Page 4

Chapter Objectives

Read this chapter to familiarize yourself with the rest of the manual. You will learn about: • contents of this manual • conventions used in this manual • intended audience • related publications • technical support

Contents of this Manual

The following table describes the contents of this manual. Chapter

Title

Contents

Preface

Describes the purpose, background, and scope of this manual. Also specifies the audience for whom this manual is intended.

1

Software Overview

Provides an introduction for the use of the StrataSet Software.

2

Configuring Your Reader

Provides an overview of the configuration options available for the StrataScan Bar Code Readers.

Publication 2755-6.14

Page 5

P–2

Preface

Conventions Used in this Manual

The following conventions are used throughout this manual. • Bulleted lists such as this one provide information, not procedural steps. • Numbered lists provide sequential steps. • Italic type is used for emphasis. • Text within square brackets in this font represents the keys you press.

Intended Audience

No special knowledge is required to understand this document or use the StrataScan Bar Code Readers (Catalog Nos. 2755-LHR-5B, 2755-LHR-3C, 2755-LHR-5C and 2755-LHR-5BX1).

! Related Publications

ATTENTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

The following table lists an additional publication related to the StrataScan Bar Code Readers. Publication Number

Technical Support Services

Title

2755-6.13

StrataScan Bar Code Readers User Manual

2755-921

Bar Code Basics

If you have any questions about the StrataScan Bar Code Reader, please consult this manual first. If you can’t find the answer, contact Rockwell Automation International Support: Rockwell International Technical Support 6680 Beta Drive Mayfield Village, Ohio 36849 Contact your Allen-Bradley office or call (440) 646–6800 for hardware questions, (440) 646–7800 for software questions.

Publication 2755-6.14

Page 6

Software Overview Introduction

The StrataScan bar Code Readers are all programmable through Allen-Bradley’s DOS–based software entitled StrataSet. With StrataSet, you have the ability to program your reader or upload reader configurations without the need to scan any bar codes. Once the reader is connected by the proper RS-232 cable to an IBMcompatible PC XT, AT, or PS/2, you can choose reader configuration options from StrataScan’s menus. After the desired parameters are chosen, the configuration settings can be downloaded from the PC to the reader. StrataSet also allows you to save configuration screens for later use and allows you to upload and save existing reader setups. With this method, programming a number of readers with the same parameters is much easier and eliminates the need to establish configurations by scanning a list of bar codes. You will need the following items to use StrataSet: • StrataSet diskette • Windows 95 or Windows NT, MS-DOS, IBM PC XT, AT or PS/2 compatible (386 or greater is recommended) • Available RS-232C serial port • One of the previously mentioned Allen-Bradley readers with appropriate RS-232 cable setup (2755-LHC-11 or -12).

Starting the StrataSet Program

To familiarize yourself with the StrataSet, access the StrataSet program and review the menus discussed on the following pages before entering Program Mode. Before using StrataSet, make a backup copy of the diskette. You can run the StrataSet file from the floppy disk provided or you can copy the file to your hard disk. For faster processing time and greater free disk space, it is recommended that you copy the STRATCFG.EXE file to your hard disk, under a specified directory (e.g., C:\STRATCFG). To avoid potential problems, do not power up the reader until the communication cable is secured to the host.

Publication 2755-6.14

Page 7

1–2

Variable Content TTL:Chap Is Linked To HD:Running

To start the Stratascan software: 1. Turn off power to PC and the reader. 2. Connect the communication cable provided, between the reader and the RS-232C serial port (COM 1 or COM 2) located on the PC. 3. Turn on the PC and the reader. 4. Change to the subdirectory where the STRATCFG.EXE file is stored. 5. At the DOS prompt, type STRATCFG and press ENTER. Note: If you are using a monochrome monitor and are having difficulty seeing the highlighted menu choices, quit and restart the program by typing STRATCFG/B at the DOS prompt. If you are still experiencing difficulty seeing the highlighted menu choice, look for the blinking cursor.

Using StrataSet Menus

All the choices needed to configure your reader are available through pop-up windows that appear when ENTER is pressed at any of the menu headings. At the Main Menu, highlight Configuration Screen (or press 1)and press ENTER to view the Configuration Screen. Use the following method to view a pop-up menu: 1. Use the TAB, up, down, left, or arrow keys to move the highlight to the desired menu choice. 2. Once the menu choice is highlighted, press ENTER. A pop-up menu then appears with various option choices. Use the following method to select item(s) from within the pop-up menu: 1. Use the PAGE UP, PAGE DOWN, up arrow or down arrow keys to position the cursor on the desired option. 2. If the menu is a multiple choice menu, such as the Interface menu, press ENTER to select the desired option. If the menu contains brackets [ ], then you may either select or deselect the particular option. Press the SPACE BAR to toggle the selection and then hit ENTER when all selections are complete.

Publication 2755-6.14

Page 8

Variable Content TTL:Chap Is Linked To HD:Running

Keyboard Commands

1–3

The following keys perform a given function as described below. Function Key

Description

ENTER

To display a list of options for a given vertical field within the Configuration Screen or to select a Main Menu screen choice, position the cursor on the desired field and press ENTER. ENTER will also allow you exit from a pop-up window menu.

SPACE BAR

Within the pop-up window menus, an option may have a left and right bracket before the menu choice. These options can either be enabled or disabled. To enable or disable an option, position the cursor on the menu choice and press the SPACE BAR key. When a check mark is within the brackets, the option is enabled.

ESC Exit

Escape will also allow you to escape out of most situations.

F1 Help

For a brief description of the function of a vertical menu, position the cursor on the desired field and press F1. To exit help, press ESC. If you are within the Configuration Screen, hitting F3 puts the reader into Program Mode.

F3 Enter Program Mode or Create Choice File

If you are at the Main Menu screen, F3 allows you to generate a text file, listing all options a particular configuration file has enabled. For example, if you want a listing of all the enabled settings your reader has, refer to Program Mode, Getting Scanner Settings and Saving Settings to File. Select the filename from the file list, hit F3 and a file listing all enabled choices within that file is created in your working directory. This file will share the same filename, except that it will have a .set extension.

F5 Program Scanner

After the desired parameters are selected in the Configuration Screen, press F5 to program the reader to those same settings. (This assumes you have already entered Program Mode successfully.)

F7 Save Parameters

To save the various parameters selected in the Configuration Screen, press F7. The settings are then saved in a file for future reference and programming. When assigning a filename, use the proper DOS convention. StrataSet automatically saves the file with the extension .TRK. The file is saved to the same drive and directory from which StrataSet is being run.

F9 Return to Main Menu or Delete File

If you select File List from the Main Menu, you are able to delete files by hitting F9. You will be prompted to verify your selection (ESC terminates the process). If you are within the Configuration Screen, pressing F9 returns you to the Main Menu.

Publication 2755-6.14

Page 9

1–4

Variable Content TTL:Chap Is Linked To HD:Running

StrataSet Main Menu

The following sections describe the menu choices available from the StrataSet Main Menu.

Configuration Screen Press 1 to activate this option, or move the cursor to this location and hit ENTER. By choosing this option, you will enter the Configuration screen, where custom reader configurations can be created.

Publication 2755-6.14

Page 10

Variable Content TTL:Chap Is Linked To HD:Running

1–5

This screen also allows you to save and/or download configurations to the reader. The settings first displayed are the StrataSet RS232 default settings, not the reader settings. With the methods described under “Using the StrataSet Menus” you are able to move around this screen and change options. After configuring the screen for your particular application, you can save the screen to a file, download the settings to the reader, or both.

Get Scanner Settings Press 2 to activate this option, or move the cursor to this location and hit ENTER. This option lets you view the reader’s configuration by uploading the information from the reader through your PC’s COM port. You must first enter Program Mode to initialize communications between the PC and the reader. (See Enter Program Mode for more information). Once you have entered Program Mode and selected this option, the configuration screen displays the reader’s programmed parameters. The reader beeps once if it has successfully entered Program Mode. The reader beeps again (either 3 times for the 2755-LHR-3C or 5 times for the 2755-LHR-5B, 5C and 5BX1) when it has transmitted its configuration. You must exit Program Mode after getting the reader’s configuration, before you can resume normal scanning. (See Exit Program Mode for more information).

File List Press 3 to activate this option or move the cursor to this location and hit ENTER. By choosing this option, a list of .TRK files residing in the current directory is displayed. After highlighting a filename, you can hit ENTER and the file is transferred to the Configuration screen. You can delete the file by pressing F9, or hit F3 to generate a .SET file listing all enabled reader options in that file.

Select Com Port Press 4 to activate this option, or move the cursor to this location and hit ENTER. This option allows you to select either Com1 or Com2. You may be prompted to select a Com Port during various steps of the programming or uploading sequence.

Enter Program Mode Press 5 to activate this option, or move the cursor to this location and hit ENTER. This function prepares the reader for communication interfacing. One long beep from the reader indicates a successful entry into program mode.

Publication 2755-6.14

Page 11

1–6

Variable Content TTL:Chap Is Linked To HD:Running

Exit Program Mode Press 6 to activate this option or move the cursor to this location and hit ENTER. This option causes the reader to exit programming mode. Three beeps from the reader indicates a successful exit from Program Mode. Note that if you program the reader from the Configuration screen, the program exits Program Mode if you press F5. Once you exit Program Mode, you are then able to resume normal scanning.

Software Compatibility Press 7 to activate this option, or move the cursor to this location and hit ENTER. This option returns the firmware version installed in the reader and specifies if it is compatible with existing StrataScan software. Hitting any key returns you to the current screen. To perform this test, it is not necessary to enter Program Mode first.

Exit to DOS Press 8 to activate this option, or move the cursor to this location and press ENTER. This option closes the program and returns you to the DOS prompt or Windows.