The text of a manual · part 4 of 6
AdaptaScan Bar Code Readers Application Guide Document Update: Chapter 17 - Communicating with PanelView 900 Terminals on a DeviceNet Network
Pages 27 to 31 of 48, from AdaptaScan Bar Code Readers Application Guide Document Update
The original document is the PDF (529 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 27
Bar Code Readers Application Guide
Chapter 17 – Communicating with PanelView Terminals on a DeviceNet Network
27
Under AdaptaScan Application, the sections are: This application provides an example of using explicit-client messages to monitor decoded bar code data and change attributes of an AdaptaScan Bar Code Reader. The AdaptaScan is connected directly to the Power Supply (Catalog No. 2755-PW46)
AdaptaScan Reader
PanelView 900
The DeviceNet network must be supplied with power. In this application, you can use the AdaptaScan power supply (Catalog No. 2755–PW46). The power supplies used with DeviceNet are sized to the number of devices and DeviceNet cable lengths. Review your DeviceNet literature for DeviceNet network configuration data. Note: AdaptaScan software version 11.x or later with reader firmware 11.x or later is required to run this application.
Connections The PanelView connects directly to the DeviceNet terminal block in the AdaptaScan wiring base. Refer to Publication No. 2755-837 for DeviceNet and power supply connections.
Publication 2755-6.8.1
Page 28
28
Bar Code Readers Application Guide
PanelView Screen The following shows how the PanelView screen appears in (Catalog No. 2711-ND3). You will need to create this screen for your application.
In this application, the PanelView terminal: • displays decoded bar code data and package count from the AdaptaScan Reader • resets the package count
Publication 2755-6.8.1
Page 29
Bar Code Readers Application Guide
29
Read Bar Code Data and Package Count Tag Configuration The dialog box for the bar code display object is shown below. The display is configured as an ASCII string with an embedded variable (bar code data) and package count. The Field Width is set to 24 characters and is based on the expected maximum bar code data length in characters plus 10 character package count. The tag name is Bar_Code_Data.
By selecting the Edit Tag option, you can edit the tag data as shown below.
4 2 3
The tag data type is “Character Array”. It is an explicit-client read message with the Class, Instance and Attribute values as shown. To read bar code data and package count, the bit offset must be set to 16. The offset is necessary since the first two bytes represent the length of the requested data.
Publication 2755-6.8.1
Page 30
30
Bar Code Readers Application Guide
AdaptaScan Configuration The AdaptaScan Reader must be configured to make data available for the PanelView terminal. You must configure the AdaptaScan Reader for the bar code symbology being read, the number of bar codes, scan pattern and triggering as you would for any other application. Refer to Publication No. 2755-838 for information regarding the basic set up of the AdaptaScan Bar Code Reader. The following sections only provide the information necessary to make the data available for the PanelView terminal.
Making Bar Code Data Available To make the bar code data available on DeviceNet, the AdaptaScan Bar Code Reader must be configured to make the data available. The two dialog screens shown below set up a message field that contains the bar code data. See Publication No. 2755-838. The fields containing Symbol 1, Symbol 2, Symbol 3, define three bar code types configured for the AdaptaScan Reader.
Publication 2755-6.8.1
Page 31
Bar Code Readers Application Guide
31
Making Package Counter Data Available Package counter data must be made available to the PanelView terminal by setting up an unconditional match in the AdaptaScan Bar Code Reader. The figure below shows the two dialog boxes that need to be modified.
Publication 2755-6.8.1