Page 173

CHAPTER 12 SYMBOLOGIES Introduction You can program the scanner to perform various functions, or activate different features. This chapter describes symbology features and provides programming bar codes for selecting these features. The scanner ships with the settings shown in Table 12-1 on page 12-2 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary.

Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, see Default Parameters on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates default

*Enable Parameter

Feature/option

Page 174

12 - 2

DS2208 Digital Scanner Product Reference Guide

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 12-18. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Lengths for D 2 of 5, require scanning several bar codes. See the parameter descriptions for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Symbology Parameter Defaults Table 12-1 lists defaults for all symbology parameters. Change these values in one of two ways: • Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall the default parameter values, see Default Parameters on page 5-5. • Configure the scanner using the 123Scan2 configuration program. See Chapter 12, Symbologies. NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.

Table 12-1

Symbology Parameter Defaults Parameter

Parameter Number 1

SSI Number 2

Default

Enable/Disable All Code Types

Page Number 12-8

1D Symbologies UPC/EAN/JAN UPC-A

1

01h

Enable

12-8

UPC-E

2

02h

Enable

12-9

UPC-E1

12

0Ch

Disable

12-9

EAN-8/JAN 8

4

04h

Enable

12-10

EAN-13/JAN 13

3

03h

Enable

12-10

Bookland EAN

83

53h

Disable

12-11

Bookland ISBN Format

576

F1h 40h

ISBN-10

12-12

ISSN EAN

617

F1h 69h

Disable

12-12

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 175

Symbologies

Table 12-1

12 - 3

Symbology Parameter Defaults (Continued) Parameter

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

Parameter Number 1

SSI Number 2

16

10h

User-Programmable Supplementals

Default

Page Number

Ignore

12-13

000

12-16

Supplemental 1:

579

F1h 43h

Supplemental 2:

580

F1h 44h

UPC/EAN/JAN Supplemental Redundancy

80

50h

10

12-16

Decode UPC/EAN/JAN Supplemental AIM ID

672

F1h A0h

Combined

12-17

Transmit UPC-A Check Digit

40

28h

Enable

12-18

Transmit UPC-E Check Digit

41

29h

Enable

12-18

Transmit UPC-E1 Check Digit

42

2Ah

Enable

12-19

UPC-A Preamble

34

22h

System Character

12-20

UPC-E Preamble

35

23h

System Character

12-21

UPC-E1 Preamble

36

24h

System Character

12-22

Convert UPC-E to A

37

25h

Disable

12-23

Convert UPC-E1 to A

38

26h

Disable

12-23

EAN/JAN Zero Extend

39

27h

Disable

12-24

UCC Coupon Extended Code

85

55h

Disable

12-24

Coupon Report

730

F1h DAh

New Coupon Format

12-25

UPC Reduced Quiet Zone

1289

F8h 05h 09h

Disable

12-25

Code 128

8

08h

Enable

12-26

Set Lengths for Code 128

209, 210

D1h, D2h

1 - 55

12-26

GS1-128 (formerly UCC/EAN-128)

14

0Eh

Enable

12-27

ISBT 128

84

54h

Disable

12-28

ISBT Concatenation

577

F1h 41h

Disable

12-29

Check ISBT Table

578

F1h 42h

Enable

12-30

ISBT Concatenation Redundancy

223

DFh

10

12-30

Code 128 <FNC4>

1254

F8h 04h E6h

Honor

12-31

Code 128

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 176

12 - 4

DS2208 Digital Scanner Product Reference Guide

Table 12-1

Symbology Parameter Defaults (Continued) Parameter Number 1

SSI Number 2

Code 128 Security Level

751

F1h EFh

Security Level 1

12-31

Code 128 Reduced Quiet Zone

1208

F8h 04h B8h

Disable

12-32

Code 39

0

00h

Enable

12-33

Trioptic Code 39

13

0Dh

Disable

12-33

Convert Code 39 to Code 32 (Italian Pharmacy Code)

86

56h

Disable

12-34

Code 32 Prefix

231

E7h

Disable

12-34

Set Lengths for Code 39

18, 19

12h, 13h

1 - 55

12-35

Code 39 Check Digit Verification

48

30h

Disable

12-36

Transmit Code 39 Check Digit

43

2Bh

Disable

12-37

Code 39 Full ASCII Conversion

17

11h

Disable

12-37

Code 39 Security Level

750

F1h EEh

Security Level 1

12-38

Code 39 Reduced Quiet Zone

1209

F8h 04h B9h

Disable

12-40

Code 93

9

09h

Enable

12-40

Set Lengths for Code 93

26, 27

1Ah, 1Bh

1 - 55

12-41

Code 11

10

0Ah

Disable

12-43

Set Lengths for Code 11

28, 29

1Ch, 1Dh

4 to 55

12-43

Code 11 Check Digit Verification

52

34h

Disable

12-45

Transmit Code 11 Check Digit(s)

47

2Fh

Disable

12-46

Interleaved 2 of 5 (ITF)

6

06h

Enable

12-46

Set Lengths for I 2 of 5

22, 23

16h, 17h

6 to 55

12-47

I 2 of 5 Check Digit Verification

49

31h

Disable

12-49

Transmit I 2 of 5 Check Digit

44

2Ch

Disable

12-50

Convert I 2 of 5 to EAN 13

82

52h

Disable

12-50

Febraban

1750

F8h 06h D6h

Disable

12-51

Parameter

Default

Page Number

Code 39

Code 93

Code 11

Interleaved 2 of 5 (ITF)

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 177

Symbologies

Table 12-1

12 - 5

Symbology Parameter Defaults (Continued) Parameter Number 1

SSI Number 2

I 2 of 5 Security Level

1121

F8h 04h 61h

Security Level 1

12-52

I 2 of 5 Reduced Quiet Zone

1210

F8h 04h BAh

Disable

12-53

Discrete 2 of 5

5

05h

Disable

12-53

Set Lengths for D 2 of 5

20, 21

14h 15h

1 to 55

12-54

Codabar

7

07h

Enable

12-56

Set Lengths for Codabar

24, 25

18h, 19h

4 to 55

12-56

CLSI Editing

54

36h

Disable

12-58

NOTIS Editing

55

37h

Disable

12-58

Codabar Upper or Lower Case Start/ Stop Characters Detection

855

F2h 57h

Upper Case

12-59

MSI

11

0Bh

Disable

12-59

Set Lengths for MSI

30, 31

1Eh, 1Fh

4 to 55

12-60

MSI Check Digits

50

32h

One

12-62

Transmit MSI Check Digit

46

2Eh

Disable

12-62

MSI Check Digit Algorithm

51

33h

Mod 10/Mod 10

12-63

MSI Reduced Quiet Zone

1392

F8h 05h 70h

Disable

12-63

408

F0h 98h

Disable

12-64

Matrix 2 of 5

618

F1h 6Ah

Disable

12-64

Matrix 2 of 5 Lengths

619 620

F1h 6Bh F1h 6Ch

4 to 55

12-65

Matrix 2 of 5 Check Digit

622

F1h 6Eh

Disable

12-67

Transmit Matrix 2 of 5 Check Digit

623

F1h 6Fh

Disable

12-67

Parameter

Default

Page Number

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 178

12 - 6

DS2208 Digital Scanner Product Reference Guide

Table 12-1

Symbology Parameter Defaults (Continued) Parameter Number 1

SSI Number 2

Korean 3 of 5

581

F1h 45h

Disable

12-68

Inverse 1D

586

F1h 4Ah

Regular

12-69

GS1 DataBar Omnidirectional

338

F0h 52h

Enable

12-70

GS1 DataBar Limited

339

F0h 53h

Enable

12-70

GS1 DataBar Expanded

340

F0h 54h

Enable

12-71

Convert GS1 DataBar to UPC/EAN/JAN

397

F0h 8Dh

Disable

12-71

GS1 DataBar Limited Margin Check

728

F1h D8h

Level 3

12-72

GS1 DataBar Security Level

1706

F8h 06h AAh

Level 1

12-73

Redundancy Level

78

4Eh

1

12-74

Security Level

77

4Dh

1

12-76

1D Quiet Zone Level

1288

F8h 05h 08h

1

12-77

Intercharacter Gap Size

381

F0h 7Dh

Normal

12-78

Composite CC-C

341

F0h 55h

Disable

12-78

Composite CC-A/B

342

F0h 56h

Disable

12-79

Composite TLC-39

371

F0h 73h

Disable

12-79

Composite Inverse

1113

F8h 04h 59h

Regular Only

12-80

UPC Composite Mode

344

F0h 58h

UPC Never Linked

12-81

Composite Beep Mode

398

F0h 8Eh

Beep As Each Code Type is Decoded

12-82

GS1-128 Emulation Mode for UCC/EAN Composite Codes

427

F0h ABh

Disable

12-82

PDF417

15

0Fh

Enable

12-83

MicroPDF417

227

E3h

Disable

12-83

Code 128 Emulation

123

7Bh

Disable

12-84

Parameter

Default

Page Number

Korean 3 of 5

GS1 DataBar

Symbology-Specific Security Features

Composite Codes

2D Symbologies

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 179

Symbologies

Table 12-1

12 - 7

Symbology Parameter Defaults (Continued) Parameter Number 1

SSI Number 2

Data Matrix

292

F0h 24h

Enable

12-85

GS1 Data Matrix

1336

F8h 05h 38h

Disable

12-85

Data Matrix Inverse

588

F1h 4Ch

Inverse Autodetect

12-86

Decode Data Matrix Mirror Images

537

F1h 19h

Auto

12-87

Maxicode

294

F0h 26h

Disable

12-88

QR Code

293

F0h 25h

Enable

12-88

GS1 QR

1343

F8h 05h 3Fh

Disable

12-89

MicroQR

573

F1h 3Dh

Enable

12-89

Aztec

574

F1h 3Eh

Enable

12-90

Aztec Inverse

589

F1h 4Dh

Inverse Autodetect

12-91

Han Xin

1167

F8h 04h 8Fh

Disable

12-92

Han Xin Inverse

1168

F8h 04h 90h

Regular

12-92

Grid Matrix

1718

F8 06 B6

Disable

12-93

Grid Matrix Inverse

1719

F8 06 B7

Regular Only

12-93

Grid Matrix Mirror

1736

F8 06 C8

Regular Only

12-94

US Postnet

89

59h

Disable

12-96

US Planet

90

5Ah

Disable

12-96

Transmit US Postal Check Digit

95

5Fh

Enable

12-97

UK Postal

91

5Bh

Disable

12-97

Transmit UK Postal Check Digit

96

60h

Enable

12-98

Japan Postal

290

F0h 22h

Disable

12-98

Australia Post

291

F0h 23h

Disable

12-99

Australia Post Format

718

F1h CEh

Autodiscriminate

12-100

Netherlands KIX Code

326

F0h 46h

Disable

12-101

USPS 4CB/One Code/Intelligent Mail

592

F1h 50h

Disable

12-101

UPU FICS Postal

611

F1h 63h

Disable

12-102

Mailmark

1337

F8h 05h 39h

Disable

12-102

Parameter

Default

Page Number

Postal Codes

1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.

Page 180

12 - 8

DS2208 Digital Scanner Product Reference Guide

Enable/Disable All Code Types Scan the Disable All Code Types bar code to disable all symbologies. This is useful when enabling only a few code types. Scan Enable All Code Types to enable all symbologies. This is useful if you need to disable only a few code types.

Disable All Code Types

Enable All Code Types

UPC/EAN/JAN UPC-A Parameter # 1 SSI # 01h Scan one of the following bar codes to enable or disable UPC-A.

*Enable UPC-A (1)

Disable UPC-A (0)

Page 181

Symbologies

UPC-E Parameter # 2 SSI # 02h Scan one of the following bar codes to enable or disable UPC-E.

*Enable UPC-E (1)

Disable UPC-E (0)

UPC-E1 Parameter # 12 SSI # 0Ch Scan one of the following bar codes to enable or disable UPC-E1. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1 (1)

*Disable UPC-E1 (0)

12 - 9

Page 182

12 - 10

DS2208 Digital Scanner Product Reference Guide

EAN-8/JAN-8 Parameter # 4 SSI # 04h Scan one of the following bar codes to enable or disable EAN-8/JAN-8.

*Enable EAN-8/JAN-8 (1)

Disable EAN-8/JAN-8 (0)

EAN-13/JAN-13 Parameter # 3 SSI # 03h Scan one of the following bar codes to enable or disable EAN-13/JAN-13.

*Enable EAN-13/JAN-13 (1)