RX RTS CTS GND_ISO
TX485+ * RX485+ TX485* RX485GND_ISO
RTX485+
20 mA C.L. (INT-30 with C-BOX 100 only)
see INT-30 instructions
RTX485GND_ISO
Do not leave floating, see Reference Manual for connection details. 9-pin Lonworks Connector Pinout Pin
Name
1
CHASSIS
9 2 6 3 4 5 7 8
VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B
Function Cable shield internally connected by capacitor to chassis Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)
1
5
9
6
9-pin female Local Lonworks Connector
RJ45 Modular Connector HUB / SWITCH
DS6300 TX+
1
1
TX-
2
2
RX+
3
3 n. c.
4
4 n. c.
5
5
RX-
6
6 n. c.
7
7 n. c.
8
8
1
8
RJ45 Modular Connector n. c. = not connected
15
Page 18
DS6300 ETHERNET MODEL
Connectivity: Point-to-Point Layout Remote Host
Fieldbus Network DS6300 C-BOX 100 CAB-601X
*P.S PG6000
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
Pass Through Layout Remote Host
*P.S.
*P.S. Gryphon
DS4600A
<
<
EN T
CAB-601X
C-BOX 100 AUX
C-BOX 100
C-BOX 100
*P.S.
2
1
PWR-120
1 Main Serial Interface
*
16
2 Auxiliary Serial Interface
P.S. (Presence Sensor) connected to External Trigger/PS input.
DS4600A
EN T
<
DS6300
<
Fieldbus Network
2
1
Page 19
DS6300 ETHERNET MODEL Local Lonworks Network Remote Host
Fieldbus Network
Slave 2***
Slave 1***
Master
C-BOX 100** CAB-610X
CAB-610X
CAB-60XX
P.S.*
CAB-610X
Encoder**** CAB-610X
CAB-610X
CAB-63XX
BTK-6000
Slave 5***
Slave 3***
Slave 4***
PWR-240
CAB-63XX
Fieldbus Small Synchronized Network
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power.
***
The Slave scanners are Master/Slave models, which allow Lonworks network propagation.
****
Encoder connected to IN2/ENC input.
17
Page 20
DS6300 DEVICENET MODEL
DS6300-100-015 DEVICENET MODEL
1
Figure A 1 Laser Beam Output Window
1 5
1 3
4
3
2
2
Figure B
Figure C
1 Programming Keypad
4 Power On LED (Red)
2 TX Data LED (Green)
5 LCD Display
1 Main/Aux. Interface 26-pin D-sub Male Connector 2 Lonworks 9-pin Female Connector 3 DeviceNet 5-pin Male Connector
3 Phase On LED (Yellow)
Available Models: DS6300 - 10X - 0YY Decoder Model
Optical Model
10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet
0 = Standard 5 = Oscillating Mirror
Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only)
1200 to 115200 19200
Auxiliary RS232
1200 to 115200
Other Lonworks
1.25 Mb/s
DeviceNet
125 or 250 Kb/s
Inputs Ext. Trigger 1, 3 aux. digital inputs (optocoupled NPN or PNP) Outputs 3 software programmable digital outputs
18
(optocoupled)
OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class II-CDRH Laser Control Security system to turn laser off in case of motor slow down READING FEATURES Scan Rate 600-1200 scans/s Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field USER INTERFACE LCD Display Keypad LED Indicators
(see reading diagram)
2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)