Page 32

32

Bar Code Readers Application Guide

Chapter 18 – Using DH485 in Slave Mode with an SLC 5/03 or SLC Controller

This application describes how to set up the AdaptaScan bar code reader from an SLC 5/03 or SLC 5/04 controller using DH485 protocol in slave mode. DH485 Master is used for bar code data traveling at medium or slow speeds. Data is sent to the SLC 5/03 or SLC 5/04 controller whether it was requested or not by the SLC 5/03 or SLC 5/04 controller. DH485 Slave is used for bar code data traveling at high speeds. The SLC 5/03 or SLC 5/04 controller initiates the request for bar code data. Refer to chapter 3 for a listing of additional host commands and response codes.

Hardware Requirements

The hardware items required for this application are: • 2755-SN3, -SN5, or -SN8 AdaptaScan Bar Code Reader • 2755-PW46 or -PW47 Power Supply • 2755-NC43 or -NC48 Configuration Cable • 2755-NB40 or -NB41 Wiring Base (Ser. A/Rev. B or higher) • 1747-L532, -L541, -L542, or -L543 SLC Processor • 1746-A4, -A7, -10, or -A13 Chassis • 1746-P3 Power Supply • 1747-CP3 RS-232 Programming Cable • 1747-AIC Isolated Link Coupler or 1761-NET-AIC Advanced Interface Converter • 1747-PIC RS-232/DH-485 Converter • Computer running Windows 3.1 (or later) or Windows • 9-to-25 Pin Adapter (for computers with a 25-pin COM port)

Software Requirements

The software requirements for this application are: • 2755-ASN AdaptaScan Offline Programming Software • 9323-PA2E Advanced Programming Software. (The original ICOM SLC software is not compatible with this AdaptaScan network.)

Related Publications

Related publications include:

Publication 2755-6.8.1

Publication

Description

2755-837

AdaptaScan Bar Code Readers User Manual

2755-838

AdaptaScan Software User Manual

1747-6.2

SLC Modular Hardware Style Installation and Operation Manual

9399-APSUM-11.15.95

Advanced Programming Software User Manual

Page 33

Bar Code Readers Application Guide

Connecting a Power Supply to the Reader

33

The following illustration shows how to connect a 2755-PW46 or -PW47 power supply to a single bar code reader. Use a shielded cable (Belden 9316 recommended) to make the connections. Connect the shield to the ground screw on the reader’s wiring base. 2755-PW46 Power Supply

Reader 24V+

V-

Ground Screw on Wiring Base

Connecting to the DH-485 Network

The wiring base of the AdaptaScan Reader has an RS-485/RS-422 terminal block for point-to-point or network connections. This section shows three connection options: • Connecting readers to SLC 5/03 • Connecting readers to SLC 5/04 using two 1747-AIC Modules • Connecting readers to SLC 5/04 using one 1747-AIC Module Note: You can use the 1761-NET-AIC Advanced Interface Converter in place of the 1747-AIC Module. Important:

The DH485 network cable requires proper shielding, grounding and termination. Refer to Data Highway/Data Highway Highway DH485 Cable Installation Manual (Publication 1770-6.2.2).

Important:

When setting up a DH-485 network using an AdaptaScan, make sure that the nodes on the network are in sequential order. The SLC 5/03 or 5/04 should be Node 1, and AdaptaScan should be Node 2, and each node after that should be 3, 4, and so forth. If other DH-485 nodes are needed (i.e. DTAM, etc...), the AdaptaScan node number(s) must be first. Node gaps must be avoided in order to prevent the AdaptaScan from Soliciting of Successor (SOS). By preventing SOS, bar code throughput is maximized as it is sent to the SLC. In other words, when setting up the AdaptaScan via DH-485 the first priority is to process bar code data instead of finding node gaps.

Publication 2755-6.8.1

Page 34

34

Bar Code Readers Application Guide

Connecting Readers to SLC 5/03 Controller You must use a link coupler if the distance between the reader and the SLC is greater than 15.2 meters (50 feet). The reader can connect directly to another RS-485/RS-422 device. Point-to-point and network connections are the same. The end devices on the DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. AdaptaScan Wiring Base RS-422/RS-485 Terminal RS-485/422 RS-485/422

SLC 5/03 Processor

RS-422 RS-422

Power

Ground

Supply

Shield

Termination Switch 1747-AIC Module Term A B Com Shield Chassis Gnd

Computer

1747-PIC 2755-ASN AdaptaScan Software SLC 500 Advanced Programming Software

Publication 2755-6.8.1

Page 35

Bar Code Readers Application Guide

35

Connecting Readers to SLC 5/04 Controller – 2 AIC Modules The SLC 5/04 controller requires two 1747-PIC converters and a power supply to connect to the second 1747-AIC module. The end devices on a DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. SLC 5/04 Processor

Power Supply

Channel 0 RS-232 1747-PIC AdaptaScan Wiring Base RS-422/RS-485 Terminal DH-485

1747-AIC Module Term A B Com Shield Chassis Gnd

1747-AIC Module Term A B Com Shield Chassis Gnd

1747-P4 24V dc Power Supply

The 1747-P4 Power Supply provides power to both 1747-AIC modules (1 AMP, 24V dc). Otherwise use 2 power supplies.

Computer

1747-PIC DH-485

RS-232

Publication 2755-6.8.1

Page 36

36

Bar Code Readers Application Guide

Connecting Readers to SLC 5/04 Controller – 1 AIC Module The SLC 5/04 controller requires two 1747-PIC converters. However, you can use an RJ48 Y adapter (8-wire LAN phone jack plug) to connect the two 1747-PIC modules. The RJ48 Y adapter is a modular adapter for 4-pair cable which parallels two 4-pair jacks and one 4-pair modular plug. This adapter eliminates the second 1747-AIC module shown in the previous SLC 5/04 network diagram. The end devices on a DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. SLC 5/04 Processor

Power Supply

Channel 0 RS-232 1747-PIC AdaptaScan Wiring Base RS-422/RS-485 Terminal DH-485

1747-AIC Module Term A B Com Shield Chassis Gnd

RJ48 Y Adapter (8-wire LAN Phone Jack Plug) Available from Anixter Company Part No: Hubbell BR851-B Phone: 414-355-0222

Computer

1747-PIC DH-485

Publication 2755-6.8.1

RS-232

Page 37

Bar Code Readers Application Guide

Configuring Bar Code Reader 1

37

This section shows how to configure one the AdaptaScan Bar Code Readers using the AdaptaScan Software (Catalog No. 2755-ASN). The procedures in this section show how to: • configure a bar code label and symbol • define the DeviceNet node address of the AdaptaScan Reader • configure the scanner • configure the decoder trigger • configure the serial port • configure the format of messages and the message destination The steps may vary for some procedures because of the different requirements of applications. For example, the bar code labels may vary from one application to the next.

Create a New Project Create a new project named DH485 Setup for the AdaptaScan Bar Code Readers. 1. Choose New from the Project menu to create a new project. 2. Click the New button to add a bar code reader (Bar Code Reader 1) to the project.

Publication 2755-6.8.1

Page 38

38

Bar Code Readers Application Guide

3. Choose Edit from the Project menu to rename the project DH485 Setup.

4. Click Save to save the project under the new name and then Close to return to the Project dialog.

Define the Bar Code Label 1. Click the Label button to open the Bar Code Labels dialog.

2. Click the New button to add a label to open the Bar Code Label dialog.

3. Click the New button to add a symbol.

Publication 2755-6.8.1

Page 39

Bar Code Readers Application Guide

39

4. Select a symbology and any other parameters (Identifier, Lengths) required by your application.

5. Click OK to return to the main Project dialog.

Define the DeviceNet Address 1. Click the Device button to open the Device dialog.

2. Select a DeviceNet address. Note: The DeviceNet address is not always the same as the DH-485 node address. A DH-485 node address is assigned later. 3. Connect the 2755-NC43 or -NC48 cable to the reader. 4. Click the Apply button. 5. Click Save and Close to return to the Project dialog.

Publication 2755-6.8.1

Page 40

40

Bar Code Readers Application Guide

Configure the Scanner 1. Click the Scanner button on the Project dialog to open the Scanner dialog.

2. Configure the scan pattern and use the Focus procedure for optimum scanner focus. Use the Apply button to send the scanner configuration to the AdaptaScan. 3. Click the Close button and return to the Project dialog.

Configure the Decoder Trigger This application uses a Timer to trigger the reader’s decoder. The Timer is typically used during application setup. Refer to Publication 2755-837 for other input sources that trigger the decoder. 1. Click the Decoder button from the main Project dialog. 2. Under Triggered By, select Timer from the Input list.

3. Click Save and Close to return to the main Project dialog.

Publication 2755-6.8.1