Page 20

Configuring your Reader

2–9

Miscellaneous Type

Description

1, 2, 4 and 8 Compare Buffers

The option selected here determines how many bar codes are buffered in reference to same symbol comparisons. This value should always be equal to or greater than the number of different bar codes you expect to scan on each package to avoid the potential of double reads.

Scan Count

When this option is enabled, the reader enters scan count test mode. Do not enable this feature unless instructed to do so by a Rockwell Automation representative.

Reverse LED convention

Normal LED convention calls for the red LED to signify power/ready to scan and the green LED for transmit indicator. When this option is enabled, the functions of the two LED’s are switched.

Support multiple beep ‘B’/ razz ‘Z’ commands

When this option is enabled, the reader recognizes a multiple beep/razz command from the host. The command is a number, from 1 to 9, followed by an ASCII ‘B’ or an ASCII ‘Z’.

Support host BEL/CANCEL commands

When this option is enabled, the reader beeps when it receives a BEL (07H) command from the host. If ACK/NAK is enabled, a BEL command causes the reader to beep 3 times, if sent first after a bar code is transmitted. Or it will cause the reader to beep once if ACK/NAK is not enabled. If a CAN (18H) command is sent from the host, the reader exits out of its communication loop without a beep and clears all buffers.

Enter program mode only after power-up

Normally, you may enter Program Mode at any time. When this option is enabled, you are restricted to entering Program Mode, between initial power–up and before your first scan only. If you select this option and need to modify the reader parameters after several scans, merely power–down and power–up the reader again. Then enter into Program Mode before scanning again.

Enable status reporting

When this option is enabled, the host can initiate a status report download from the reader with a CTRL P command (10H). Status information includes motor status, laser status, decode board status, scan counts per field since last power-up, slave status and non-volatile memory status.

Number of good scans required (1–8)

This number, from 1 to 8, is a redundancy counter which refers to the number of times the reader must scan a bar code, before it considers it a good scan and transmits the bar code. The default of 1 is usually fine for most symbologies. Values greater than 1 may be needed when data integrity is most critical. Note that as the number of good scans required is increased, aggressiveness will decrease.

Table continued on the next page.

Publication 2755-6.14

Page 21

2–10

Configuring your Reader

Miscellaneous Type

Publication 2755-6.14

Description

Special code select

When this option is enabled and the Enter key is hit on this choice, a custom reader parameters window appears. This window allows you to select up to 5 code and length–specific code selects. The reader only scans those codes at the programmed lengths entered here. When used in conjunction with Package Detect and multiple scans per activation, the reader scans and buffers the programmed bar codes. It transmits them in the order that they were programmed within the window. See Package Detect and Multiple Scans per activation for more details. Use the arrow keys to move around the screen. Use the Enter key to save the current code select choice and advance to the next choice. Use the backspace key to go back to the previous choice. Hit F10 to save these settings and return to the configuration screen or hit Escape to exit without saving changes.

Normal/Loud Volume

Select the desired loudness with these 2 options.

Support ‘M/O’ motor on/off commands

When this option is enabled, the reader accepts ‘M’ motor on and ‘O’ motor off commands from the host. The motor off command causes the lasers to go off, the motor to shut down, and the power LED to go off. A motor on condition turns the motor back on and the power LED to come on. The lasers do not turn on until the motor comes up to full speed (approx. 45-50 seconds).

Support non–decode hand–held port

This option enables the reader to support an undecoded hand–held reader connnected the hand–held port. When this option is enabled, the HH (Hand– Held reader option) window at the bottom of the configuration screen displays all currently supported Hand–Held options.

Page 22

Configuring your Reader

2–11

Package Detect This section provides you with all the choices currently supported for Package Detect options. Special software is not required to support the following options. The appropriate hardware comes standard internal to the 2755-LHB-1 Interface Box and reader. The hardware interfaces with up to 2 Package Detect inputs and an Output/Alarm Output.

Publication 2755-6.14

Page 23

2–12

Configuring your Reader

Output/Package Detect Type

Support package detect

Support package detect alarm input

When this option is enabled, the reader produces a steady stream of beeps, if the sensor alarm is activated.

Transmit ‘No Read’ message on package detect timeout

When this option is enabled, the reader transmits ‘NO READ’ if a no read condition occurs. If a custom message is desired, refer to programmable no read message (see below). This function also supports the following prefixes and suffixes: TAB prefix, CR, LF, ETX, STX, programmable prefixes and suffixes, and TAB suffix.

Scans per package detect activation (1-5)

This option allows you to determine how many different bar codes the reader expects to see per sensor activation. To avoid multiple reads of the same bar code, make sure the same symbol timeout is set accordingly and the number of scan buffers is equal to or greater than this number.

Scanner activation time after package detection (sec)

Support Package Detect must be enabled first before a value can be entered here. The value here determines how long the reader will look for a bar code before timing out. If the value is less than 9 seconds (minimum of .1 seconds), the reader will be active for this amount of time. If the value is greater than 9 seconds, the reader remains active as long as the Package Detect is active. If dual line sensor is enabled, this value is forced to 9.9 seconds.

Support AC output

When this option is enabled, the reader will activate the output according to the selections below.

Table continued on the next page.

Publication 2755-6.14

Description When this option is enabled, scanning is disabled until a Package Detect activation is detected. In the first mode, if the scan duration (see below) is set for less than 9 seconds, the reader is active for scanning for the programmed scan duration. In the second mode, if scan duration is set for greater than 9 seconds, the reader is active for scanning as long as the sensor remains active. After a scan cycle completes, the sensor must turn off momentarily before the next valid activation is recognized. In the third mode, dual line sensor support, this value is automatically set to 9.9 seconds.

Page 24

Configuring your Reader

2–13

Output/Package Detect Type

Description

AC output Controlled by Host (DC2/DC4)

When this option is enabled, the host assumes full control for activating and deactivating the Output. To turn the Output on, the host must send a CTRL R (12H) character. To turn the Output off, the host must send a CTRL T (14H) character. The support Output option must be enabled first in order to select this option.

AC output Normally On

The default mode of the reader is to have the Output normally off. When this option is enabled, the Output is normally on.

Enable Read and Match mode

This option is an Output function. Support Output must be enabled before this option is valid. When this option is enabled, the reader stores in memory the next bar code it reads after either powering–up or after being programmed via StrataSet. The reader emits a unique beep sequence as an indicator that it’s taking the bar code as a read and match bar code. From that point on, the Output operates according to whether output on good read/match is enabled or output on bad match is enabled. Normally, if this option is enabled, a new read and match bar code is stored after each power-up and after each StrataSet programming session. If desired, you may enable save read and match bar code (see below) to preserve the read and match bar code, if power is lost.

Activate AC output if good read/match

This option is an Output function. Support Output must be enabled before this option is valid. When this option is enabled, if read and match is enabled (see above), this feature reads “Output on a good match”. The Output will turn on every time a scanned bar code matches the read and match bar code. If read and match is not enabled, the feature reads “fire Output on good read”. The Output turns on every time the reader scans a good read.

Activate AC output if bad match

This option is a read and match function as well as an Output function. Both options must be enabled before this option is valid. When this option is enabled, the Output turns on every time a scanned bar code does not match the read and match bar code. See Enable read and match option above for details on setting up for read and match mode.

Activate AC output if no read

This option is a Package Detect function as well as an Output function. Both options must be enabled before this option is valid. When this option is enabled, the Output will turn on if a no read condition occurs. A no read condition occurs if the reader reaches a sensor timeout before a bar code is scanned (see support Package Detect) It also occurs if the line sensor turns off before a bar code is read (if scan duration is greater than 9 seconds).

Table continued on the next page.

Publication 2755-6.14

Page 25

2–14

Configuring your Reader

Output/Package Detect Type AC output Duration (sec)

Delay Time before activating AC output (sec)

The value entered here determines how long the reader delays after its normal activation time before acivating the output. The default value of 0.0 should be sufficient for almost all applications. Use this option only if it is impossible to mount the reader at the Output location.

Enable programmable ‘No Read’ message

When this option is enabled, you will be able to program your own no read message. The message can be up to 10 characters long and can include any of the human readable ASCII set (20h to 7fh). Note that the message is right–justified when transmitted from the reader. If this option is being used with Wand Emulation output, the reader defaults to output as Code 39 so the message must be within the normal Code 39 range of characters.

Retain same symbol timers after package detect cycle ends

Under normal Package Detect support conditions, the reader resets scan buffers after a complete sensor cycle. Same symbol timers prevent multiple reads during the scan cycle. But as soon as the cycle completes and the next Package Detect is recognized, all buffers are cleared and the reader scans any bar codes in the field. When retain same symbol buffers with Package Detect is enabled, same symbol timers do not automatically reset after a completed sensor cycle. Rather, they reset after the same symbol timer times out. This feature can be useful under these 3 conditions: packages are spaced relatively closely, the bar codes on consecutive packages are the same and the possibility of a package triggering a Package Detect while the box is still in the scan field exists.

Save read and match bar code if power–down

Under normal operations, when read and match mode is used, a new read and match bar code is stored immediately after the reader has been powered–up or after the reader has been programmed through StrataSet. When save read and match bar code on power–down is enabled, the read and match bar code is saved during a power-down, and a new read and match is only accepted after programming the reader.

Support dual package detect inputs

When this option is enabled, the reader uses the current line sensor ALARM input as the second Package Detect input. The current line sensor input acts as the start of activation cycle, and the second Package Detect input acts as the end of activation cycle.

Table continued on the next page.

Publication 2755-6.14

Description The value entered here determines how long the Output/alarm output remains active.

Page 26

Configuring your Reader

Output/Package Detect Type

2–15

Description

Buffer scans until package detect cycle completes

StrataScan Readers have the ability to buffer all bar codes as they are scanned (with Package Detect support enabled). If this option is enabled, all scanned bar codes are buffered during the active sensor cycle and are not transmitted, until the activation cycle has completed. This feature is supported with all 3 Package Detect mode options. If this feature is not enabled, all scanned bar codes are transmitted as they are scanned. This option does not apply to the special code select feature, which always buffers incoming bar codes.

Enable host package detect emulation

When this option is enabled, the host simulates the Package Detect input(s) by sending an ‘S’ (53h) character and an ‘X’ (58h) character. If dual Package Detects is enabled, the ‘S’ simulates the Package Detect input 1 and the the ‘X’ simulates the Package Detect input 2. If a finite scan duration is being used, the ‘S’ character starts the cycle. If scan duration > 9 seconds (reader active until the sensor goes away), the ‘S’ starts the cycle and the ‘X’ ends the cycle.

Scan Range This section provides depth of field options. Long depth of field should be enabled in all StrataScan Readers. The 2 reserved options are not currently supported and are reserved for future use.

Publication 2755-6.14

Page 27

2–16

Configuring your Reader

Reserve Codes This section provides 98 reserved functions available to enable future special software features. Do not enable any reserve codes unless told to do so by a company representative.

RS232 Format This section provides you with all the interface format–specific options. If RS232 is selected in the Interface Format menu, these menus are displayed as RS232 specific menus.

Publication 2755-6.14