Page 28
Configuring your Reader
2–17
Baud Rate Rate Baud Rate
Description Data is transferred at either 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 baud.
Data Format These choices represent the parity of the data byte. Parity is an extra bit attached to the transmitted data byte and is used to catch potential single-bit data transmission errors. The reader’s parity must match the host’s parity.
Publication 2755-6.14
Page 29
2–18
Configuring your Reader
RS232 Type Data Format
Description
Odd
Select odd to make the parity bit either a 0 or 1, to guarantee an odd number of ones.
Space
Select space to make the parity bit always 0.
Even
Select even to make the parity bit either a 0 or 1, to guarantee an even number of ones.
Mark
Select mark to make the parity bit always 1.
None
Select none and the parity bit time is skipped.
7 or 8 Data Bits
Select between 7 and 8 data bits per data byte, depending on the requirements of your host.
1 or 2 Stop Bits
Select between 1 and 2 stop bits per data byte, depending on the requirements of your host.
Note: The StrataScan line of Readers supports either 10 or 11 bit data words. You cannot choose a data byte format that is not either 10 or 11 data bits total (including 1 start bit). For example, you cannot select 7 data bits, 1 stop bit and no parity, since this would constitute a 9-bit data byte. You cannot choose 8 data bits, 2 stop bits and a parity bit, since this would constitute a 12-bit data byte, including 1 start bit.
Further RS232 Options RS232 Type Options
Publication 2755-6.14
Description
Reserved 1
This option is reserved for future use.
Reserved 2
This option is reserved for future use.
ACK/NAK
After a bar code is scanned and transmitted, if ACK/NAK is enabled, the reader waits for one of several host character commands to be sent from the host. If the host sends an ACK (06H) acknowledge command, the reader beeps and resumes scanning. If the reader receives a NAK (15H) negative acknowledge command, the reader re-transmits the bar code without a beep and does not resume scanning.
CR
When this option is enabled, the reader transmits a Carriage Return after each bar code.
LF
When this option is enabled, the reader transmits a Line Feed after each bar code.
DTR Support
When this option is enabled, the reader requires a Data Terminal Ready (DTR) signal to be present before scanning.
Page 30
Configuring your Reader 2-19
‘4 STRATCFG
[ano =) C3[es|ee) 63) ef Al
INTERFACE CODE SUPPS MISC. PACKAGE SCAN RANGE RESERVE FORMAT TYPES DETECT CODES
RS232/422 Yes Ho Yes Ho Long Ho RS232 FORMAT FORMATTING LENGTH SPECIFIERS I20f5 Others Baud Data Format Options UPC HonUPC Locks Min Lock
9600 Yes res Yes Ho 14% O 4 0
BEEPER SAME SYM heserved
TONE LED TIME OUT heserved
Behl handshaking LF
DTR support
Nixdorf ID
RTS/CTS handshaking RTS/CTS Ccharacter) RTS/CTS (message)
aa
SS
Hormal flash 500 msec HH Port
Yes
Ce | Le | Le Le La
Fi-Help F3-Enter program mode
‘4 STRATCFG
[auto =] a] e3|0e) Gl] sfS Al
INTERFACE CODE SUPPS MISC. PACKAGE SCAN RANGE RESERVE FORMAT TYPES DETECT CODES
RS232/422 Yes Ho Yes Ho Long Ho RS232 FORMAT FORMATTING LENGTH SPECIFIERS I20f5 Others Baud Data Format Options UPC HonUPC Locks Min Lock 9600 Yes res Yes Ho 14% O 4 0
BEEPER SAME SYM ] Transmit SANYO ID Chr TONE LED TIME OUT ] SHI Beetle Mode ] ]
French PC Term Xon/Xoff handshaking ] Programmable prefix identifiers kmit (dec) as 1st prefix identifier HH Port Rmit (dec) as 2nd prefix identifier [ ] Programmable suffix identifiers Yes amit (dec) as 1st suffix identifier amit dec) as 2nd suffix identifier +
[ [ [ [ [
Hormal flash 500 msec
Fi-Help F3-Enter program mode
Publication 2755-6.14
Page 31
2–20
Configuring your Reader
RS232 Type Options
Description When this option is enabled, the reader transmits Nixdorf code identifiers before each bar code as follows:
Nixdorf ID
Code
Prefix Code
UPC-E d
UPC-A c
EAN-8 g
EAN-13 h
Code 39 b
Codabar a
Code 93 i
I 2 of 5 e
Code 128 j
RTS/CTS handshaking
When this option is enabled, the reader outputs a Request To Send (RTS) signal and waits for a Clear To Send (CTS) signal before any data is transmitted.
RTS/CTS (character)
When this option is enabled, the reader activates and deactivates its RTS signal after each character it transmits.
RTS/CTS (message)
When this option is enabled, the reader activates and deactivates its RTS signal after each message it transmits.
ETX suffix
When this option is enabled, the reader transmits an End of Text after each bar code.
STX prefix
When this option is enabled, the reader transmits a Start of Text before each bar code.
Tab prefix
When this option is enabled, the reader transmits a TAB before each bar code.
Tab suffix
When this option is enabled, the reader transmits a TAB after each bar code.
UPC prefix
When this option is enabled, the reader transmits a prefix before any UPC/EAN bar codes. The prefixes are A (UPC A), E0 (UPC E), F (EAN 13), and FF (EAN 8).
UPC suffix
When this option is enabled, the reader transmits a suffix after any UPC/EAN bar codes. The suffixes are A (UPC A), E0 (UPC E), F (EAN 13), and FF (EAN 8).
Schlumberger/Shell format
When this option is enabled, the reader transmits an XOR’ed check digit of all the data characters at the end of the data stream.
Table continued on the next page.
Publication 2755-6.14
Page 32
Configuring your Reader
RS232 Type Options
2–21
Description
Transmit AIM ID Character
When this option is enabled, the reader transmits special AIM code identifiers before each bar code as follows: Code
AIM Code ID
UPC-E
]Z0
UPC-E with 2–digit suppl.
]Z0
UPC-E with 5–digit suppl.
]Z0
UPC-A
]Z0
UPC-A with 2–digit suppl.
]Z0
UPC-A with 5–digit suppl.
]Z0
EAN-8
]E4
EAN-8 with 2–digit suppl.
]E4
EAN-8 with 5–digit suppl.
]E4
EAN-13
]E0
EAN-13 with 2–digit suppl.
]E0
EAN-13 with 5–digit suppl.
]E0
Code 39
]A0
Code 39 FA
]A4
Code 39 with MOD 43
]A3
Code 39 with MOD 43 plus transmit CD
]A1
Code 39 Full ASCII with MOD 43
]A7
Code 39 Full ASCII with MOD 43 plus transmit CD
]A5
Codabar
]F0
Codabar with start and stop characters
]F1
Code 93
]G0
I 2 of 5
]I0
I 2 of 5 with MOD 10
]I2
I 2 of 5 with MOD 10 and transmit MOD 10
]I1
Code 128
]C0
Table continued on the next page.
Publication 2755-6.14
Page 33
2–22
Configuring your Reader
RS232 Type Options
Publication 2755-6.14
Transmit Sanyo ID Character
Description When this option is enabled, the reader transmits special code identifiers before each bar code as follows: Code
Prefix Code
UPC-A
C
EAN-8
A0
EAN-13
B
Code 39
A
Codabar
M plus 2–digit hexadecimal representation of the character count
Code 93
L plus 2–digit hexadecimal representation of the character count
I 2 of 5
I plus 2–digit hexadecimal representation of the character count
Code 128
K plus 2–digit hexadecimal representation of the character count
SNI Beetle Mode
This feature is not currently supported.
French PC Terminal Emulation
This feature is not currently supported.
Xon/Off handshaking
When this option is enabled, the reader does not transmit after an XOFF is received. Transmission resumes after an XON is received.
Programmable prefix identifiers
When this option is enabled, one or two programmable prefix ID characters can be assigned and added to the scanned data transmission. To assign the character, refer to the options Xmit (Transmit) as 1st prefix identifier or Xmit as 2nd prefix identifier below.
Transmit as 1st or 2nd prefix identifier
When the Programmable prefix identifiers option is enabled, a programmable prefix ID character can be entered in either of these 2 windows. (The decimal equivalent of the ASCII value of the key pressed is then displayed).
Programmable suffix identifiers
When this option is enabled, one or two programmable suffix ID characters can be assigned and added to the scanned data transmission. To assign the character, refer to the options Xmit (Transmit) as 1st suffix identifier or Xmit as 2nd suffix identifier.
Transmit as 1st or 2nd suffix identifier
When the Programmable suffix identifiers option is enabled, a programmable suffix ID character can be entered in either of these 2 windows. (The decimal equivalent of the ASCII value of the key pressed is then displayed).
Page 34
Configuring your Reader
2–23
Note: The following table of 32 ALT characters can be used along with the above RS232 options as programmable prefix or suffix identifiers. For example, if you wanted to use the carriage return character (CR) as a programmable suffix identifier, select the Programmable suffix identifier as an RS232 choice in the OPTIONS pull–down menu. Then hold down the ALT key and type CTRL M. CONTROL CODES for ALT characters Character
Control Code
Character
Control Code
Character
Control Code
Character
Control Code
NULL
CTRL 2
BS
CTRL H
DLE
CTRL P
CAN
CTRL X
SOH
CTRL A
HT
CTRL I
DC1
CTRL Q
EM
CTRL Y
STX
CTRL B
LF
CTRL J
DC2
CTRL R
SUB
CTRL Z
ETX
CTRL C
VT
CTRL K
DC3
CTRL S
ESC
CTRL [
EOT
CTRL D
FF
CTRL L
DC4
CTRL T
FS
CTRL \
ENQ
CTRL E
CR
CTRL M
NAK
CTRL U
GS
CTRL ]
ACK
CTRL F
SO
CTRL N
SYN
CTRL V
RS
CTRL 6
BEL
CTRL G
SI
CTRL O
ETB
CTRL W
US
CTRL _
Wand Emulation Format If Wand Emulation format is selected in the Interface Format menu instead of RS232/422, then Poll Source, High Output and Options boxes display as Wand Emulation specific options.
Wand Type Poll Source
Description When poll source is enabled, the reader does not scan unless a 5–volt signal is seen on the poll source input.
Publication 2755-6.14
Page 35
2–24
Configuring your Reader
Wand Type
Hi/Output
Wand Type Options
Publication 2755-6.14
Description Under this menu, you may program the reader to transmit as one of either Bars high as Code 39. Spaces high as Code 39. Bars high as scanned or Spaces high as scanned. Select the method that matches your host’s requirements.
Description
Extra Transition before Bar Code
If your host requires it, the reader can output an extra transition before each bar code.
50x or 10x narrow element border
This option selects whether the borders on the transmitted bar code will be 10 or 50 times the size of a narrow element. This value is a function of the size of the narrow element selected below.
1.0, 0.5, 0.3, 0.15 ms narrow element
This option selects the size of the narrow element of the transmitted bar code. All other elements in the bar code are a direct function of this value as dictated by the symbology specification.