Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 4

DS6300 Quick Reference Guide, pages 1 to 10

Pages 1 to 10 of 39

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-6300

Page 1 read from a scan by OCR; it may hold reading errors

~JATALOGIC..

DS6300

QUICK REFERENCE GUIDE

Page 2

CONTENTS DS6300-100-010 MASTER/SLAVE MODEL ...........................................................................................................1 DS6300-100-011 PROFIBUS MODEL.....................................................................................................................8 DS6300-100-012 ETHERNET MODEL ..................................................................................................................13 DS6300-100-015 DEVICENET MODEL.................................................................................................................18 DS6300-105-0XX OSCILLATING MIRROR MODEL.............................................................................................23 COMMON FEATURES ..........................................................................................................................................25

For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product. NOTE

SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information including:

•

PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - Genius™ a utility program, which allows device configuration using a PC. It provides RS232 interface configuration.

•

SERVICES & SUPPORT - Datalogic Services - Warranty Extensions and Maintenance Agreements - Authorised Repair Centres

•

CONTACT US E-mail form and listing of Datalogic Subsidiaries

Page 3

DS6300 MASTER/SLAVE MODEL

DS6300-100-010 MASTER/SLAVE MODEL

1

Figure A 1 Laser Beam Output Window

1

5

1 3

4

3

2

2

Figure B

Figure C

1 Programming Keypad

4 Power On LED (Red)

1 Main/Aux. Interface 25-pin D-sub Male Connector

2 TX Data LED (Green)

5 LCD Display

2 Lonworks 9-pin Male Connector

3 Phase On LED (Yellow)

3 Lonworks 9-pin Female Connector

Available Models: DS6300 - 10X - 0YY Decoder Model

Optical Model

10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet

0 = Standard 5 = Oscillating Mirror

Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only)

Auxiliary RS232 Other Lonworks

Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs

Laser Control

1200 to 115200 19200 1200 to 11520 1.25 Mb/s

(optocoupled NPN or PNP)

(optocoupled)

OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class II-CDRH Security system to turn laser off in case of motor slow down

READING FEATURES Scan Rate 600-1200 scans/s Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field USER INTERFACE LCD Display Keypad LED Indicators

(see reading diagram)

2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)

1

Page 4

DS6300 MASTER/SLAVE MODEL SOFTWARE FEATURES Readable Codes Interleaved 2/5 Code 39 standard Codabar Code 128 EAN 128 Code 93 (Standard & Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code Selection Up to 10 codes during one reading phase Headers and Up to 128-byte headers and128Terminators byte terminators Operating On Line, Automatic, Test Modes Config. Mode Genius™ utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Dimensions mm (inch) Weight

Std Models 110x113x99 (4.33x4.45x3.9)

Oscill. Mirror 113x180x104.5 (4.45x7.08x4.11)

1.5 kg (3.3 lb)

2.0 kg (4.4 lb)

ENVIRONMENTAL FEATURES Operating 0° to +40 °C (+32° to +104 °F) Temperature -20° to +70 °C Storage Temperature (-4° to +158 °F) Humidity 90% non condensing Ambient Light 3500 lux Immunity Vibration Resistance 14mm @ 2 to 10Hz IEC 68-2-6 test FC 1.5 mm @13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis Shock Resistance 30 g; 11 ms IEC 68-2-27 test EA 3 shocks on each axis IP64 Protection Class

Accessories: Name CAB-6001 CAB-6002 CAB-6005 CAB-6010 CAB-6101 CAB-6102 CAB-6105 CAB-6112 CAB-6115 CAB-6305 CAB-6310 C-BOX 100 INT-30 GFC-60 GFC-600 GFX-60 PWR-120 BTK-6000 PG6002 PG6001 PG6000 FBK-6000 US-60 PH-1 MEP-543 OEK-2 OEK-1

Description Cable to C-BOX100 1 m Cable to C-BOX100 2 m Cable to C-BOX100 5 m Cable to C-BOX100 10 m Cable master/slave 1 m Cable master/slave 2 m Cable master/slave 5 m Cable master/slave no power 2 m Cable master/slave no power 5 m Power cable Fam 6k 5 m Power cable Fam 6k 10 m Passive connection box 20 mA C.L. interface board for C-BOX 100 90° mirror 90° mirror close distance X-pattern mirror Power unit 110/230 V AC - 24 V DC Terminator kit (5 pcs) Single unit power supply – US Single unit power supply – UK Single unit power supply – EU Fast bracket kit (2 pcs) Mounting bracket kit (5 pcs) for multisided stations Photocell kit - PNP Photocell kit - NPN Optical encoder (10 m cable + spring) Optical encoder kit + 10 m cable

Part Number 93A051190 93A051200 93A051210 93A051271 93A051220 93A051230 93A051240 93A051224 93A051225 93ACC1768 93ACC1752 93ACC1510 93A151022 93A201100 93A201102 93ACC1730 93ACC1530 93ACC1710 93ACC1718 93ACC1719 93ACC1720 93ACC1721 93ACC1729 93ACC1791 93ACC1728 93ACC1770 93ACC1600

Electrical Connections: The DS6300 reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. Two 9-pin connectors provide access to the scanner’s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system.

2

Page 5

DS6300 MASTER/SLAVE MODEL The details of the connector pins are indicated in the following table: 25-pin D-Sub Connector Pinout Pin

Name

Function

Chassis - internally connected to GND Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 16 OUT 3A Configurable digital output 3 – polarity insensitive 17 OUT 3B Configurable digital output 3 – polarity insensitive 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25 GND Supply voltage – negative pin 1

*

CHASSIS

13

1

25

14

25-pin male D-sub Connector

Pin

RS232

RS485 Full-Duplex

RS485 Half-Duplex

2 3 4 5 7

TX RX RTS CTS GND_ISO

TX485+ * RX485+ TX485* RX485GND_ISO

RTX485+

20 mA C.L. (INT-30 with C-BOX 100 only)

see INT-30 instructions

RTX485GND_ISO

Do not leave floating, see Reference Manual for connection details.

9-pin Lonworks Connector Pinout Pin

Name

1

CHASSIS

9 2 6 3 4 5 7 8

VS GND VS_I/O Ref_I/O SYS_ENC_I/O SYS_I/O LON A LON B

Function Cable shield internally connected by capacitor to chassis Supply voltage – positive pin Supply voltage – negative pin Supply voltage of I/O circuit Reference voltage of I/O circuit System signal System signal Lonworks line (polarity insensitive) Lonworks line (polarity insensitive)

1

5

9

6

Female

5

1

6

9

Male

9-pin Local Lonworks Connectors

Network Termination: When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000 terminator on the DS6300 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male side). to Master to Slave

9-pin female

9-pin male

BTK-6000 Network Terminator

3

Page 6

DS6300 MASTER/SLAVE MODEL

Connectivity: Point-to-Point Layout DS6300 CAB-600X

C-BOX 100

Local Host *P.S.

PG6000

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

Pass Through Layout *P.S.

*P.S.

Gryphon

DS4600A

<

T

<

<

EN

CAB-600X

C-BOX 100

C-BOX 100

C-BOX 100

AUX MAIN

*P.S.

1

2

2

Local Host

1

PWR-120

1 Main Serial Interface *

4

DS4600A

EN T

<

DS6300

2 Auxiliary Serial Interface

P.S. (Presence Sensor) connected to External Trigger/PS input.

1

Page 7

DS6300 MASTER/SLAVE MODEL Multiplexer Layout *P.S.

*P.S.

*P.S.

DS4600A

<

DS4600A

<

DS6300

EN T

EN T

<

<

PWR-120

CAB-600X

C-BOX 100

C-BOX 100

C-BOX 100

#31

MX4000

1

#0

#1

Local Host

1 RS485 HD Main Interface *

P.S. (Presence Sensor) connected to External Trigger/PS input.

RS232 Master/Slave Layout

DS6300 Master

CAB-600X

C-BOX 100

2

<

<

EN T

DS4600A Slave 1

1

*P.S.

Local Host

1

C-BOX 100

2 < EN T

PWR-120

<

DS4600A Slave 2

C-BOX 100

1

1 Main Serial Interface *

2 Auxiliary Serial Interface

P.S. (Presence Sensor) connected to External Trigger/PS input.

5

Page 8

DS6300 MASTER/SLAVE MODEL Local Lonworks Network CAB-60XX

CAB-610X BTK-6000

C-BOX 100**

Master

Encoder*** BTK-6000

Slave 1 *P.S. Local Host

CAB-63XX

PWR-120

Small Synchronized Network with 2 Readers *

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

Encoder connected to IN2/ENC input.

Local Lonworks Network Slave 2

Master

Slave 1

CAB-610X

CAB-610X

BTK-6000

C-BOX 100**

CAB-600X

*P.S. CAB-610X

Encoder*** Host CAB-610X

CAB-610X

CAB-63XX

BTK-6000

Slave 5

Slave 3

Slave 4

PWR-240

CAB-63XX

Small Synchronized Network with more than 2 Readers and Single Power Unit *

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

Encoder connected to IN2/ENC input.

6

Page 9

DS6300 MASTER/SLAVE MODEL Large Synchronized Network

** *

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

Encoder connected to ENC input. Large Synchronized Network with DX6X00 and DS6XXX Scanners

7

Page 10

DS6300 PROFIBUS MODEL

DS6300-100-011 PROFIBUS MODEL

1

Figure A 1 Laser Beam Output Window

3

5

1 3

4

1

2

2

Figure B

Figure C

1 Programming Keypad

4 Power On LED (Red)

1 Profibus 9-pin Female Connector (white)

2 TX Data LED (Green)

5 LCD Display

2 Lonworks 9-pin Female Connector

3 Phase On LED (Yellow)

3 Main/Aux. Interface 26-pin D-Sub Male Connector

Available Models: DS6300 - 10X - 0YY Decoder Model

Optical Model

10 = Master/Slave 11 = Profibus 12 = Ethernet 15 = Devicenet

0 = Standard 5 = Oscillating Mirror

Technical Features: ELECTRICAL FEATURES Supply Voltage 15 - 30 Vdc Power 15 W typical Consumption 20 W Max. (including startup current) Communication Main (isolated) Baud Rate Interfaces RS232 RS485 full-duplex with C-BOX 100 only)

Laser Control

1200 to 115200

RS485 half-duplex 20 mA C.L. (INT-30

OPTICAL FEATURES Light Receiver Avalanche photodiode Wavelength 630 to 680 nm Safety Class Class 2-EN 60825-1; Class II-CDRH

19200

Security system to turn laser off in case of motor slow down

READING FEATURES Scan Rate 600-1200 scans/s

Auxiliary RS232 Other Lonworks Profibus

Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs

8

1200 to 11500 1.25 Mb/s 12 Mb/s

(optocoupled NPN or PNP)

(optocoupled)

Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field

USER INTERFACE LCD Display Keypad LED Indicators

(see reading diagram)

2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX Data (green)