Page 82

Appendix

A

Specifications This appendix lists the specifications for the: • scanners • 4-slot battery charger • power supply • base/charger unit

Scanner Specifications

Description

Specification Standard Range Long Range (Catalog (Catalog No. No. 2755-HCG-7) 2755-HCG-4)

Power Requirements

4.75V dc to 14V dc: 210 mA @ 5V dc typical

Scan Repetition Time

Approximately 36 (±3) scans per second (bidirectional)

Start-up Time

<50 msec from scan enable

Data Acquisition Time

<110 msec from scan enable

Skew Tolerance

± 55_ from normal

± 60_ from normal

Pitch Angle

± 65_ from normal

± 45_ from normal

Decode Depth of Field

See page 1–6

See page 1–6

Minimum Element Width

0.005 in. (0.127 mm)

0.007 in. (0.178 mn)

Maximum Element Width

0.2 in. (5.08 mm)

Print Contrast Minimum

20% absolute dark/light reflectance differential, measured @ 675 nm

50% absolute dark/light reflectance differential, measured @ 675 nm

Table continued on the next page.

Publication 2755-6.3

Page 83

A–2

Specifications

Standard Range (Catalog No. 2755-HCG-4)

Description Frequency Control

Programmable Synthesizer

Frequency Range

2.4 to 2.5G Hz

Frequency Resolution

250K Hz steps

Frequency Stability

± 20 ppm

Conducted RF Power Output

10 dBm

Radiated RF Power

1 mW (<50 mV/m @3m)

Output Bandwidth

250K Hz @ – 3 dB 500K Hz @ – 20 dB

Long Range (Catalog No. 2755-HCG-7)

Ambient Light Immunity Artificial Lighting

450 ft candles (4844 lux)

Sunlight

8000 ft candles (86112 lux @8 in. on low density bar codes)

Durability

6 ft (8 m) drop to concrete

Operating Temperature

32_ F to 104_ F (0_ C to 40_ C)

Storage Temperature

-40_ F to 140_ F (-40_ C to 60_ C)

Humidity

5 to 95% noncondensing

Height

6.3 in. (16 cm)

Length

5 in. (12.7 cm)

Width

2.8 in. (7.1 cm)

CDRH Class

I, II

Agency Certification

• CSA certified • UL listed

Publication 2755-6.3

8000 ft candles (86112 lux)

II

Page 84

Specifications

A–3

4-Slot Battery Charger Specifications Description

Specification

Catalog Number

2755-HCP-B2

Operating Temperature

32_ F to 104_ F (0_ C to 40_ C)

Storage Temperature

-40_ F to 140_ F (-40_ C to 60_ C)

Humidity

5 to 95% noncondensing

Agency Certification

• cUL listed • UL listed • TUV EN 60950 approved

Power Supply Specifications Description

Specification

Catalog Number

2755-HCP-D1

Input Range

100–240V ac/50–60 Hz

Output Range

5V dc @ 3 A 12V dc @ 1 A

Operating Temperature

32_ F to 104_ F (0_ C to 40_ C)

Agency Certification

• CSA certified • UL listed • CE marked for all applicable directives. • TUV EN 60950 approved

Publication 2755-6.3

Page 85

A–4

Specifications

Base/Charger Unit Specifications Description

Specification

Catalog Number

2755-HCG-B

Power Requirements

5V dc ± 10% @ 190 mA typical 12V dc ± 10% 400 mA typical

Sensitivity

–94 dBm 10E–4 BER

Selectivity

250K Hz @3 dB points 1 MHz @ 50 dB points

Frequency Control

Programmable Synthesizer

Frequency Range

2.4 to 2.5G Hz

Frequency Resolution

250K Hz steps

Frequency Stability

± 20 ppm

Durability

6 ft (8 m) drop to concrete

Operating Temperature

32_ F to 104_ F (0_ C to 40_ C)

Storage Temperature

-40_ F to 140_ F (-40_ C to 60_ C)

Humidity

5 to 95% noncondensing

Agency Certification

• CSA certified • UL listed