Page 163

CHAPTER 11 KEYBOARD WEDGE INTERFACE Introduction This chapter describes how to set up a keyboard wedge interface with the scanner. The scanner connects between the keyboard and host computer and translates bar code data into keystrokes, which the host accepts as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through. The scanner ships with the settings shown in Table 11-1 on page 11-3 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary.

Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

To return all features to default values, scan a bar code in Default Parameters on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates default

*Enable Parameter

Feature/option

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to select a medium keystroke delay, scan the Medium Delay (20 msec) bar code under Keystroke Delay on page 11-5. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See the parameter descriptions for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Page 164

11 - 2 DS2208 Digital Scanner Product Reference Guide

Connecting a Keyboard Wedge Interface Power supply (if required)

Male DIN connector

Keyboard connector

Figure 11-1

Female DIN connector

Keyboard Wedge Connection

NOTE Interface cables vary depending on configuration. The connectors can be different than those illustrated in Figure 11-1, but the steps to connect the scanner are the same.

1.

Turn off the host and unplug the keyboard connector.

2.

Attach the modular connector of the Y-cable to the cable interface port on the digital scanner. See Installing the Interface Cable on page 1-3.

3.

Connect the round male DIN host connector of the Y-cable to the keyboard port on the host device.

4.

Connect the round female DIN keyboard connector of the Y-cable to the keyboard connector.

5.

If required, attach the optional power supply to the connector in the middle of the Y-cable.

6.

Ensure that all connections are secure.

7.

Turn on the host system.

8.

The digital scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, scan IBM PC/AT & IBM PC Compatibles on page 11-4.

9.

To modify any other parameter options, scan the appropriate bar codes in this guide.

If problems occur with the system, see Troubleshooting on page 4-3.

Page 165

Keyboard Wedge Interface 11 - 3

Keyboard Wedge Parameter Defaults Table 11-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in Keyboard Wedge Host Parameters on page 11-4. NOTE See Appendix B, Country Codes for Keyboard Wedge Country Keyboard Types (Country Codes).

See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Table 11-1

Keyboard Wedge Host Default Table Parameter

Default

Page Number

Keyboard Wedge Host Parameters Keyboard Wedge Host Type

IBM AT Notebook

11-4

Bar Codes with Unknown Characters

Send Bar Codes with Unknown Characters

11-4

Keystroke Delay

No Delay

11-5

Intra-keystroke Delay

Disable

11-5

Alternate Numeric Keypad Emulation

Enable

11-6

Quick Keypad Emulation

Enable

11-6

Simulated Caps Lock

Disable

11-7

Caps Lock Override

Disable

11-7

Convert Case

Do Not Convert

11-8

Function Key Mapping

Disable

11-8

FN1 Substitution

Disable

11-9

Send Make and Break

Send

11-9

Page 166

11 - 4 DS2208 Digital Scanner Product Reference Guide

Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below. NOTE For a list of supported scanner functionality by communication protocol, see Appendix J, Communication Protocol Functionality.

IBM PC/AT & IBM PC Compatibles

*IBM AT Notebook

Bar Codes with Unknown Characters Unknown characters are characters the host does not recognize. Scan Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The scanner issues no error beeps. Scan Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The scanner issues an error beep.

*Send Bar Codes with Unknown Characters

Do Not Send Bar Codes with Unknown Characters

Page 167

Keyboard Wedge Interface 11 - 5

Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan one of the following bar codes to increase the delay when hosts require a slower data transmission.

*No Delay

Medium Delay (20 msec)

Long Delay (40 msec)

Intra-keystroke Delay Scan Enable Intra-keystroke Delay to insert an additional delay between each emulated key press and release. This also sets Keystroke Delay to a minimum of 5 msec.

Enable Intra-keystroke Delay

*Disable Intra-keystroke Delay

Page 168

11 - 6 DS2208 Digital Scanner Product Reference Guide

Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Appendix B, Country Codes in a Microsoft® operating system environment. NOTE If your keyboard type is not listed in the country code list (see USB and Keyboard Wedge Country Keyboard Types (Country Codes) on page B-2), disable Quick Keypad Emulation on page 11-6 and ensure Alternate Numeric Keypad Emulation on page 11-6 is enabled.

*Enable Alternate Numeric Keypad

Disable Alternate Numeric Keypad

Quick Keypad Emulation This enables faster keypad emulation where character value sequences are only sent for characters not found on the keyboard. NOTE This option applies only when Alternate Numeric Keypad Emulation is enabled.

*Enable Quick Keypad Emulation

Disable Quick Keypad Emulation

Page 169

Keyboard Wedge Interface 11 - 7

Simulated Caps Lock Scan Enable Caps Lock to invert upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion occurs regardless of the keyboard’s Caps Lock state. Note that Simulated Caps Lock applies to ASCII alpha characters only.

Enable Caps Lock

*Disable Caps Lock

Caps Lock Override Scan Enable Caps Lock Override for AT or AT Notebook hosts to preserve the case of the data regardless of the state of the Caps Lock key. Therefore, an ‘A’ in the bar code transmits as an ‘A’ regardless of the setting of the keyboard’s Caps Lock key.

Enable Caps Lock Override

*Disable Caps Lock Override NOTE If both Simulated Caps Lock and Caps Lock Override are enabled, Caps Lock Override takes precedence.

Page 170

11 - 8 DS2208 Digital Scanner Product Reference Guide

Convert Case Scan one of the following bar codes to convert all bar code data to the selected case. NOTE Convert Case applies to ASCII characters only.

Convert to Upper Case

Convert to Lower Case

*Do Not Convert

Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table I-1 on page I-1). Scan Enable Function Key Mapping to send the keys in bold in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not you enable this parameter.

Enable Function Key Mapping

*Disable Function Key Mapping

Page 171

Keyboard Wedge Interface 11 - 9

FN1 Substitution Scan Enable FN1 Substitution to replace FN1 characters in an EAN128 bar code with a user-selected keystroke (see FN1 Substitution Values on page 5-34).

Enable FN1 Substitution

*Disable FN1 Substitution

Send Make and Break Scan Send Make and Break Scan Codes to prevent sending the scan codes for releasing a key.

*Send Make and Break Scan Codes

Send Make Scan Code Only

NOTE Windows-based systems must use Send Make and Break Scan Codes.

Page 172

11 - 10DS2208 Digital Scanner Product Reference Guide

Keyboard Map The following keyboard map is a reference for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 5-31.

7014

5001

5002

5003

5004

5005

5006

5007

5008

5009

5010

5012

5011

7008

7009

7010

7007

7006 7001

7011

7012

7003

7002

7004

7005

7013

7015

7017

Figure 11-2

7016

7018

IBM PS2 Type Keyboard

ASCII Character Set for Keyboard Wedge NOTE Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, if you enable Code 39 Full ASCII and scan +B, it transmits as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >.

See Appendix I, ASCII Character Sets for the following: • ASCII Character Set (Table I-1 on page I-1) • ALT Key Character Set (Table I-2 on page I-6) • GUI Key Character Set (Table I-3 on page I-7) • F Key Character Set (Table I-5 on page I-10) • Numeric Key Character Set (Table I-6 on page I-11) • Extended Key Character Set (Table I-7 on page I-12).