Page 63

Chapter

5

Maintenance and Troubleshooting This chapter describes how to maintain and troubleshoot the scanners. Topics include: • charging the battery • conditioning the battery • changing the battery pack in the scanner gun • cleaning the scan window • troubleshooting the scanners • troubleshooting the 4-slot battery charger • listening for audible responses • contacting Allen-Bradley Global Technical Services

Publication 2755-6.3

Page 64

5–2

Maintenance and Troubleshooting

Charging the Battery You can charge the battery (Catalog No. 2755-HCP-B1) while the battery is in the gun or in the 4-slot battery charger.

!

ATTENTION: Charge a battery at room temperature of 65_ F (18.3_ C) to 70_ F (21.1_ C) for optimum performance. Allow the battery to adjust to room temperature before charging.

In the Gun 1. Connect the power supply to the power input port on the base/charger unit. Base/charger Power Input Port Host

Power Supply

Publication 2755-6.3

Page 65

Maintenance and Troubleshooting

5–3

2. Connect the power supply to the appropriate receptacle supplying AC power of the proper voltage level. Power Supply 2755-HCP-D1

Voltage Level 100–240V ac/50–60 Hz

3. Place the scanner into the base/charger unit as shown below. Make sure that the unit fits snugly into the base/charger.

4. Check the charge status indicator for a full charge (blinking rapidly = full charge), which occurs within two hours. However, you can use the scanner with less than a full charge. Charge Status LED

Publication 2755-6.3

Page 66

5–4

Maintenance and Troubleshooting

Base/charger LED Status Red LED

Indicates

Off

The scanner is not properly inserted into the base/charger unit or the battery is not functioning properly.

Blinking Slowly

Battery charge is pending. This occurs if the battery temperature is too high or too low or the battery is deeply discharged. After several minutes, normal charging should begin.

On

The battery is actively charging. Charging takes approximately two hours.

Blinking Rapidly

Battery charging is complete.

Refer to page 5–13 for more information regarding low battery strength. Average life of a battery charge is 8 hours. Refer to page 5–10 for replacing the battery.

Publication 2755-6.3

Page 67

Maintenance and Troubleshooting

5–5

In the 4-Slot Battery Charger Before using the 4-slot battery charger (Catalog No. 2755-HCP-B2), read all the instructions and cautionary markings on the 4-slot battery charger, battery, and on any products that use the battery.

!

ATTENTION: To reduce the risk of injury, use the 4-slot battery charger only in the way it is intended to be used. Other batteries or adapters may explode causing personal injury and damage.

To help insure proper operation of the 4-slot battery charger and batteries, refer to the following. • Do not expose the battery charger to rain, snow, or direct sunlight. • The battery charger can be used at 32_ F to 104_ F (0_ C to 40_ C). • The battery charger should be placed in a well ventilated area free of airborne contaminants. • Unplug the battery charger from the receptacle supplying AC power before attempting to clean or change adapters in order to reduce the risk of electrical shock. • Dispose of dead batteries in accordance with all applicable codes. • Do not disassemble, incinerate, modify, or short circuit batteries, charger, or related components. • Perform a battery conditioning cycle on all new NiCd batteries before using to ensure that the battery is fully charged. Refer to page 5–9 to condition a battery. To charge the battery in the 4-slot battery charger: 1. Mount the 4-slot battery charger horizontally as shown below.

Publication 2755-6.3

Page 68

5–6

Maintenance and Troubleshooting

2. Connect the 4-slot battery charger power supply to the 4-slot battery charger. 4-Slot Battery Charger

To Battery Charger

Battery Charger Power Supply

3. Connect the power supply cable to the battery charger power supply and to the outlet supplying AC power. Make sure the outlet box is properly grounded. If you are not sure, have the outlet checked by a qualified electrician. To Power Receptacle To Battery Charger Power Supply Grounding Pin

Publication 2755-6.3

Page 69

Maintenance and Troubleshooting

5–7

The power supply manages and conditions the power input to the charger, eliminating the need for a replaceable fuse. Should a power surge occur, the power supply connected to the charger temporarily interrupts the current supply until the condition is corrected. If an extreme surge occurred, the power light on the power supply remains off and the power supply needs to be replaced. 4. Attach the battery adapter (Catalog No. 2755-HCP-B3) to the battery charger by aligning the adapter to the charger and sliding the adapter downward, locking into place. Battery Adapter

4-Slot Battery Charger

To remove the adapter, push the tab up and slide the adapter outward. Tab

4-Slot Battery Charger

Publication 2755-6.3

Page 70

5–8

Maintenance and Troubleshooting

5. Insert a depleted battery into an adapter that is inserted into the 4-slot battery charger. Press the handle release button in as you are sliding the battery into the adapter. Battery Handle Release Button

Battery Adapter

4-Slot Battery Charger

Charging Station

If you are charging a new battery pack, the battery charger may prematurely switch to ready. If this occurs, remove the battery from the adapter and reinsert. Upon completion of a battery charge, the READY LED on the battery charger will flash. This indicates the battery is 95% charged. For 100% charge, leave the battery on the charger for 3 hours. A fully charged battery can be left on the battery charger indefinitely. The battery charger maintains the battery at 100% of its rated capacity.

Publication 2755-6.3

Page 71

Maintenance and Troubleshooting

5–9

Conditioning the Battery If you are using a battery for the first time or notice a decrease in battery life: 1. Insert the battery into an adapter on the 4-slot battery charger. 2. Depress the PRESS TO CONDITION button for two seconds on the 4-slot battery charger.

PRESS TO CONDITION Button

Pressing the PRESS TO CONDITION button performs a complete discharge of the battery and will recharge the battery to full capacity. Conditioning eliminates the situations that may cause the battery to deliver less than its rated capacity. Conditioning may take 3–6 hours. Publication 2755-6.3

Page 72

5–10

!

Maintenance and Troubleshooting

ATTENTION: Perform the conditioning cycle when the battery is new or shows decreased life. Conditioning batteries more often will shorten battery life.

If conditioning the battery is not successful as indicated by the flashing REJECTED indicator on the battery charger, your battery needs replacement. Contact your local Allen-Bradley distributor for ordering a new battery.

Changing the Battery Pack in the Scanner Gun 1. Locate the handle release button on the scanner.

Handle Release Button Battery Pack

2. Press in the handle release button below the outer housing with a probe.

Publication 2755-6.3