Page 71

Chapter

A–B

7

Network Design Networks of 32 Workstations or Less

Designing a network to connect fewer than 32 workstations is fairly straight forward: select the best place for the Master Workstation to be, and then run one single multi-dropped twisted pair cable through each workstation location. The “Master” workstation is the workstation which communicates to the host. A simple network Configuration follows: Figure 7.1 Simple Network Configuration Host W M

M Workstation Master

W - W - W - W - W - W - W - W - W Indicates RS-232 Indicates RSS-485 backbone

No more than 32 workstations can be connected to the same network cable. If more than 32 workstations are required, see the next section. The last step of this network is to compare the actual cable distances between each workstation with the distances described in Chapter 2. Note: All references to RS-232 should be understood to mean RS-422 if the workstation’s COM1 port was ordered as RS-422.

Network Installation of More than 32 Workstations

Installing a large network of workstations involves connecting together smaller networks. Up to 31 smaller sub-networks may be attached to form a large network. Each sub-network, in turn, may contain up to 32 workstations. The network which connects all of the sub-networks is called the ‘backbone’ network. Each sub-network is referred to as a ‘tributary’ network. A maximum of 1024 workstations may be connected in this fashion. There are instances where a tributary network can improve performance even when fewer than 32 workstations are on the network. The workstation which is attached to the host is configured to as the “Master”. Each workstation on the backbone network that connects to a tributary network is configured as “Concentrator”. The workstation on the tributary which attaches to the Concentrator is configured as a “Submaster”.

7–1

Page 72

Chapter 7 Network Design

Network Installation of More than 32 Workstations (cont’d)

All of the workstations, including Masters, Concentrators and Submasters, are standard workstations which have been configured for their individual roles in the network. A configuration parameter is changed to allow any workstation to adopt a new role in the network. Each workstation is capable of operating in both a data collection and data communications mode. An example of a large network configuration follows: Figure 7.2 Large Network Configuration

Host

Key: W S C M

W | W W | | W W | | S S | | M - W - C - W - C - W - C - W - W - C - C - W | | | S S S | | | W W W | | | W W W | | W W | W

Workstation Submaster Concentrator Master

Indicates RS-232 connect Indicates RS-485 backbone Indicates a tributary

A workstation which is being used as a Master, Concentrator or Submaster can perform data collection functions even while serving in the communications network. Note: All references to RS-232 should be understood to mean RS-422 if the workstation’s COM1 port was ordered as RS-422.

7–2

Page 73

Chapter 7 Network Design

Fault-Tolerant Networks

When installing large networks, you should consider redundant communication links in order to protect against workstation failures. This involves establishing certain workstations as “Alternate Masters” and certain workstations as “Alternate Submasters”. Configuring a large network with Alternate Masters will allow the Alternate workstation to take over communication operations if the designated Master becomes inoperable or is removed from the network. An Alternate Host provides full redundancy for collection in the event of a host failure. A large network configuration with Alternate Masters could look like the following: Figure 7.3 Large Network Configuration with Alternate Masters

Host Host

Key: W S C M A

W | W W | | W W | | S S | | M - A - C - C - W - C - W - C - W - W - C - C | | | S S S | | | A W W | | | W W W | W Workstation Submaster Concentrator Master Alternate

Indicates RS-232 connect Indicates RS-485 backbone Indicates a tributary

Note: All references to RS-232 should be understood to mean RS-422 if the workstation’s COM1 port was ordered as RS-422.

7–3

Page 74

Chapter 7 Network Design

Extending Networks Over Phone Lines

It is possible to configure a network which spans multiple buildings, outposts or sub-stations located at remote sites. Switched (dial-up) or leased telephone lines (also referred to as ‘Common Carrier’) can be used with asynchronous modems to provide communications for such a network. Asynchronous short-haul modems may be used to extend the normal RS-232 communication distance from 100 feet to as much as several miles. The only modem recommended for networks over dial-up telephone lines is a 212-A compatible modem.① To use modems for communications between a Concentrator and Submaster, the workstations must have the RS-232 communications port and a modem cable connected for TXD, RXD, RTS, CTS, DSR, DTR and GROUND (see Chapter 2). The COMM BAUD RATE parameter must be changed from 9600 baud to whatever baud rate is correct for your modem. As soon as the modems establish communications between themselves the remote system will be ready for use. A Concentrator which has not yet been connected via modem to the Submaster will display: mm–nn

READY/ONLINE [C] ?

When the Submaster does respond, the ? is removed to display: mm–nn

READY/ONLINE [C]

① A “Hayes-compatible” modem is a good choice.

7–4

Page 75

Chapter 7 Network Design

Extending Networks Over Phone Lines (cont’d)

The following is an example of a network extending across a Common Carrier.

Figure 7.4 Extending Network Across Common Ca;rrier Backbone Network W | M | W | W | C | W | W

Tributary Network

W | W | W | S | W

HOST modem modem Telco

Key: W S C M

Workstation Submaster Concentrator Master

Indicates RS-232 connect Indicates RS-485 backbone

The extension of a network across telephone lines consists of placing a modem on one side of the line to connect with the Concentrator, and placing the other modem on the other side to connect with the Submaster.

Figure 7.5 Extending Network Across Common Ca;rrier Backbone Network W | W | G | W

HOST COM2

Tributary Network modem COM1

Key: W S C M G

Workstation Submaster Concentrator Master Gateway modem Telco

W | S | W | W

Indicates RS-232 connect Indicates RS-485 backbone

7–5