The text of a manual · part 4 of 27
AdaptaScan Software (Cat. No. 2755-ASN) User Manual: 2 - Working with Projects, pages 19 to 28
Pages 19 to 28 of 224, from AdaptaScan Software (Cat. No. 2755-ASN) User Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 19
Chapter
Working with Projects Chapter Objectives
This chapter contains the following sections: Section
Page
Running AdaptaScan Software
2–2
What is a Database File?
2–3
What is a Project?
2–3
Opening a Project
2–3
Project Window
2–4
AdaptaScan Dialogs
2–8
Saving a Project
2–12
Closing a Project
2–13
Deleting a Project
2–13
Entering Project Name, Description, and Baud Rate
2–17
Selecting Preferences
2–18
Help
2–20
2
Page 20
2–2
Working with Projects
Running AdaptaScan Software
AdaptaScan software opens like any other Windows 95 application. To start AdaptaScan software: 1. From the Windows Start menu, select Programs>AdaptaScan OLP>AdaptaScan OLP or double-click the AdaptaScan OLP icon. The AdaptaScan window opens with the database dialog:
The AdaptaScan Off-Line Programmer window is your workspace for creating projects.
Publication 2755-838
Page 21
Working with Projects
What is a Database File?
2–3
A database file provides a method of organizing projects. Each database file may contain one or more projects. From the File menu you can open existing or create new database files.
Project File
Project File
Project File
What is a Project?
Each Reader configuration is associated with a project. Each project contains one or more Reader configurations. If using DeviceNet or DH-485 communications, each project also defines one DeviceNet or DH-485 network.
Project File
Reader 1
Reader 4, . . . Reader 2
Opening a Project
Reader 3
There are two methods of creating a new project.
• From the Project menu, select New.
• Click the New Project tool on the tool bar.
The Project window opens allowing you to define a Reader configuration.
Publication 2755-838
Page 22
2–4
Working with Projects
Project Window
Creating a Reader configuration starts with the Project window. All of the basic configuration options are accessed from buttons. Selecting a button opens the corresponding dialog.
The buttons on the Project window are defined below. Select:
To: Create a new Bar Code Reader configuration (Bar Code Reader 1, Bar Code Reader 2, Bar Code Reader 3, ...) in the Project window. Delete the selected Bar Code Reader configuration from the Project window. Define label setups and symbologies for Reader operation. Define a unique name and enter a description for the Reader. Also defines a DeviceNet address for the Reader. Specify linear or raster scanning, how scanning is triggered, and accesses the focus function. Define when the Reader decodes data and what label is decoded. Also defines the inter-symbol timer and performance indicator parameters. Define the operation for package detector, discrete inputs, discrete outputs, timer and ASCII trigger commands. Define communication parameters (RS-232, RS-485/RS422) and protocols (ASCII, DH-485, DF1) for the Reader’s communication ports. Define match table, package and counter functions for decoded bar code data. Define the format and content of messages sent to the host after bar codes are decoded. Transfer the configuration stored in a Reader to the currently opened project in the AdaptaScan Software. Downloads the highlighted configurations to the device or network. View the operation of a single Reader or another Reader on the same network. Compare the Reader configuration within the project with the on–line device. Download new firmware to a selected Reader.
Publication 2755-838
Page 23
Working with Projects
2–5
Existing Configurations Any existing Reader configurations within the project are displayed in the project window:
This display shows:
• Name - Reader name as specified on the Device dialog. AdaptaScan software provides a default name of Bar Code Reader 1, Bar Code Reader 2, etc. • Device Name - read only field that displays the internally configured name of the DeviceNet device (typically the catalog number). • Network ID - the node address of the device on the DeviceNet network Note: When you go on-line with the software, any devices that are not part of the configuration but are present on the network will be added to the display. Refer to Chapter 3 for a description of the on-line functions.
Publication 2755-838
Page 24
2–6
Working with Projects
Status The project window status icons display the status of the Reader connections and configurations.
Connection Indicates device is on-line
Database Indicates Configuration is stored in the database
Device Icon Graphic representing the type of device
Connection When displayed, indicates a connection was made to the device:
• Yellow (default) indicates that the AdaptaScan software does not have the information required to determine whether the device’s configuration matches the configuration in the software database. • Green appears after a Compare operation (see page 3–4) was performed and the configuration of the on-line device matches the database configuration. • Red appears after a Compare operation (see page 3–4) was performed and the configuration of the on-line device does not match the database configuration. Database When displayed, indicates that a database configuration exists for the Reader. The color indications are the same as for the Connection icon (see descriptions above) except the database icon will remain yellow if a compare operation did not match the database. Device Icon Displays the icon associated with the device. Here are some common device icons: = AdaptaScan Reader
= SDN Scanner Card
Publication 2755-838
= PhotoEye photo-electric detector
= KFD DeviceNet Personal Computer Interface
Page 25
Working with Projects
2–7
Information Lines There are two areas on the project window that provide information about a highlighted Reader configuration.
Connections per Reader / Description Field
Version Number / Compare Status
Connections Per Reader / Description The total number of connections is displayed on the project dialog along with a device description. The description displayed is entered on the Device dialog description field. Each Reader has a minimum of 7 and a maximum of 64 connections. A connection is an AdaptaScan object that moves data both internally and between Readers. For example, when Package Detect is specified as the decode trigger, a connection moves data from the package detect input to the decoder. If the Package Detect is from another Reader, each of the Readers use the connection object. Important: You will not be allowed to download a configuration with more than 64 connections in a Reader. A warning message is displayed. However, you can still read old databases with more than 64 connections. You will need to reduce the number of items that use connections before downloading the configuration. Some items that use connections are match fields, inputs and outputs. Version Number / Compare Status The first line shows the firmware version number of the Reader. The second line shows the compare status in a text format and matches the status shown by the connection and database status icons (see previous page).
Publication 2755-838
Page 26
2–8
Working with Projects
AdaptaScan Dialogs
AdaptaScan software uses dialog boxes to request information and set operating parameters.
Drop-down List Box Radio Button
Check Box
Command Button
Spin Control
Text Box
List Box
To move around a dialog box:
• Move the mouse pointer to field and click the left mouse button. • Or press TAB to move forward through fields and SHIFT+TAB to move backward through fields. • Or press the ALT key and the underlined letter of a field name. For example, to move to the Laser Light field, press ALT+L.
Command Buttons Rectangular areas in the dialog box that look like buttons you can push. When you click a command button, it presses like a real push button.
Text Boxes Text boxes are rectangular boxes in which you type text. Sometimes these boxes contain text or a value, sometimes they’re empty. The mouse pointer changes to an I-beam when positioned over a text box. Place the pointer where you want to start typing and click the left mouse button. To replace all text, double-click in the text box and type the new text.
Publication 2755-838
Page 27
Working with Projects
2–9
List Boxes This is a box with a list of items. To select an item from a list, click on the item. A scroll bar appears beside the list box if there are more items than can fit inside the box. You can also use the arrow keys to select an item in the list. Press TAB until you get into the list box. Then, press the UP or DOWN ARROW keys to select the item you want. Some list boxes let you select multiple items. To select non-consecutive items, click the first item, press and hold down the CTRL key, then click the next item(s). To select consecutive items, click the first item, press and hold down the SHIFT key, then click the last item. To deselect a range, click the first item in the list.
Drop-down List Boxes These are text boxes with an underlined down-arrow beside them. If you click inside the text area or click on the down-arrow, the list drops down. When you select an item from the list, the list disappears.
Check Boxes Square boxes that contain an X or are blank. Check boxes are used to select or clear an option. An X in the box means the option is selected. A blank box means the option is not selected (it’s cleared). Click the box to toggle the option on or off.
Radio Buttons Circles that contain a solid dot or are blank. Radio buttons come in a group. When you click one button in a group, it clears any other option that was selected. A solid dot in the button means the option is selected. When an option is not selected, the radio button is clear (no dot).
Spin Controls Small text boxes with up-down arrows at the right. Spin controls are used to select sequential numbers. Click the up arrow to increase the number or click the down arrow to decrease the number. Or you can click in the box and enter a number.
Publication 2755-838
Page 28
2–10
Working with Projects
AdaptaScan Tools
Turn the tool bar view on or off from the View menu. The tool icons provide shortcuts to the following menu items:
Move the toolbar to any side of the window or detach the toolbar and place anywhere on your screen by clicking on and holding down the mouse key while dragging the toolbar.
Default Position
Bottom Position
Detached
Publication 2755-838
Side Window