Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 4

DS6300 Quick Reference Guide, pages 11 to 20

Pages 11 to 20 of 39

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-6300

Page 11

DS6300 PROFIBUS MODEL SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 standard Codabar Code 128 EAN 128 Code 93 (Standard & Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and128Terminators byte terminators Operating On Line, Automatic, Test Modes Config. Mode Genius™ utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Dimensions mm (inch) Weight

Std Models 110x113x99 (4.33x4.45x3.9)

Oscill. Mirror 113x180x104.5 (4.45x7.08x4.11)

1.5 kg (3.3 lb)

2.0 kg (4.4 lb)

ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature -20° to +70 °C Storage Temperature (-4° to +158 °F) Humidity 90% non condensing Ambient Light 3500 lux Immunity Vibration Resistance 14mm @ 2 to 10Hz IEC 68-2-6 test FC 1.5 mm @13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30 g; 11 ms IEC 68-2-27 test EA 3 shocks on each axis IP64 Protection Class

Accessories: Name CAB-6011 CAB-6012 CAB-6015 C-BOX 100 INT-30 GFC-60 GFC-600 GFX-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 US-60 PH-1 MEP-543 OEK-2 OEK-1

Description Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Passive connection box 20 mA C.L. interface board for C-BOX 100 90° mirror 90° mirror close distance X-pattern mirror Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Mounting bracket kit (5 pcs) for multisided stations Photocell kit - PNP Photocell kit – NPN Optical encoder (10 m cable + spring) Optical encoder kit + 10 m cable

Part Number 93A051221 93A051222 93A051223 93ACC1510 93A151022 93A201100 93A201102 93ACC1730 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 93ACC1791 93ACC1728 93ACC1770 93ACC1600

Electrical Connections: The DS6300 Profibus reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An 9-pin Profibus connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector connects the Profibus master to the first slave reader of the system. The details of the connector pins are indicated in the following table:

9

Page 12

DS6300 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin

Name

Function

Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 9 1 16 OUT 3A Configurable digital output 3 – polarity insensitive 10 18 19 17 OUT 3B Configurable digital output 3 – polarity insensitive 26 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 26-pin male D-sub Connector 19 EXT_TRIG/PS B External trigger (polarity insensitive)for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin 1

*

CHASSIS

Pin

RS232

RS485 Full-Duplex

RS485 Half-Duplex

2 3 4 5 7

TX RX RTS CTS GND_ISO

TX485+ * RX485+ TX485* RX485GND_ISO

RTX485+

20 mA C.L. (INT-30 with C-BOX 100 only)

see INT-30 instructions

RTX485GND_ISO

Do not leave floating, see Reference Manual for connection details.

9-pin Lonworks Connector Pinout Pin

Name

1

CHASSIS

9 2 6 3 4 5 7 8

VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B

Function Cable shield internally connected by capacitor to chassis Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)

1

5

9

6

9-pin female Local Lonworks Connector

9-pin Profibus Connector Pin 1 2 3 4 5 6 7 8 9

10

Name Shield Free B-LINE (RxD/TxD-P) CNTR-P DGND +5 V Free A-LINE (RxD/TxD-N) CNTR-N

Function Shield, Protective Ground resp. (optional) Received/Transmitted Data-P Repeater Control Signal (optional, RS485 level) Data Ground (M5V) Voltage Plus (P5V) Received/Transmitted Data Repeater Control Signal

1

5

9

6

9-pin female Profibus Connector (white)

Page 13

DS6300 PROFIBUS MODEL

Connectivity: Point-to-Point Layout Remote Host

Fieldbus Network DS6300 C-BOX 100 CAB-601X

*P.S PG6000

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

Pass Through Layout Remote Host

*P.S.

*P.S. Gryphon

DS4600A

<

<

EN T

CAB-601X

C-BOX 100 AUX

DS4600A

EN T

<

DS6300

<

Fieldbus Network

C-BOX 100

C-BOX 100

*P.S.

2

1

2

1

PWR-120

1 Main Serial Interface

*

2 Auxiliary Serial Interface

P.S. (Presence Sensor) connected to External Trigger/PS input.

11

Page 14

DS6300 PROFIBUS MODEL Local Lonworks Network Remote Host

Fieldbus Network

Slave 2***

Slave 1***

Master

C-BOX 100** CAB-610X

CAB-610X

CAB-60XX

P.S.*

CAB-610X

Encoder**** CAB-610X

CAB-610X

CAB-63XX

BTK-6000

Slave 5***

Slave 3***

Slave 4***

PWR-240

CAB-63XX

Fieldbus Small Synchronized Network

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

The Slave scanners are Master/Slave models, which allow Lonworks network propagation.

****

Encoder connected to IN2/ENC input.

12

Page 15

DS6300 ETHERNET MODEL

DS6300-100-012 ETHERNET MODEL

1

Figure A 1 Laser Beam Output Window

3

5

1 3

4

1

2

2

Figure B

Figure C

1 Programming Keypad

4 Power On LED (Red)

1 RJ45 Modular Connector for Ethernet Interface

2 TX Data LED (Green)

5 LCD Display

2 Lonworks 9-pin Female Connector

3 Phase On LED (Yellow)

3 Main/Aux. Interface 26-pin D-Sub Male Connector

Available Models: DS6500 - 10X - 0YY Decoder Model Optical Model

10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet

0 = Standard 5 = Oscillating Mirror

Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only)

Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs

Laser Control

1200 to 115200 19200

Auxiliary RS232 Other

1200 to 115200

Lonworks

1.25 Mb/s

Ethernet

10 or 100 Mb/s

(optocoupled NPN or PNP)

(optocoupled)

OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class IICDRH Security system to turn laser off in case of motor slow down

READING FEATURES Scan Rate 600-1200 scans/s

Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field

USER INTERFACE LCD Display Keypad LED Indicators

(see reading diagram)

2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)

13

Page 16

DS6300 ETHERNET MODEL SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 standard Codabar Code 128 EAN 128 Code 93 (Standard & Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and128Terminators byte terminators Operating On Line, Automatic, Test Modes Config. Mode Genius™ utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Dimensions mm (inch) Weight

Std Models 110x113x99 (4.33x4.45x3.9)

Oscill. Mirror 113x180x104.5 (4.45x7.08x4.11)

1.5 kg (3.3 lb)

2.0 kg (4.4 lb)

ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32 to +104 °F) Temperature -20° to +70 °C Storage Temperature (-4° to +158 °F) Humidity 90% non condensing Ambient Light 3500 lux Immunity Vibration Resistance 14mm @ 2 to 10Hz IEC 68-2-6 test FC 1.5 mm @13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30 g; 11 ms IEC 68-2-27 test EA 3 shocks on each axis IP50 Protection Class

Accessories: Name CAB-6011 CAB-6012 CAB-6015 C-BOX 100 INT-30 GFC-60 GFC-600 GFX-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 US-60 PH-1 MEP-543 OEK-2 OEK-1

Description Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Passive connection box 20 mA C.L. interface board for C-BOX 100 90° mirror 90° mirror close distance X-pattern mirror Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Mounting bracket kit (5 pcs) for multisided stations Photocell kit - PNP Photocell kit – NPN Optical encoder (10 m cable + spring) Optical encoder kit + 10 m cable

Part Number 93A051221 93A051222 93A051223 93ACC1510 93A151022 93A201100 93A201102 93ACC1730 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 93ACC1791 93ACC1728 93ACC1770 93ACC1600

Electrical Connections: The DS6300 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system. The details of the connector pins are indicated in the following table:

14

Page 17

DS6300 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin

Name

Function

Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 9 1 16 OUT 3A Configurable digital output 3 – polarity insensitive 10 18 19 17 OUT 3B Configurable digital output 3 – polarity insensitive 26 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 26-pin male D-sub Connector 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin 1

*

CHASSIS

Pin

RS232

RS485 Full-Duplex

RS485 Half-Duplex

2 3 4 5 7

TX RX RTS CTS GND_ISO

TX485+ * RX485+ TX485* RX485GND_ISO

RTX485+

20 mA C.L. (INT-30 with C-BOX 100 only)

see INT-30 instructions

RTX485GND_ISO

Do not leave floating, see Reference Manual for connection details. 9-pin Lonworks Connector Pinout Pin

Name

1

CHASSIS

9 2 6 3 4 5 7 8

VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B

Function Cable shield internally connected by capacitor to chassis Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)

1

5

9

6

9-pin female Local Lonworks Connector

RJ45 Modular Connector HUB / SWITCH

DS6300 TX+

1

1

TX-

2

2

RX+

3

3 n. c.

4

4 n. c.

5

5

RX-

6

6 n. c.

7

7 n. c.

8

8

1

8

RJ45 Modular Connector n. c. = not connected

15

Page 18

DS6300 ETHERNET MODEL

Connectivity: Point-to-Point Layout Remote Host

Fieldbus Network DS6300 C-BOX 100 CAB-601X

*P.S PG6000

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

Pass Through Layout Remote Host

*P.S.

*P.S. Gryphon

DS4600A

<

<

EN T

CAB-601X

C-BOX 100 AUX

C-BOX 100

C-BOX 100

*P.S.

2

1

PWR-120

1 Main Serial Interface

*

16

2 Auxiliary Serial Interface

P.S. (Presence Sensor) connected to External Trigger/PS input.

DS4600A

EN T

<

DS6300

<

Fieldbus Network

2

1

Page 19

DS6300 ETHERNET MODEL Local Lonworks Network Remote Host

Fieldbus Network

Slave 2***

Slave 1***

Master

C-BOX 100** CAB-610X

CAB-610X

CAB-60XX

P.S.*

CAB-610X

Encoder**** CAB-610X

CAB-610X

CAB-63XX

BTK-6000

Slave 5***

Slave 3***

Slave 4***

PWR-240

CAB-63XX

Fieldbus Small Synchronized Network

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

The Slave scanners are Master/Slave models, which allow Lonworks network propagation.

****

Encoder connected to IN2/ENC input.

17

Page 20

DS6300 DEVICENET MODEL

DS6300-100-015 DEVICENET MODEL

1

Figure A 1 Laser Beam Output Window

1 5

1 3

4

3

2

2

Figure B

Figure C

1 Programming Keypad

4 Power On LED (Red)

2 TX Data LED (Green)

5 LCD Display

1 Main/Aux. Interface 26-pin D-sub Male Connector 2 Lonworks 9-pin Female Connector 3 DeviceNet 5-pin Male Connector

3 Phase On LED (Yellow)

Available Models: DS6300 - 10X - 0YY Decoder Model

Optical Model

10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet

0 = Standard 5 = Oscillating Mirror

Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only)

1200 to 115200 19200

Auxiliary RS232

1200 to 115200

Other Lonworks

1.25 Mb/s

DeviceNet

125 or 250 Kb/s

Inputs Ext. Trigger 1, 3 aux. digital inputs (optocoupled NPN or PNP) Outputs 3 software programmable digital outputs

18

(optocoupled)

OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class II-CDRH Laser Control Security system to turn laser off in case of motor slow down READING FEATURES Scan Rate 600-1200 scans/s Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field USER INTERFACE LCD Display Keypad LED Indicators

(see reading diagram)

2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)