Page 73
Maintenance and Troubleshooting
5–11
3. Slide the battery pack out from the handle.
Handle Release Button Battery Pack
4. Insert the new battery into the scanner handle. Make sure the handle release button is pressed in below the outer housing when sliding a charged battery into place. 5. Pair the scanner with the base/charger unit. Refer to page 2–16 for information regarding pairing the scanner to the base/charger unit.
Publication 2755-6.3
Page 74
5–12
Maintenance and Troubleshooting
Cleaning the Scan Window Carefully clean the window by first removing loose particles of dirt with clean air. Then use an optical quality cloth moistened with an optical quality cleaning fluid for plastic lenses and wipe the window in a single direction (don’t wipe cloth back and forth across window). Do not leave streaks.
!
!
ATTENTION: Do not use abrasive materials such as disposable wipes and facial tissue. Do not use solvents like alcohol or acetone. These materials will damage the window and the finish on the scanner.
ATTENTION: The scanner has no serviceable parts. Do not open the housing of the scanner.
Publication 2755-6.3
Page 75
Maintenance and Troubleshooting
5–13
Troubleshooting the Scanners The following table provides a list of the most common operating problems, the probable causes, and suggested corrective actions. Problem
No Scan Beam
Weak Scan Beam
Probable Cause(s)
Corrective Action
1. Power supply not connected to base/charger unit or power source.
1. Make sure power supply is connected to the base/charger unit and plugged into a power source.
2. Depleted battery.
2. Recharge battery.
3. Scan beam has timed out.
3. Normal operation. Release trigger completely and scan again.
4. Defective scanner.
4. If possible, try another scanner using the same connections. Contact Allen-Bradley Global Technical Services (GTS).
1. Depleted battery.
1. Recharge battery.
1. Trigger on long range scanner is not fully pressed.
1. Long range scanner has a 2 position trigger. The first position is for the spotter beam. Press the trigger to the next position for scanning.
2. Defective scanner.
2. Contact Allen-Bradley Global Technical Services (GTS).
Scan Beam Appears as a Dot, Not a Line
Table continued on the next page.
Publication 2755-6.3
Page 76
5–14
Maintenance and Troubleshooting
Problem
Scan Beam Present, Bar Codes Not Read
Publication 2755-6.3
Probable Cause(s)
Corrective Action
1. Scanner and base/charger unit are not paired.
1. Pair the scanner and base/charger unit together.
2. Scanner out of transmission range.
2. Move scanner closer to base/charger unit.
3. Scanner not held at slight angle to the bar code.
3. Hold scanner at an angle to the bar code.
4. Scanner not programmed to read the type of bar code you are scanning.
4. Make sure the scanner is configured for the type of bar code symbols you are scanning.
5. Scan beam not crossing entire symbol.
5. Make sure scan beam crosses every bar or space on the symbol.
6. Poor quality bar code symbols.
6. Use the symbols provided on the inside back cover for testing.
7. Loose cable connections.
7. Check for loose cables/ improper connections.
Page 77
Maintenance and Troubleshooting
5–15
Troubleshooting the 4-Slot Battery Charger The following LEDs and tables provide you with information regarding troubleshooting the 4-slot battery charger. 4-Slot Battery Charger LED Status Each charging station has its own status display to inform you of the station’s status as shown below.
LED
Color
Charge
Yellow
Status
Indicates
Solid
Battery is charging.
Flashing
Battery is conditioning.
Ready
Green
Flashing
Station has charged battery to 95% capacity.
Rejected
Red
Flashing
Faulty battery.
Power
Green
Solid
Power is applied to battery charger.
Publication 2755-6.3
Page 78
5–16
Maintenance and Troubleshooting
Identifying 4-Slot Battery Charger Errors The following table provides a list of the most common operating problems, the probable causes, and suggested corrective actions. Problem
Power Indicator on Battery Charger is Not Lit (all stations)
Power Indicator on Battery Charger is Not Lit (single station)
Station Rejected Indicator is Lit (red flashing)
Station is Ready in a Short Period of Time Table continued on the next page.
Publication 2755-6.3
Probable Cause(s)
Corrective Action
1. Power supply cord is not connected to power receptacle.
1. Check connection.
2. Power supply cord not connected to the battery charger.
2. Check connection.
3. Faulty power supply or 4-slot battery charger.
3. Replace the power supply or the 4-slot battery charger. Contact Allen-Bradley Global Technical Services (GTS).
1. Faulty charging station.
1. Use a different charging station.
2. Faulty LED.
2. Use a different charging station.
1. Faulty condition identified.
1. Remove battery from the battery adapter. Reinsert the battery adapter into the battery charger.
2. Over discharge of battery occurred.
2. Allow battery adapter to sit in the battery charger for 15 minutes and then reinsert the battery into that battery adapter.
3. Defective battery.
3. Replace the battery.
1. Battery is fully charged.
1. None needed.
2. Faulty battery.
2. Recharge or replace the battery.
Page 79
Maintenance and Troubleshooting
Problem
Probable Cause(s)
5–17
Corrective Action
1. Battery charger is not seated properly on the battery charger.
1. Reseat the battery adapter.
2. Defective battery adapter.
2. Replace the battery adapter.
Station will not go into Charge 3. Defective battery. Mode (yellow solid indicator) 4. Battery is not the proper temperature.
3. Replace the battery. 4. Allow the battery adjust to room temperature.
5. Faulty LED on battery charger.
5. Contact Allen-Bradley Global Technical Services (GTS).
1. Battery is too hot.
1. Allow battery to cool down.
2. Battery is already discharged.
2. Charge battery.
3. Faulty LED.
3. Contact Allen-Bradley Global Technical Services (GTS).
Battery Becomes Hot
1. Battery is defective.
1. Replace battery immediately.
Power Supply Shuts Down Temporarily
1. Power line surge.
1. Power is automatically reset.
Station will not go into Condition Mode (yellow flashing indicator)
Publication 2755-6.3
Page 80
5–18
Maintenance and Troubleshooting
Listening for an Audible Response When scanning a bar code symbol, you hear beeps from the scanner. Refer to the following tables to determine the meaning of the beeps. Beep During Normal Operation This Response
Indicates
1 Beep (short–high tone)
Bar code symbol is decoded. Scanner audible response must be enabled.
2 Beeps (long–high tone)
Mismatch between the selected host and interface cable.
4 Beeps (long–high tone)
Format or transmission error detected. This error occurs if the scanner is not properly configured. Verify option settings.
5 Beeps (long–high tone)
Data conversion error detected. This error occurs if the Ignore Unknown Characters is disabled when attempting to transmit data not supported by the selected host.
6 Beeps (short–low tone)
RF out of range error detected. The scan did not register with the base/charger unit.
Beep During Entering Parameter Bar Codes This Response
Indicates
1 Beep (short–high tone)
Bar code symbol is accepted. Scanner audible response must be enabled.
1 Beep (low–high tone)
Input error. Possible causes: •Incorrect bar code scanned •Cancel scanned •Incorrect configuration sequence
1 Beep (high–low tone)
Keyboard parameter selected. Scan the appropriate bar code.
1 Beep (high–low–high–low tone)
Successful program exit with change in the parameter setting.
Publication 2755-6.3
Page 81
Maintenance and Troubleshooting
5–19
Beep During Code 39 Scan and Store This Response
Indicates
1 Beep (high–low tone)
New Code 39 data was entered into the buffer.
3 Beeps (long high tone)
Code 39 buffer is full.
1 Beep (low–high–low tone)
Attempt to transmit or clear an empty buffer occurred. When the Code 39 buffer was empty, the base station read a command to clear or to transmit a Code 39 buffer.
2 Beeps (long high tone)
Error in data transmission.
1 Beep (low–high tone)
Buffer data transmission successful.
Contacting Allen-Bradley Global Technical Services If you should require assistance or need additional information on operating the scanners, contact Allen-Bradley Global Technical Services (GTS) at (216) 646-6800.
Publication 2755-6.3