Page 28

Configuring your Reader

2–17

Baud Rate Rate Baud Rate

Description Data is transferred at either 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 baud.

Data Format These choices represent the parity of the data byte. Parity is an extra bit attached to the transmitted data byte and is used to catch potential single-bit data transmission errors. The reader’s parity must match the host’s parity.

Publication 2755-6.14

Page 29

2–18

Configuring your Reader

RS232 Type Data Format

Description

Odd

Select odd to make the parity bit either a 0 or 1, to guarantee an odd number of ones.

Space

Select space to make the parity bit always 0.

Even

Select even to make the parity bit either a 0 or 1, to guarantee an even number of ones.

Mark

Select mark to make the parity bit always 1.

None

Select none and the parity bit time is skipped.

7 or 8 Data Bits

Select between 7 and 8 data bits per data byte, depending on the requirements of your host.

1 or 2 Stop Bits

Select between 1 and 2 stop bits per data byte, depending on the requirements of your host.

Note: The StrataScan line of Readers supports either 10 or 11 bit data words. You cannot choose a data byte format that is not either 10 or 11 data bits total (including 1 start bit). For example, you cannot select 7 data bits, 1 stop bit and no parity, since this would constitute a 9-bit data byte. You cannot choose 8 data bits, 2 stop bits and a parity bit, since this would constitute a 12-bit data byte, including 1 start bit.

Further RS232 Options RS232 Type Options

Publication 2755-6.14

Description

Reserved 1

This option is reserved for future use.

Reserved 2

This option is reserved for future use.

ACK/NAK

After a bar code is scanned and transmitted, if ACK/NAK is enabled, the reader waits for one of several host character commands to be sent from the host. If the host sends an ACK (06H) acknowledge command, the reader beeps and resumes scanning. If the reader receives a NAK (15H) negative acknowledge command, the reader re-transmits the bar code without a beep and does not resume scanning.

CR

When this option is enabled, the reader transmits a Carriage Return after each bar code.

LF

When this option is enabled, the reader transmits a Line Feed after each bar code.

DTR Support

When this option is enabled, the reader requires a Data Terminal Ready (DTR) signal to be present before scanning.

Page 30 read from a scan by OCR; it may hold reading errors

Configuring your Reader 2-19

‘4 STRATCFG

[ano =) C3[es|ee) 63) ef Al

INTERFACE CODE SUPPS MISC. PACKAGE SCAN RANGE RESERVE FORMAT TYPES DETECT CODES

RS232/422 Yes Ho Yes Ho Long Ho RS232 FORMAT FORMATTING LENGTH SPECIFIERS I20f5 Others Baud Data Format Options UPC HonUPC Locks Min Lock

9600 Yes res Yes Ho 14% O 4 0

BEEPER SAME SYM heserved

TONE LED TIME OUT heserved

Behl handshaking LF

DTR support

Nixdorf ID

RTS/CTS handshaking RTS/CTS Ccharacter) RTS/CTS (message)

aa

SS

Hormal flash 500 msec HH Port

Yes

Ce | Le | Le Le La

Fi-Help F3-Enter program mode

‘4 STRATCFG

[auto =] a] e3|0e) Gl] sfS Al

INTERFACE CODE SUPPS MISC. PACKAGE SCAN RANGE RESERVE FORMAT TYPES DETECT CODES

RS232/422 Yes Ho Yes Ho Long Ho RS232 FORMAT FORMATTING LENGTH SPECIFIERS I20f5 Others Baud Data Format Options UPC HonUPC Locks Min Lock 9600 Yes res Yes Ho 14% O 4 0

BEEPER SAME SYM ] Transmit SANYO ID Chr TONE LED TIME OUT ] SHI Beetle Mode ] ]

French PC Term Xon/Xoff handshaking ] Programmable prefix identifiers kmit (dec) as 1st prefix identifier HH Port Rmit (dec) as 2nd prefix identifier [ ] Programmable suffix identifiers Yes amit (dec) as 1st suffix identifier amit dec) as 2nd suffix identifier +

[ [ [ [ [

Hormal flash 500 msec

Fi-Help F3-Enter program mode

Publication 2755-6.14

Page 31

2–20

Configuring your Reader

RS232 Type Options

Description When this option is enabled, the reader transmits Nixdorf code identifiers before each bar code as follows:

Nixdorf ID

Code

Prefix Code

UPC-E d

UPC-A c

EAN-8 g

EAN-13 h

Code 39 b

Codabar a

Code 93 i

I 2 of 5 e

Code 128 j

RTS/CTS handshaking

When this option is enabled, the reader outputs a Request To Send (RTS) signal and waits for a Clear To Send (CTS) signal before any data is transmitted.

RTS/CTS (character)

When this option is enabled, the reader activates and deactivates its RTS signal after each character it transmits.

RTS/CTS (message)

When this option is enabled, the reader activates and deactivates its RTS signal after each message it transmits.

ETX suffix

When this option is enabled, the reader transmits an End of Text after each bar code.

STX prefix

When this option is enabled, the reader transmits a Start of Text before each bar code.

Tab prefix

When this option is enabled, the reader transmits a TAB before each bar code.

Tab suffix

When this option is enabled, the reader transmits a TAB after each bar code.

UPC prefix

When this option is enabled, the reader transmits a prefix before any UPC/EAN bar codes. The prefixes are A (UPC A), E0 (UPC E), F (EAN 13), and FF (EAN 8).

UPC suffix

When this option is enabled, the reader transmits a suffix after any UPC/EAN bar codes. The suffixes are A (UPC A), E0 (UPC E), F (EAN 13), and FF (EAN 8).

Schlumberger/Shell format

When this option is enabled, the reader transmits an XOR’ed check digit of all the data characters at the end of the data stream.

Table continued on the next page.

Publication 2755-6.14

Page 32

Configuring your Reader

RS232 Type Options

2–21

Description

Transmit AIM ID Character

When this option is enabled, the reader transmits special AIM code identifiers before each bar code as follows: Code

AIM Code ID

UPC-E

]Z0

UPC-E with 2–digit suppl.

]Z0

UPC-E with 5–digit suppl.

]Z0

UPC-A

]Z0

UPC-A with 2–digit suppl.

]Z0

UPC-A with 5–digit suppl.

]Z0

EAN-8

]E4

EAN-8 with 2–digit suppl.

]E4

EAN-8 with 5–digit suppl.

]E4

EAN-13

]E0

EAN-13 with 2–digit suppl.

]E0

EAN-13 with 5–digit suppl.

]E0

Code 39

]A0

Code 39 FA

]A4

Code 39 with MOD 43

]A3

Code 39 with MOD 43 plus transmit CD

]A1

Code 39 Full ASCII with MOD 43

]A7

Code 39 Full ASCII with MOD 43 plus transmit CD

]A5

Codabar

]F0

Codabar with start and stop characters

]F1

Code 93

]G0

I 2 of 5

]I0

I 2 of 5 with MOD 10

]I2

I 2 of 5 with MOD 10 and transmit MOD 10

]I1

Code 128

]C0

Table continued on the next page.

Publication 2755-6.14

Page 33

2–22

Configuring your Reader

RS232 Type Options

Publication 2755-6.14

Transmit Sanyo ID Character

Description When this option is enabled, the reader transmits special code identifiers before each bar code as follows: Code

Prefix Code

UPC-A

C

EAN-8

A0

EAN-13

B

Code 39

A

Codabar

M plus 2–digit hexadecimal representation of the character count

Code 93

L plus 2–digit hexadecimal representation of the character count

I 2 of 5

I plus 2–digit hexadecimal representation of the character count

Code 128

K plus 2–digit hexadecimal representation of the character count

SNI Beetle Mode

This feature is not currently supported.

French PC Terminal Emulation

This feature is not currently supported.

Xon/Off handshaking

When this option is enabled, the reader does not transmit after an XOFF is received. Transmission resumes after an XON is received.

Programmable prefix identifiers

When this option is enabled, one or two programmable prefix ID characters can be assigned and added to the scanned data transmission. To assign the character, refer to the options Xmit (Transmit) as 1st prefix identifier or Xmit as 2nd prefix identifier below.

Transmit as 1st or 2nd prefix identifier

When the Programmable prefix identifiers option is enabled, a programmable prefix ID character can be entered in either of these 2 windows. (The decimal equivalent of the ASCII value of the key pressed is then displayed).

Programmable suffix identifiers

When this option is enabled, one or two programmable suffix ID characters can be assigned and added to the scanned data transmission. To assign the character, refer to the options Xmit (Transmit) as 1st suffix identifier or Xmit as 2nd suffix identifier.

Transmit as 1st or 2nd suffix identifier

When the Programmable suffix identifiers option is enabled, a programmable suffix ID character can be entered in either of these 2 windows. (The decimal equivalent of the ASCII value of the key pressed is then displayed).

Page 34

Configuring your Reader

2–23

Note: The following table of 32 ALT characters can be used along with the above RS232 options as programmable prefix or suffix identifiers. For example, if you wanted to use the carriage return character (CR) as a programmable suffix identifier, select the Programmable suffix identifier as an RS232 choice in the OPTIONS pull–down menu. Then hold down the ALT key and type CTRL M. CONTROL CODES for ALT characters Character

Control Code

Character

Control Code

Character

Control Code

Character

Control Code

NULL

CTRL 2

BS

CTRL H

DLE

CTRL P

CAN

CTRL X

SOH

CTRL A

HT

CTRL I

DC1

CTRL Q

EM

CTRL Y

STX

CTRL B

LF

CTRL J

DC2

CTRL R

SUB

CTRL Z

ETX

CTRL C

VT

CTRL K

DC3

CTRL S

ESC

CTRL [

EOT

CTRL D

FF

CTRL L

DC4

CTRL T

FS

CTRL \

ENQ

CTRL E

CR

CTRL M

NAK

CTRL U

GS

CTRL ]

ACK

CTRL F

SO

CTRL N

SYN

CTRL V

RS

CTRL 6

BEL

CTRL G

SI

CTRL O

ETB

CTRL W

US

CTRL _

Wand Emulation Format If Wand Emulation format is selected in the Interface Format menu instead of RS232/422, then Poll Source, High Output and Options boxes display as Wand Emulation specific options.

Wand Type Poll Source

Description When poll source is enabled, the reader does not scan unless a 5–volt signal is seen on the poll source input.

Publication 2755-6.14

Page 35

2–24

Configuring your Reader

Wand Type

Hi/Output

Wand Type Options

Publication 2755-6.14

Description Under this menu, you may program the reader to transmit as one of either Bars high as Code 39. Spaces high as Code 39. Bars high as scanned or Spaces high as scanned. Select the method that matches your host’s requirements.

Description

Extra Transition before Bar Code

If your host requires it, the reader can output an extra transition before each bar code.

50x or 10x narrow element border

This option selects whether the borders on the transmitted bar code will be 10 or 50 times the size of a narrow element. This value is a function of the size of the narrow element selected below.

1.0, 0.5, 0.3, 0.15 ms narrow element

This option selects the size of the narrow element of the transmitted bar code. All other elements in the bar code are a direct function of this value as dictated by the symbology specification.