Page 12

Configuring your Reader Introduction

By selecting “Configuration Screen” from the Main Menu, you are able to access a menu screen from where you can setup custom reader configurations, save configurations to a file, and program your reader. This screen is divided into sections that let you customize your reader configuration. To provide you with easier programming, some of the parameters in the sections automatically change when you choose from the different interface types (RS232 or Wand Emulation). It is recommended that you review all the pop–down menu options, if interface types are changed. To program your reader, you must first put the reader into Program Mode, in order to establish communications between the reader and your host. By pressing F3 while in the Config screen you will enter the Program mode. Or you can enter the Program mode from the Main Menu. Make sure the program is selecting the same Com Port as the one to which you are connected. A successful entry into Program Mode is indicated by: a beep from the reader and the green LED begins to flash. Once you have entered Program Mode, press F5 to download the current configuration screen contents to your reader. Again, you will hear a series of beeps from the reader. Once the reader has completed its processing of the downloaded configuration, you will hear a 3–beep sequence. The green LED then stops flashing, signaling that the reader is ready to scan. To save a configuration to a file, hit F7. You are then prompted for a filename. The filename automatically gets a .TRK extension. Follow normal DOS conventions for naming files. If the file already exists, you will be prompted as to whether you want to overwrite the existing file or not. If you need a printout of all the enabled options from a particular reader, get the reader’s settings and save the configuration to a file. Go to the main screen File List, highlight the appropriate filename, and hit F3. A text file is then created in your working directory listing all the enabled choices in that configuration. The file has the same filename as the one you selected, except for a .set extension. Use a text editor to print the configuration file. Not all options listed within the Configuration Screen are currently supported by the reader. If an option is not supported, this document will specify what that option is.

Publication 2755-6.14

Page 13

2–2

Configuring your Reader

Configuring the Reader

Refer to the following steps to configure the StrataScan Bar Code Readers (Catalog Nos. 2755-LHR-5B, 2755-LHR-3C, 2755-LHR-5C and 2755-LHR-5BX1). 1. Verify that your personal computer has the STRATCFG Programming Software version 4.19 or later loaded onto it. 2. Double–click on the STRATCFG icon or execute the file. 3. Select the Configuration screen from the Main Menu. 4. Review your programming options. If the defaults are acceptable for your application, press F3. If the defaults are not acceptable, change the parameters accordingly. 5. Press ENTER once the settings are correct. The reader is now in Program Mode. The green LED on the reader flashes while the red LED remains lit. A beep is emitted from the reader as well. 6. Press F9 to exit Program Mode. Use the down arrow key to select Exit Mode. 7. Press ENTER. The green LED stops flashing and the laser turns on. 8. Exit StrataSet software. The reader is now configured to read bar codes.

Publication 2755-6.14

Page 14

Configuring your Reader

Configuration Options

2–3

The following sections describe the various StrataScan Configuration options available for the StrataScan Bar Code Readers.

Interface Format This upper left–hand corner of the Configuration Screen gives you the ability to specify the proper communications format, along with all of an interface’s associated options. Specifying options is accomplished for communicating to your host device. And when you change between different interfaces, the Configuration screen changes accordingly. It lets you change all options supported by that interface and protects all those unsupported ones by means of cursor skip–over. The StrataScan line of Readers supports RS232/RS422 and wand emulation. Choose an interface that matches your host system requirements. Select the RS232/RS422 option, if the reader is intended to be used with either RS-232 ± 12V or RS422 serial output. StrataSet software uses this interface to configure your reader. Select Wand Emulation if the reader is used in place of a wand. It provides Wand Emulation of each bar code scanned. Refer to the section about Wand Type interface format for specific information about Wand Emulation options. The No Communication option is reserved for testing purposes. If no communication is selected, then the center of the left–hand side of your Configuration screen is empty.

Publication 2755-6.14

Page 15

2–4

Configuring your Reader

Code Types This portion of the Configuration Screen lets you specify the various bar code types to enable or disable for your application.

Within the Codes Menu Screen, you may enable or disable the codes you want your reader to see or ignore. If a code is enabled, a check mark appears between the two brackets. Then the reader recognizes the enabled type of bar code. The types of codes are: • All UPC/EAN • Code 39 • Full ASCII Code 39 • Code 39 Mod 43 check digit required • Code 93 • Code 128 • Codabar • I2 of 5 • I2 of 5 Mod 10 check digit required • EAN-8 disable, EAN-13 disable, UPC-E disable, UPC-A disable • Paraf

Publication 2755-6.14

Page 16

Configuring your Reader

2–5

Supplementals This box in the Configuration screen gives you the ability to select supplemental support options. Not all supplemental options are currently supported.

Publication 2755-6.14

Page 17

2–6

Configuring your Reader

Supplemental Type

Publication 2755-6.14

Description

2 Digit

When this option is enabled, the reader scans bar codes that have 2-digit supplementals.

5 Digit

When this option is enabled, the reader scans bar codes that have 5-digit supplementals.

977 (2–Digit)

When this option is enabled, the reader requires that a 2-digit supplement be attached to an EAN-13 bar code whenever the bar code begins with 977.

Bookland

When this option is enabled, the reader requires that a 5-digit supplement be attached to an EAN-13 bar code, whenever the bar code begins with 978.

Redundancy 2 Digits

When this option is enabled, the reader scans the bar code plus the 2-digit add-on twice, before accepting the data as valid information.

Redundancy 5 Digits

When this option is enabled, the reader scans the bar code plus the 5-digit add-on twice, before accepting the data as valid information.

Require Supps

When this option is enabled, all UPC/EAN labels that are scanned must have a supplement.

100 ms to find Supps

When this option is enabled, the reader looks for a supplement attached to a bar code, for a maximum of 100 msec.

200 ms to find Supps

When this option is enabled, the reader looks for a supplement attached to a bar code, for a maximum of 200 msec.

Code 128 Coupon Option

When this option is enabled, the reader scans UPC-A, followed by a Code 128 supplement attached.

Code 128 Coupon Conversion

When this option is enabled and when Code 128 coupon option is enabled, a ]C1 is transmitted between the UPC-A bar code and Code 128 supplement.

378/379 lock on supplement

When this option is enabled, all EAN-13 labels are expected to have a 5-digit supplement attached, when the bar code begins with a 378 or 379.

Remote supplement required

When this option is enabled, the host can enable/ disable supplements required, with an ‘R’ (disable requirement) and an ‘N’ (enable requirement).

Page 18

Configuring your Reader

2–7

Miscellaneous This section provides you with the ability to select various miscellaneous functions including beep before/after transmit, communication timeouts, multiple scan buffers, and others.

Publication 2755-6.14

Page 19

2–8

Configuring your Reader

Miscellaneous Type

Beep after transmitting

Beep before transmitting

When this option is enabled, the reader beeps before each bar code is transmitted.

Faster Beep/Same Tone

When this option is enabled, the beeper tone remains the same, but the beep duration is approximately 1/2 normal duration.

Lost Communication Timeout

When this option is enabled, the reader automatically times out after 2 seconds, if unable to complete its data transmission to the host. This is only valid in modes where some type of handshaking is involved.

3 beeps on timeout

When this option is enabled, the reader beeps 3 times when communications have timed out. Lost communication timeout must be enabled for this option to be valid.

razz beep on timeout

When this option is enabled, the reader produces a razzberry tone when communications have timed out. Lost communication timeout must be enabled for this option to be valid.

5 retrys before timeout

When this option is enabled, the reader attempts to re-establish communications 5 times before timing out. Lost communication timeout must be enabled for this option to be valid.

Support ‘D/E’ disable/enable commands

When this option is enabled, the reader suspends scanning when it receives an ASCII ‘D’ from the host device. All timing functions continue. If the reader receives an ASCII ‘d’, scanning is again suspended, plus all buffers are cleared as well. Scanning resumes when the reader receives an ASCII ‘E’ or ‘e’. This feature only works with RS-232 communication.

Support ‘F/L’ Laser off/on commands

When this option is enabled, an ASCII ‘F’ turns off the lasers and ASCII ‘L’ turns on the lasers.

Disable segmented decoding

This option disables UPC Split Code Algorithm. This feature allows for increased scanning accuracy in reading poor quality bar codes, but may slightly reduce the aggressiveness of the reader.

Table continued on the next page.

Publication 2755-6.14

Description When this option is enabled, the reader beeps after each bar code is transmitted. If ACK/NAK is enabled, the reader always beeps after receiving the ACK command.