Page 173
CHAPTER 12 SYMBOLOGIES Introduction You can program the scanner to perform various functions, or activate different features. This chapter describes symbology features and provides programming bar codes for selecting these features. The scanner ships with the settings shown in Table 12-1 on page 12-2 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary.
Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.
If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, see Default Parameters on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates default
*Enable Parameter
Feature/option
Page 174
12 - 2
DS2208 Digital Scanner Product Reference Guide
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 12-18. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Lengths for D 2 of 5, require scanning several bar codes. See the parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults Table 12-1 lists defaults for all symbology parameters. Change these values in one of two ways: • Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall the default parameter values, see Default Parameters on page 5-5. • Configure the scanner using the 123Scan2 configuration program. See Chapter 12, Symbologies. NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
Table 12-1
Symbology Parameter Defaults Parameter
Parameter Number 1
SSI Number 2
Default
Enable/Disable All Code Types
Page Number 12-8
1D Symbologies UPC/EAN/JAN UPC-A
1
01h
Enable
12-8
UPC-E
2
02h
Enable
12-9
UPC-E1
12
0Ch
Disable
12-9
EAN-8/JAN 8
4
04h
Enable
12-10
EAN-13/JAN 13
3
03h
Enable
12-10
Bookland EAN
83
53h
Disable
12-11
Bookland ISBN Format
576
F1h 40h
ISBN-10
12-12
ISSN EAN
617
F1h 69h
Disable
12-12
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 175
Symbologies
Table 12-1
12 - 3
Symbology Parameter Defaults (Continued) Parameter
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
Parameter Number 1
SSI Number 2
16
10h
User-Programmable Supplementals
Default
Page Number
Ignore
12-13
000
12-16
Supplemental 1:
579
F1h 43h
Supplemental 2:
580
F1h 44h
UPC/EAN/JAN Supplemental Redundancy
80
50h
10
12-16
Decode UPC/EAN/JAN Supplemental AIM ID
672
F1h A0h
Combined
12-17
Transmit UPC-A Check Digit
40
28h
Enable
12-18
Transmit UPC-E Check Digit
41
29h
Enable
12-18
Transmit UPC-E1 Check Digit
42
2Ah
Enable
12-19
UPC-A Preamble
34
22h
System Character
12-20
UPC-E Preamble
35
23h
System Character
12-21
UPC-E1 Preamble
36
24h
System Character
12-22
Convert UPC-E to A
37
25h
Disable
12-23
Convert UPC-E1 to A
38
26h
Disable
12-23
EAN/JAN Zero Extend
39
27h
Disable
12-24
UCC Coupon Extended Code
85
55h
Disable
12-24
Coupon Report
730
F1h DAh
New Coupon Format
12-25
UPC Reduced Quiet Zone
1289
F8h 05h 09h
Disable
12-25
Code 128
8
08h
Enable
12-26
Set Lengths for Code 128
209, 210
D1h, D2h
1 - 55
12-26
GS1-128 (formerly UCC/EAN-128)
14
0Eh
Enable
12-27
ISBT 128
84
54h
Disable
12-28
ISBT Concatenation
577
F1h 41h
Disable
12-29
Check ISBT Table
578
F1h 42h
Enable
12-30
ISBT Concatenation Redundancy
223
DFh
10
12-30
Code 128 <FNC4>
1254
F8h 04h E6h
Honor
12-31
Code 128
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 176
12 - 4
DS2208 Digital Scanner Product Reference Guide
Table 12-1
Symbology Parameter Defaults (Continued) Parameter Number 1
SSI Number 2
Code 128 Security Level
751
F1h EFh
Security Level 1
12-31
Code 128 Reduced Quiet Zone
1208
F8h 04h B8h
Disable
12-32
Code 39
0
00h
Enable
12-33
Trioptic Code 39
13
0Dh
Disable
12-33
Convert Code 39 to Code 32 (Italian Pharmacy Code)
86
56h
Disable
12-34
Code 32 Prefix
231
E7h
Disable
12-34
Set Lengths for Code 39
18, 19
12h, 13h
1 - 55
12-35
Code 39 Check Digit Verification
48
30h
Disable
12-36
Transmit Code 39 Check Digit
43
2Bh
Disable
12-37
Code 39 Full ASCII Conversion
17
11h
Disable
12-37
Code 39 Security Level
750
F1h EEh
Security Level 1
12-38
Code 39 Reduced Quiet Zone
1209
F8h 04h B9h
Disable
12-40
Code 93
9
09h
Enable
12-40
Set Lengths for Code 93
26, 27
1Ah, 1Bh
1 - 55
12-41
Code 11
10
0Ah
Disable
12-43
Set Lengths for Code 11
28, 29
1Ch, 1Dh
4 to 55
12-43
Code 11 Check Digit Verification
52
34h
Disable
12-45
Transmit Code 11 Check Digit(s)
47
2Fh
Disable
12-46
Interleaved 2 of 5 (ITF)
6
06h
Enable
12-46
Set Lengths for I 2 of 5
22, 23
16h, 17h
6 to 55
12-47
I 2 of 5 Check Digit Verification
49
31h
Disable
12-49
Transmit I 2 of 5 Check Digit
44
2Ch
Disable
12-50
Convert I 2 of 5 to EAN 13
82
52h
Disable
12-50
Febraban
1750
F8h 06h D6h
Disable
12-51
Parameter
Default
Page Number
Code 39
Code 93
Code 11
Interleaved 2 of 5 (ITF)
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 177
Symbologies
Table 12-1
12 - 5
Symbology Parameter Defaults (Continued) Parameter Number 1
SSI Number 2
I 2 of 5 Security Level
1121
F8h 04h 61h
Security Level 1
12-52
I 2 of 5 Reduced Quiet Zone
1210
F8h 04h BAh
Disable
12-53
Discrete 2 of 5
5
05h
Disable
12-53
Set Lengths for D 2 of 5
20, 21
14h 15h
1 to 55
12-54
Codabar
7
07h
Enable
12-56
Set Lengths for Codabar
24, 25
18h, 19h
4 to 55
12-56
CLSI Editing
54
36h
Disable
12-58
NOTIS Editing
55
37h
Disable
12-58
Codabar Upper or Lower Case Start/ Stop Characters Detection
855
F2h 57h
Upper Case
12-59
MSI
11
0Bh
Disable
12-59
Set Lengths for MSI
30, 31
1Eh, 1Fh
4 to 55
12-60
MSI Check Digits
50
32h
One
12-62
Transmit MSI Check Digit
46
2Eh
Disable
12-62
MSI Check Digit Algorithm
51
33h
Mod 10/Mod 10
12-63
MSI Reduced Quiet Zone
1392
F8h 05h 70h
Disable
12-63
408
F0h 98h
Disable
12-64
Matrix 2 of 5
618
F1h 6Ah
Disable
12-64
Matrix 2 of 5 Lengths
619 620
F1h 6Bh F1h 6Ch
4 to 55
12-65
Matrix 2 of 5 Check Digit
622
F1h 6Eh
Disable
12-67
Transmit Matrix 2 of 5 Check Digit
623
F1h 6Fh
Disable
12-67
Parameter
Default
Page Number
Discrete 2 of 5 (DTF)
Codabar (NW - 7)
MSI
Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 178
12 - 6
DS2208 Digital Scanner Product Reference Guide
Table 12-1
Symbology Parameter Defaults (Continued) Parameter Number 1
SSI Number 2
Korean 3 of 5
581
F1h 45h
Disable
12-68
Inverse 1D
586
F1h 4Ah
Regular
12-69
GS1 DataBar Omnidirectional
338
F0h 52h
Enable
12-70
GS1 DataBar Limited
339
F0h 53h
Enable
12-70
GS1 DataBar Expanded
340
F0h 54h
Enable
12-71
Convert GS1 DataBar to UPC/EAN/JAN
397
F0h 8Dh
Disable
12-71
GS1 DataBar Limited Margin Check
728
F1h D8h
Level 3
12-72
GS1 DataBar Security Level
1706
F8h 06h AAh
Level 1
12-73
Redundancy Level
78
4Eh
1
12-74
Security Level
77
4Dh
1
12-76
1D Quiet Zone Level
1288
F8h 05h 08h
1
12-77
Intercharacter Gap Size
381
F0h 7Dh
Normal
12-78
Composite CC-C
341
F0h 55h
Disable
12-78
Composite CC-A/B
342
F0h 56h
Disable
12-79
Composite TLC-39
371
F0h 73h
Disable
12-79
Composite Inverse
1113
F8h 04h 59h
Regular Only
12-80
UPC Composite Mode
344
F0h 58h
UPC Never Linked
12-81
Composite Beep Mode
398
F0h 8Eh
Beep As Each Code Type is Decoded
12-82
GS1-128 Emulation Mode for UCC/EAN Composite Codes
427
F0h ABh
Disable
12-82
PDF417
15
0Fh
Enable
12-83
MicroPDF417
227
E3h
Disable
12-83
Code 128 Emulation
123
7Bh
Disable
12-84
Parameter
Default
Page Number
Korean 3 of 5
GS1 DataBar
Symbology-Specific Security Features
Composite Codes
2D Symbologies
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 179
Symbologies
Table 12-1
12 - 7
Symbology Parameter Defaults (Continued) Parameter Number 1
SSI Number 2
Data Matrix
292
F0h 24h
Enable
12-85
GS1 Data Matrix
1336
F8h 05h 38h
Disable
12-85
Data Matrix Inverse
588
F1h 4Ch
Inverse Autodetect
12-86
Decode Data Matrix Mirror Images
537
F1h 19h
Auto
12-87
Maxicode
294
F0h 26h
Disable
12-88
QR Code
293
F0h 25h
Enable
12-88
GS1 QR
1343
F8h 05h 3Fh
Disable
12-89
MicroQR
573
F1h 3Dh
Enable
12-89
Aztec
574
F1h 3Eh
Enable
12-90
Aztec Inverse
589
F1h 4Dh
Inverse Autodetect
12-91
Han Xin
1167
F8h 04h 8Fh
Disable
12-92
Han Xin Inverse
1168
F8h 04h 90h
Regular
12-92
Grid Matrix
1718
F8 06 B6
Disable
12-93
Grid Matrix Inverse
1719
F8 06 B7
Regular Only
12-93
Grid Matrix Mirror
1736
F8 06 C8
Regular Only
12-94
US Postnet
89
59h
Disable
12-96
US Planet
90
5Ah
Disable
12-96
Transmit US Postal Check Digit
95
5Fh
Enable
12-97
UK Postal
91
5Bh
Disable
12-97
Transmit UK Postal Check Digit
96
60h
Enable
12-98
Japan Postal
290
F0h 22h
Disable
12-98
Australia Post
291
F0h 23h
Disable
12-99
Australia Post Format
718
F1h CEh
Autodiscriminate
12-100
Netherlands KIX Code
326
F0h 46h
Disable
12-101
USPS 4CB/One Code/Intelligent Mail
592
F1h 50h
Disable
12-101
UPU FICS Postal
611
F1h 63h
Disable
12-102
Mailmark
1337
F8h 05h 39h
Disable
12-102
Parameter
Default
Page Number
Postal Codes
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 180
12 - 8
DS2208 Digital Scanner Product Reference Guide
Enable/Disable All Code Types Scan the Disable All Code Types bar code to disable all symbologies. This is useful when enabling only a few code types. Scan Enable All Code Types to enable all symbologies. This is useful if you need to disable only a few code types.
Disable All Code Types
Enable All Code Types
UPC/EAN/JAN UPC-A Parameter # 1 SSI # 01h Scan one of the following bar codes to enable or disable UPC-A.
*Enable UPC-A (1)
Disable UPC-A (0)
Page 181
Symbologies
UPC-E Parameter # 2 SSI # 02h Scan one of the following bar codes to enable or disable UPC-E.
*Enable UPC-E (1)
Disable UPC-E (0)
UPC-E1 Parameter # 12 SSI # 0Ch Scan one of the following bar codes to enable or disable UPC-E1. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
Enable UPC-E1 (1)
*Disable UPC-E1 (0)
12 - 9
Page 182
12 - 10
DS2208 Digital Scanner Product Reference Guide
EAN-8/JAN-8 Parameter # 4 SSI # 04h Scan one of the following bar codes to enable or disable EAN-8/JAN-8.
*Enable EAN-8/JAN-8 (1)
Disable EAN-8/JAN-8 (0)
EAN-13/JAN-13 Parameter # 3 SSI # 03h Scan one of the following bar codes to enable or disable EAN-13/JAN-13.
*Enable EAN-13/JAN-13 (1)
Disable EAN-13/JAN-13 (0)