Page 100

Chapter

Chapter Objectives

This chapter configures the operation of the Reader’s decoder. Section

Helpful Hints

7

Page

Helpful Hints

7–1

Decoding Functions

7–1

Valid Symbologies

7–2

When Decoding Occurs

7–3

Capture Count

7–5

Setting Decode Parameters

7–6

Configuring the Performance Indicator

7–8

Viewing Readers with the Same Trigger Source

7–10

When configuring the Reader’s decode functions:

• Enable only the bar code symbologies the Reader will scan to increase decode speed and reduce misreads. • During initial setup, use the Self-Triggered decode option and specify an Inter-Symbol No-Read Count. The Reader will continuously attempt to decode data. • To prevent misreads, trigger decoding only when a bar code label is within the scan area of the Reader.

Decoding Functions

The Decoder dialogs define: • When the Reader decodes bar code symbols from the scanner. • What bar code symbologies are decoded. • Minimum performance level before an alarm occurs.

Page 101

7–2

Valid Symbologies

The Reader can be configured to decode the following symbologies:

Interleaved 2 of 5

Code 39

Discrete 2 of 5

UPC-A

UPC-E

USPS 2 of 5

EAN-8

EAN-13

Code 128

Pharma Code

Codabar

Code 93

Each of the symbologies has properties you can set up such as guard bars, check characters and supplements.

Guard Bar

Guard Bar

Supplemental Digits

Publication 2755-838

Page 102

7–3

When Decoding Occurs

The Decoder dialog settings determine when the Reader starts and stops decoding. The trigger source may be from or on the Reader you are configuring or another Reader on the same network (when using DeviceNet peer-to-peer communications). You can use the same package trigger for multiple Readers on a DeviceNet peer-to-peer network or you can “chain triggers” where one Reader is a trigger source for another Reader. Once triggered, the Reader attempts to decode symbols until a trigger off is received. Trigger inputs include: Self-Triggered, Package Detect, Discrete Input, Timer, ASCII Command, Input Timer, or DeviceNet Inputs. You can also select bracketed indirect trigger sources defined for other functions such as [Match Table], [Package], [Message]. Note: [Match Table], [Package] or [Message] do not appear as options unless a trigger has been defined for the match table, package or message functions. Self-Triggered Source The Reader continuously attempts to decode data. Package Detect Trigger Source The Reader decodes data only after receiving a trigger from the package detect sensor attached to the Reader. Photo-Electric Package Detector

Publication 2755-838

Page 103

7–4

Discrete Input Trigger Source The Reader decodes data only after receiving a trigger from a discrete input (located in the wiring base).

Reader

I/O Modules Wiring Base

Timer Trigger Source The Reader decodes data only when the internal timer is On. The timer can be configured On or Off for independent periods of time.

Internal Timer

ASCII Command Trigger Source Data is only decoded after an ASCII Trigger On command is received. The Reader decodes data until a Trigger Off command is received, a valid package is decoded or the timer times out.

ASCII Host Command

Publication 2755-838

Page 104

7–5

Input Timer Timer which is triggered by another source. Typically used to coordinate multiple Readers scanning the same package. DeviceNet Input Up to 7 discrete DeviceNet inputs trigger decoding. Refer to Configuring DeviceNet Inputs on page 9–15. [Package] The same trigger configured for package is also used to trigger decoding. See page 11–13. [Message] The same trigger configured for messages is also used to trigger decoding. See page 10–5. [Match Table] The same trigger configured for match table is also used to trigger decoding. See page 11–8. [Decoder] The same trigger configured for decoding on another Reader is also used to trigger decoding on the current Reader.

Capture Count

The capture count specifies the number of consecutive identical valid decodes before a valid read occurs. Scan 1 ABC

If Capture Count is 3 or less, Scan is Valid Scan 2 ABC

If Capture Count is 4 or more Scan is not Valid

Scan 3 ABC

Use higher capture counts to reduce misreads. Symbologies that are not self-checking (do not use start and stop characters or check characters) are more susceptible to misreads. Setting the capture count too high may result in excessive no-reads, particularly when the number of scans crossing the label during a trigger period is low (5-10). Set the capture count to a value no greater than half the number of scans crossing the label during a single trigger period.

Publication 2755-838

Page 105

7–6

Setting Decode Parameters

The Decoder dialog configures decoding functions and is opened by selecting the Decoder button on the main Project window.

Opens Used By Dialo Opens More Dialog

Capture Count Specifies the number of identical valid scans that must be decoded for a valid read. Enter a value from 1 to 8. Use the default value of 2 for most applications. Bar Code Label Specifies the label setup the Reader is to decode. If none are defined, you can select the Label button to open the Labels dialog. Triggered By Specifies the trigger source to initiate decoding. The trigger is defined by the Reader name and type of trigger input. Self-Triggered When selected, decoding occurs continuously. Use the Inter-Symbol No-Read Count (see page 7–9) to prevent multiple decodes of the same symbol. Note: When using Self-Triggered, increase the capture count to greater than 2 (we recommend a value of 5 or 6).

Publication 2755-838

Page 106

7–7

Device Selects the device that is the source of the trigger. The trigger may be from the current Reader or any other Reader on the same network. Input Select:

To Trigger Decoding:

Package Detect

Using the package detect input.

Timer

Using the Reader’s internal timer.

ASCII Command Discrete I/O

Using an ASCII command sent from a host.

Input Timer

Using an input timer.

DeviceNet Input [Package]

Using one of the 7 DeviceNet inputs. Using the trigger defined for packages.

[Message]

Using the trigger defined for messages.

[Match Table]

Using the trigger defined for the match table.

[Decoder]

Using the same trigger assigned to the Decoder of another Reader.

Using a Reader input module.

Publication 2755-838

Page 107

7–8

Configuring the Performance Indicator

The Decoder-More dialog configures the operation of the performance indicator and inter-symbol timer. Open this dialog by selecting the More button on the Decoder dialog.

Performance Indicator Output Configures the output indicator to assert when the margin or number of decoded scans drops below a setpoint. Select:

To:

Low Limit

Specify the setpoint at which a discrete output signals low performance. Enter a value between 0 – 99%, which represents either margin or a count of the valid reads during a trigger period. Enable/Disable the low performance output indicator. Low performance output is disabled when this button is selected. Performance indicator triggered when the number of decodes per trigger period drops below the Low Limit setting. The number of decodes per trigger is updated at the end of the trigger.

Disable Count

Margin

Performance indicator is triggered when the decode margin drops below the Low Limit setting. See page 3–8 for a description of margin.

Device

Specify the Reader to receive the output indication when performance falls below the low limit. Specify the output module to energize on the Reader when performance falls below the low limit.

Output

Publication 2755-838

Page 108

7–9

Inter-Symbol No-Read Count Specifies the minimum number of no-reads that must occur between decoded symbols before the next symbol can be decoded. This prevents multiple decodes of the same symbol while allowing identical symbols to be decoded as long as a definite space (no–read) occurs between them: Inter-Symbol No-Read Count = 3 Direction of Travel 1st Symbol Scanned

2nd Symbol Scanned

Last Symbol Scanned

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7 Publication 2755-838

Page 109

7–10

Viewing Readers with the Same Trigger Source

The Used By dialog lists other Readers that use the same trigger source. Use this dialog when making changes to a configuration and you want to view or change other configurations assigned to the same trigger source.

Currently Used By Displays the Reader configurations that use the decoder trigger as a trigger source. Highlight the configuration you want to access and click the Goto button.

Publication 2755-838