Page 92

6–10

Selecting Symbologies for a Bar Code Label

Open the Symbologies dialog by selecting the Symbologies button on the Bar Code Label Dialog. This dialog defines characteristics specific to each symbology.

Symbology List the available symbologies. A check mark in front of the symbology indicates that the symbology is used in the label definition.

☞ Or double-click on a symbology to open the corresponding dialog.

Publication 2755-838

Select the Edit button to open a dialog for a highlighted symbology.

Page 93

6–11

Code 39 and Codabar ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the Code 39 or Codabar dialog by highlighting the symbology in the Symbologies dialog and then selecting the Edit button.

Check Character Verify

Verify & Strip

None

Verify the check character for each symbol that is read. A symbol is invalid if the calculated code does not match the decoded check character. Code 39 checksum is the modulus 43 sum of all character values. Codabar checksum is the modulus 16 sum of all character values. Verify the check character on each symbol and then remove the check character from the data. The symbol is invalid if the calculated code does not match the decoded check character. Check characters are not verified.

Discrete 2 of 5 ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the Discrete 2 of 5 dialog by highlighting Discrete 2 of 5 in the Symbologies dialog and then selecting the Edit button.

Guard Bars Verifies the presence of guard bars. When selected, the guard bars must be present to decode a symbol. When not selected, the symbol is decoded with or without guard bars.

Publication 2755-838

Page 94

6–12

Interleaved 2 of 5 ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the Interleaved 2 of 5 dialog by highlighting Interleaved 2 of 5 in the Symbologies dialog and then selecting the Edit button.

Check Character Select:

To:

None

Handle all decoded characters as data.

Verify

Verify the check character on each symbol that is read. The symbol is invalid if the calculated code (modulus 43 sum of all character values) does not match the decoded check character.

Verify & Strip

Verify the check character on each symbol and then remove the check character from the data. The symbol is invalid if the calculated code does not match the decoded check character.

Guard Bars Verifies the presence of guard bars. When selected, the guard bars must be present to decode a symbol. When not selected, the symbol is decoded with or without guard bars. Enable 2 Character Codes Allows reading of Interleaved 2 of 5 symbols consisting of only 2 characters. The Reader will ignore 2 character symbols unless this box is selected. Note: Do not enable 2 character codes unless you are reading 2 character codes. Otherwise, a partial scan of symbols could result in a valid short read.

Publication 2755-838

Page 95

6–13

UPC-A, UPC-E, EAN-8, EAN-13 ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the UPC and EAN dialogs by highlighting the symbology in the Symbologies dialog and then selecting the Edit button.

Supplements Select:

To:

2

Enable decoding of 2 character supplements. Both the primary code and supplement are required for a valid read. Enable decoding of 5 character supplements. Both the primary code and supplement are required for a valid read. Enable decoding of both 2 and 5 character supplements. Both the primary code and supplement are required for a valid read. Enable the Reader to decode labels with or without supplements. Just the primary code is required for a valid read.

5 2 and 5 Auto

Expand (UPC-E Codes Only) When selected, bar code data is transmitted in a 12 digit (expanded) format. If Expand is not selected, data is sent in a 6 digit (compressed) format.

Publication 2755-838

Page 96

6–14

Matrix 2 of 5 When editing the Matrix 2 of 5 symbology, the following options are available:

Check Character Select:

To:

None

Handle all decoded characters as data.

Verify

Verify the check character on each symbol that is read. The symbol is invalid if the calculated checksum (see below) does not match the decoded check character.

Verify & Strip

Verify the check character on each symbol and then remove the check character from the data. The symbol is invalid if the calculated code does not match the decoded check character.

Guard Bars Verifies the presence of guard bars. When selected, the guard bars must be present to decode a symbol. When not selected, the symbol is decoded with or without guard bars. Matrix 2 of 5 Check Character The AdaptaScan performs a modulus 10 check of a Matrix 2 of 5 code as follows: 1. Start and Stop codes are not included in the checksum. 2. Sum of even position digits is multiplied (weighted) by 3. 3. Sum of odd position digits is multiplied (weighted) by 1. 4. Odd and even weighted results are added together. 5. Divide the sum of the odd and even weighted results by 10. 6. Subtract the remainder of the division from 10 to obtain the checksum.

For example, the following code is decoded, the most significant digit (digit #1) is to the left. The least significant digit is to the right and is an even position digit. Code = 8 6 1 3 2 5 1 8 Sum of 3 (sum even digits) + (sum odd digits) = 3 (6 + 3 + 5 + 8) + (8 + 1 + 2 + 1) = 78 Sum/10 = 78/10 = 7 with Remainder = 8 Checksum = 10 - Remainder = 10 - 8 = 2

Publication 2755-838

Page 97

6–15

Pharma Code ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the Pharma Code dialog by highlighting Pharma Code in the Symbologies dialog and then selecting the Edit button.

Min # of Bars Specifies the minimum number of bars required in a valid Pharma Code symbol. The Reader only decodes symbols with an equal or greater number of bars than the minimum bar setting. Valid values are 3 to 12. The default is 5. Decode Direction The Reader uses the decode direction to determine the least significant bar within a symbol. Select:

To:

Forward

Decode symbols in a left to right direction.

Reverse

Decode symbols in a right to left direction.

The decode direction determines the value of the decoded symbol: Least Significant Bar

Decode Direction Value = 94

Most Significant Bar

Least Significant Bar

Most Significant Bar

Decode Direction Value = 125

Publication 2755-838

Page 98

6–16

Space Tolerance The maximum allowed tolerance (percent difference in width) between the narrowest and widest space elements. Enter:

To:

Tolerance

Specify the percent difference (in width) between the narrowest and widest space elements. Enter a value between 5 and 40. The default of 15 is recommended for most applications.

Space tolerance is calculated as follows; Widest Space – Narrowest Space x 100 = % Space Tolerance

Widest Space + Narrowest Space 3

Min Wide to Narrow Bar Ratio Specifies the minimum ratio of the widest bar to the narrowest bar within a symbol. Select: No Check, 2, or 3. Bar Tolerance Note: The maximum number of bars allowed in a symbol is 12. The maximum tolerance (percent difference in width) between two wide bars of a symbol or between two narrow bars of a symbol. Enter a value between 5 and 40. The default of 15 (15%) is recommended for most applications. Bar tolerances are calculated as follows: Widest Wide Bar – Narrowest Wide Bar x 100 = % Wide Bar Tolerance

Widest Wide Bar + Narrowest Wide Bar 3

Widest Narrow Bar – Narrowest Narrow Bar Widest Narrow Bar + Narrowest Narrow Bar 3

Publication 2755-838 x 100 = % Narrow Bar Tolerance

Page 99

6–17

USPS 2 of 5 ☞ Or double-click on a symbology in the Symbologies box to open the dialog.

Open the USPS 2 of 5 dialog by highlighting USPS 2 of 5 in the Symbologies dialog and then selecting the Edit button.

Decode Direction The Reader uses the decode direction to determine the least significant bar within a symbol. Select:

To:

Forward

Decode symbols in a left to right direction.

Reverse

Decode symbols in a right to left direction.

The decode direction determines the value of the decoded symbol: Least Significant Bar

Most Significant Bar

Most Significant Bar

Decode Direction = Reverse Value = 53041

Decode Direction = Forward Value = 15084

Space Tolerance The maximum allowed tolerance (percent difference in width) between the narrowest and widest space elements. Enter a value between 5 and 40. The default of 20 (20%) is recommended for most applications. Space tolerance is calculated as follows; Widest Space – Narrowest Space

Least Significant Bar x 100 = % Space Tolerance

Widest Space + Narrowest Space 3

Publication 2755-838