The text of a manual · part 11 of 27
AdaptaScan Software (Cat. No. 2755-ASN) User Manual: 6 - Defining Labels, pages 83 to 91
Pages 83 to 91 of 224, from AdaptaScan Software (Cat. No. 2755-ASN) User Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 83
Chapter
6
Defining Labels Chapter Objectives
This chapter describes the dialog boxes that define a label setup. A label setup defines the label contents the Reader is expected to read. Section
Helpful Hints
Page
Helpful Hints
6–1
What is a Label?
6–2
What is a Label Setup?
6–3
Managing Bar Code Labels
6–4
Defining a Bar Code Label
6–5
Used By Dialog
6–7
Defining Symbols for a Bar Code Label
6–8
Selecting Symbologies for a Bar Code Label
6–10
When defining a label setup:
• Enable only the symbologies the Reader is expected to scan to increase the Reader’s response rate. • Define as many parameters as you can for each label and symbology to prevent the possibility of a misread. • You can define label setups at any time (before or after other Reader settings). However, label setups are assigned to a Reader using the Decoder dialogs. It may be easier to create the label setups prior to defining the operation of the decoder. • For initial setup use the default settings when possible. When a configuration is working, change decoder settings one at a time while verifying the operation of the Reader (see Chapter 13).
Page 84
6–2
What is a Label?
A label usually contains human readable text and one or more bar code symbols that appear within the Reader scan area on a package. Each bar code symbol may have different characteristics such as symbology, prefixes, lengths, or check characters. The bar code symbols must be oriented in the same direction if read by a single scanner. Below is an example of a typical label. PART NO. (P)
QUANTITY (Q)
SUPPLIER (V)
SERIAL (S)
27842 9106
By defining the expected content of a label, you can reduce the possibility of a misread and increase the read rate. AdaptaScan software can store and exchange label setups between Readers, allowing you to create a library of label configurations.
Publication 2755-838
Page 85
6–3
What is a Label Setup?
A label setup defines what labels the Reader is to scan. A typical label is defined below. Symbols Per Scan Two Code 39 bar code symbols are scanned followed by a single UPC-A symbol. Symbols per Scan is set to Any.
Quiet Zone Ratio Set to default of 7.
Model Number
Manufacturing No.
Symbology Two Code 39 bar code symbols are scanned followed by a single UPC-A symbol. Code 39 labels do not use a check character and the UPC-A label does not have any supplements. Negative Image All symbols are positive images (black bars) so Negative Image is not selected. Specific Lengths UPC-A symbols are always 12 characters so a length cannot be specified. The Code 39 symbols are set to a specific length of 7. Indentifier Identifier is not required.
Publication 2755-838
Page 86
6–4
Managing Bar Code Labels
The Bar Code Labels dialog defines what labels the Reader is to decode. Open this dialog by selecting either: • Labels button on the main Project dialog. • Label button on the Decoder dialog.
Bar Code Labels Displays a list of defined bar code labels. Select:
To:
New
Open the Bar Code Label dialog to create a new label definition. Open the Bar Code Label dialog for the highlighted label definition. Cut the highlighted label definition to the clipboard.
Edit Cut Paste
Publication 2755-838
Move the label definition from the clipboard to the Bar Code Labels listing. Select Paste multiple times to make copies of the label definition.
Page 87
6–5
Defining a Bar Code Label
The Bar Code Label dialog specifies the symbols allowed on a bar code label and other label parameters. Open this dialog by selecting the New or Edit button on the Bar Code Label dialog.
Opens the Symbologies Dialog
Label Name Specifies a unique name (up to 250 alphanumeric characters including spaces) for the label definition. The name appears in the Decoder dialog allowing you to assign the label to a Reader. Symbols Per Scan Specifies the number of bar code symbols the Reader must read in a single scan (single left - right movement of the scan beam). Select:
To:
1
Read a single bar code symbol in each scan.
2-6
Read up to 6 bar code symbols within a single scan.
Any
Read labels where the number (from 1 to 6) or location of bar code symbols varies or is unknown. The symbols within a label must be unique. Identical symbols on separate scans are seen as duplicates; the second symbol is ignored.
Publication 2755-838
Page 88
6–6
Quiet Zone Ratio Specifies the ratio of the clear space before the first bar and after the last bar to the narrow element width. Enter a value from 1 to 10, 7 is the default. Symbology standards require a quiet zone ratio of 10. However, the default of 7 allows for compensation of noncompliant symbols. The Reader uses the quiet zone to determine if adequate clear space precedes and follows the symbol. Symbols without an adequate quiet zone are ignored. Clear Space
Width Clear Space Width 1st Bar
Clear Space
Quiet Zone Ratio = 10
Negative Image When selected, only negative images of bar code symbols are decoded. A negative image has white bars on a dark background.
Normal Code
Negative Image
Symbols Select:
To:
New
Open the Bar Code Label Symbol dialog to define a symbol.
Edit
Open the Bar Code Label Symbol dialog for the highlighted symbol definition. Cut the highlighted symbol definition to the clipboard.
Cut Paste
Publication 2755-838
Move the symbol definition from the clipboard to the Bar Code Label Symbol list. Select Paste multiple times to make copies of the symbol definition.
Page 89
6–7
Viewing Readers with the Same Bar Code Label Setup
The Used By dialog lists Readers using the same label setup. Use this dialog when making changes to a label setup and when you want to view or access other Reader configurations using the same setup.
Currently Used By
☞ Or double-click on the highlighted label setup.
Displays Reader configurations that use the same label setup. Highlight the label setup you want to access and click the Goto button. A dialog opens for the highlighted Reader.
Publication 2755-838
Page 90
6–8
Defining Symbols for a Bar Code Label ☞ Or double-click on a symbol name in the Symbols box to open the dialog.
The Bar Code Label Symbol dialog defines the symbols expected on a bar code label. Open the Bar Code Label Symbol dialog by: • Selecting the New button on the Bar Code Label dialog (creates a new symbol definition). • Selecting the Edit button on the Bar Code Label dialog (opens dialog for highlighted symbol definition).
Name Specifies a unique name for the symbol definition. The name appears in the Symbols list of the Bar Code Label dialog, allowing you to assign the symbol definition to the label setup. Symbology Specifies the symbology associated with the symbol name. The options are: Codabar, Code 128, Code 39, Code 93, Discrete 2 of 5, EAN-13, EAN-8, Interleaved 2 of 5, Matrix 2 of 5, Pharma Code, UPC-A, UPC-E, and USPS 2 of 5. Identifier Optional data field in which you enter characters that identify the symbol from other symbols on the same label. The identifier is used when a symbol has a unique prefix (P,Q,V,S, etc). For an example see page 6–2. Note: This field supports metacharacters. Refer to Appendix C for a description of the available metacharacters. Make sure that the characters you enter are not misinterpreted as a metacharacter string or unintended operation may result.
Publication 2755-838
Page 91
6–9
Include Identifier When selected, the identifier is included as part of the symbol data. Lengths Optional data field that specifies the minimum and maximum number of characters in the symbol. Enter up to 3 specific lengths for each symbol definition. Symbols that do not have the specified number of characters are ignored. For:
Guidelines are:
Code 39
The code length includes the check character but not the start and stop characters. Code length includes the check character and the start and stop characters. The code length does not include the check characters or start and stop characters. Shift characters within the symbol are not included in the length. The Reader ignores Code 128 FNC2, FNC3, and FNC4 characters regardless of the CODE 128 FNC1 setting. FNC2, FNC3, FNC4 are also ignored by the specific length check. The code length does not include the check characters or start and stop characters. Shift characters within the symbol are not included in the length.
Codabar Code 128
Code 93
Discrete 2 of 5 I 2 of 5 Matrix 2 of 5 PharmaCode
USPS 2 of 5
The code length includes the check character but not the start and stop characters. The code length includes the check character but not the start and stop characters. The code length includes the check character but not the start and stop characters. The length defines the number of characters in the decoded symbol. The maximum character length of a 12 bar Pharmacode symbol is 5. Does not have start, stop or check characters. The length is the number of data characters in the symbol.
Publication 2755-838