The text of a manual · part 3 of 27
AdaptaScan Software (Cat. No. 2755-ASN) User Manual: 1 - Installation
Pages 11 to 18 of 224, from AdaptaScan Software (Cat. No. 2755-ASN) User Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 11
Chapter
1
Chapter Objectives
This chapter contains these sections: Section
System Requirements
Page
System Requirements
1–1
Installing AdaptaScan Software
1–2
Downloading Firmware
1–5
The minimum hardware and software requirements for installing and running AdaptaScan software are: Hardware
• Personal computer (486/25 MHz minimum) 8 MB of memory (RAM), VGA or higher resolution, with mouse • 3.5 inch high-density (1.44 MB) disk drive • Hard disk with 2 MB of free space • Configuration cable (Catalog No. 2755-NC48 for Series B Reader, 2755-NC43 for Series A Reader) to connect the personal computer to the Reader. Software
• AdaptaScan Software (Catalog No. 2755-ASN) • Microsoft Windows 95 or Windows NT Optional Equipment
• A printer for project printouts.
Page 12
1–2
Installation
Installing AdaptaScan Software
This section shows how to install the AdaptaScan Configuration software. To install the AdaptaScan Configuration software: 1. Insert the AdaptaScan disk #1 in the appropriate floppy disk drive. 2. In the Program Manager window, choose Run from the File menu. The Run dialog opens.
3. In the command line box, type the drive letter of the drive containing the AdaptaScan diskette followed by a colon and the word setup. For example, type a:setup Then click OK or press ENTER. The installation begins. You are prompted to continue or exit the installation.
Publication 2755-838
Page 13
Installation
1–3
4. Click Continue to proceed with the installation. You are prompted to verify/provide registration information.
5. Enter the registration data. Verify the software serial and catalog number with the label on the software diskette. Click Continue to proceed with the installation. You are prompted for the location of files to be installed.
We recommend that you use the default installation path. To change the installation drive or file name, click the Set Location button. 6. Click the Install button to proceed with the installation You are shown the progress of the installation. Insert disk #2 when requested. A message indicates when the installation is complete.
Publication 2755-838
Page 14
1–4
Installation
AdaptaScan Installation Summary The default AdaptaScan installation: • Copies files to disk under the target drive and directory (C:\AS_OLP) or the location specified during installation. • Adds ”AdaptaScan Off–Line Programmer” to registry • Adds AdaptaScan OLP to the Windows Start menu • Creates an AdaptaScan group containing icons for AdaptaScan software and the Windows help file.
Registering AdaptaScan Software Please take time to complete and send in the registration card you received with AdaptaScan software. Registering entitles you to: • automatic notification of upgrades and revisions to AdaptaScan software • technical assistance
AdaptaScan Installation Files File AB.SYS ADAPTASC.HLP
AdaptaScan help system.
ADAPTASC.CNT
AdaptaScan help contents.
ADPTSCN1,2,3.EDS
Contains product information for DeviceNet Manager.
APPGUIDE.DBF APPGUIDE.ID1
Publication 2755-838
Function User information provided during installation.
Database containing example projects from the AdaptaScan Application Guide. Index for database.
OLP.EXE
AdaptaScan software executable.
SNEXxxxx.BIN
Contains firmware code for Reader.
SNEXxxxx.INI
Reader firmware update file.
Page 15
Installation
Downloading Firmware
1–5
Each Reader is shipped with manufacturing firmware installed. You must download the release firmware prior to programming the Reader. All the devices on the same network must have the same firmware installed. Note: Download firmware with a computer connected directly to the Reader configuration port.
!
ATTENTION: Do not download firmware while the scanner is on a DeviceNet master/slave network or you will cause unrecoverable damage to the scanner.
Connect Configuration Cable The configuration cable connects the configured communications port (see Preferences, page 2–18) of the computer running AdaptaScan software to the Configuration Port Connector of the Reader. Downloads may also be done through the the Reader serial communication ports when scanner protocol is selected (see page 8–6).
Configuration Cable (Catalog No. 2755-NC48 Series B Reader 2755-NC43 Series A Reader)
9 to 25 Pin Adapter may be required
9 Pin Male D Connector 4 Pin Female Circular Connector
Personal Computer
Configuration Port Connector
Connect power, refer to Reader User Manual (Publication 2755-837)
Make Power Connections After connecting the configuration cable, you can connect power to the wiring base. The Reader User Manual (Publication 2755-837) contains wiring diagrams and instructions.
Publication 2755-838
Page 16
1–6
Installation
Verify DeviceNet Address The Reader is shipped with a default DeviceNet address of 63. Verify that the DeviceNet address is still set at 63. 1. From the Windows Start menu, select Programs>AdaptaScan OLP>AdaptaScan OLP. The database dialog opens.
2. Click the New button. The AdaptaScan project window opens.
Publication 2755-838
Page 17
Installation
1–7
3. From the Communications menu, select Go-Online. The Reader will be detected (if properly connected) and displayed in the project window. Note: The Query dialog may be displayed when you go on-line (depending on your preference settings). Refer to page 2–19.
4. If the address displayed is not 63, change the Reader address by clicking the Device button. The Device dialog opens showing the current address. If the Device is online but not in the project database, the following dialog is displayed:
If the Device is online and in the current project database, the following dialog is displayed:
5. Change the address and click Apply.
Publication 2755-838
Page 18
1–8
Installation
Download the Firmware to the Reader 1. Check that Reader is properly connected to your computer (using configuration cable) and has power applied (refer to page 1–5). 2. Select Preferences from the View menu.
SNEXaaaa.ini
3. Make sure the communications channel is set to Configuration Port. 4. From the Communications menu, select Go-Online. The Reader will be detected (if properly connected) and displayed in the project window. Note: The Query dialog may be displayed when you go on-line (depending on your preference settings). Refer to page 2–19. 5. From the Project window (see page 1–6), highlight the Reader name and then click the Firmware button. The Open dialog is displayed allowing you to enter or browse to the firmware file you want to download.
Select .ini Firmware File aaaa = Version Number
SNEXaaaa.ini
6. Select the firmware file you want to download and click OK. The following messages appear as the firmware is downloaded. Downloading will take several minutes. During this time the Module LED will flash red. Resetting. Please Wait . . . Sending. Please Wait . . . 7. The messages disappear when the download is complete. You are ready to create a Reader configuration.
Publication 2755-838