Working with Projects
2–11
Tool Summary The following provides a brief summary of the AdpataScan tools.
Tool or Select from menu:
Icon
Description
For additional information, see page:
Create New Database
File >New
Creates a database file that will contain project configuration files.
2–3
Open Existing Database
File >Open
Opens window allowing you to select an existing database file (.dbf) containing project configuration files.
2–3
Open Selected Project
Project >Open
Opens the project currently selected in the AdaptaScan database file window.
2–3
Create New Project
Project >New
Creates a new project within the currently open database file (.dbf).
2–3
Go On-Line
On-Line Tools >Go On-Line
Connects the programming computer to the network.
3–2
Go Off-Line
On-Line Tools >Go Off-Line
Disconnects the programming computer from the network.
3–2
Upload Selected Configuration into Project
On-Line Tools >Upload
Uploads the configuration stored in the selected device to the current project.
12–3
Download Selected Configurations to Network
On-Line Tools >Download
Downloads the selected Reader configuration(s) to the Readers on the network.
12–5
Open Monitor Window
On-Line Tools >Monitor
Opens on-line monitor window.
3–5
Compare Project Configuration with On-Line Device
On-Line Tools >Compare
Compares the configuration database of the currently selected Reader to the actual configuration stored within the Reader.
3–4
Cut Selection to Clipboard
Edit >Cut
Removes the currently selected item from the dialog or window and places the item on the clipboard.
2–14
Copy Selection to Clipboard
Edit >Copy
Copies the currently selected item from the dialog or window and places the copy on the clipboard.
2–14
Paste Clipboard Contents
Edit >Paste
Pastes the last item placed on the clipboard to the currently selected location.
2–14
File >Print
Opens the print dialog that allows you to print out an application report.
13–2
About AdaptaScan Software
Help >About Off-Line Programmer
Opens a dialog showing the software revision and serial numbers along with other software information.
Help >Contents
When selected, displays a pointer. this pointer may be moved to an area on a dialog or menu and clicked for help about the item.
On-Line Context Help
2–20
Publication 2755-838
Page 30
2–12
Working with Projects
Saving a Project
Project information is saved as you configure each dialog box. AdaptaScan dialog boxes have one or more of the following buttons.
Save Button Saves the dialog information. If you close a dialog without saving, you are prompted: Changes have been made. Do you want to save these changes before closing?
If you select No, all changes to the dialog (and associated dialogs accessed from the dialog) are deleted. Selecting Yes saves changes.
Apply Button Sends the dialog data to the specified Reader. Use Apply when making changes to the Scanner or Device dialogs while online.
OK Button Accepts the data within the dialog box. The dialog information is saved on the previous dialog (after selecting OK).
Publication 2755-838
Page 31
Working with Projects
Closing a Project
2–13
This section shows how to close a project. When closing a project, use one of the following methods. You are prompted to save information if changes were made but not saved.
• With the project you want to close as the active window (or icon), select Close from the Project menu.
• Or select Close from the control menu on the project window. Control Menu Box
The Project window closes but the AdaptaScan Off-Line Programmer window remains open.
Deleting a Project
With the project you want to delete as the active window (or icon), select Delete from the Project menu.
You are prompted: Are you sure you want to delete (Project Name). After deletion, there is no way to recover it.
Select Yes to delete the project. When a project is deleted, all project data is deleted from the program database and cannot be restored. Select No to cancel the delete function.
Publication 2755-838
Page 32
2–14
Working with Projects
Using Cut, Copy and Paste
The following items may be cut, copied and pasted within and between database files:
• • • • • • projects Reader configurations match functions message fields labels symbols (can’t be copied)
The cut, copy, and paste icons and menu selections will only be available where they can be used. Otherwise the icons will appear grayed out. Important: Cutting or copying and then pasting a Reader configuration is different from importing/exporting Reader configurations. When an individual Reader configuration is pasted into a project, only the original Reader’s configuration dialog boxes are copied and recreated in the new project. Connections to and from the original configuration are not recreated using Paste. Paste is useful when you need to make a configuration similar to an existing configuration in the currently open project or another project. When you need to make an exact copy of a configuration, copy and paste the entire project in the AdaptaScan database dialog or use the import/export functions (see next page).
Publication 2755-838
Page 33
Working with Projects
Importing/Exporting Reader Configurations
2–15
Using the import/export functions you can transfer exact copies of Reader configurations between projects. The imported/exported configurations maintain the internal and external connections (see page 2–7 for a description of connections). To import a Reader configuration into a project: 1. Open the project you want to import the configuration file into. 2. From the File menu, select Import. The Import Configuration dialog is displayed.
3. Enter the path>filename of the Reader configuration you want to import (.cfg file). 4. Click Open to import the Reader configuration into the project.
Publication 2755-838
Page 34
2–16
Working with Projects
To export a Reader configuration from a project: 1. Open the project that contains the file being exported. 2. Highlight the Reader configuration you want to export. 3. From the File menu, select Export. The Export Configuration dialog is displayed.
4. Select the directory in which you want to place the Reader configuration. 5. Click Save to export the Reader configuration. The file will appear in the directory with a .cfg extension.
Publication 2755-838
Page 35
Working with Projects
Entering a Project Name, Description, and Baud Rate
2–17
AdaptaScan software creates projects with a default name (Project 1, Project 2, ...) and a default DeviceNet baud rate of 125K. To rename a project, enter a project description or change the baud rate, open the project you want to edit. With the project as the currently active window, select Edit from the Project menu.
The Project dialog opens.
Enter a new project name and description. Select a baud rate that is compatible with the DeviceNet network on which the Readers are communicating.
Publication 2755-838
Page 36
2–18
Working with Projects
Preferences
The Preferences dialog allows you to specify options related to computer communications. With the project as the currently active window, select Preferences from the View menu.
The Preferences dialog opens.
Select:
To:
DeviceNet
Select DeviceNet to communicate with a Reader through a DeviceNet network. A DeviceNet communications card and driver software must be installed on your computer.
Configuration Port
Specify a direct connection to a Reader’s configuration port. This is the default setting. Specify the communications port on your computer used to configure the Reader. The options are COM1 through COM9. Enter the amount of time your computer will wait for a response before a timeout occurs. Enter a value between 1 and 60, the default is 10.
Port Timeout (Seconds)
Publication 2755-838
NAK Retries
Enter the number of times your computer will accept a NAK (negative acknowledgement) before a communications fault occurs. Enter a value from 0-20, the default is 2.
Timeout Retries
Enter the number of times your computer will attempt to establish communications after a timeout. Enter a value from 0-20, the default is 2.
Page 37
Working with Projects
2–19
Network Query Preferences The Query dialog specifies the network addresses that are checked when the AdaptaScan software checks the network. By specifying just the addresses that need to be read, you can speed up network operations.
The Query dialog is displayed when you:
• select Query from the View menu • select Go On-Line from the Communications menu • select Refresh from the Communications menu Specify the network address you want to check: Select
To:
All
Check all addresses (0 to 63).
Displayed
Check only the connections displayed in the project window (see page 2–4). Check only the connections displayed and highlighted in the project window (see page 2–4). Check only the addresses listed.
Selected Specified
To disable the Query dialog from displaying when you use on-line tools, uncheck the checkbox on the bottom of the dialog. You can still access the dialog from the View menu after unchecking the box.
Publication 2755-838
Page 38
2–20
Working with Projects
Help
Both general and context sensitive Help is available. Access general Help topics by choosing Contents from the Help menu.
Help feature
How to use it
Contents Tab
Choose to display the help content books.
Index Tab
Choose to see an alphabetical list of topics.
Find Tab
Choose to search for topics by keywords.
Access context sensitive help by choosing the Help button available on all dialogs. Or click the Help tool want help for.
Publication 2755-838 and then the item you