Page 157

CHAPTER 10 IBM 468X / 469X INTERFACE Introduction This chapter describes how to set up the scanner with an IBM 468X/469X host. The scanner ships with the settings shown in Table 10-1 on page 10-3 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary.

Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

To return all features to default values, scan Set Factory Defaults on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates default

*Enable Parameter

Feature/option

Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to select the Port 9B address, scan the Hand-Held Scanner Emulation (Port 9B) bar code under Port Address on page 10-4. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See the parameter descriptions for this procedure.

Page 158

10 - 2 DS2208 Digital Scanner Product Reference Guide

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Connecting an IBM 468X/469X Host Connect the scanner directly to the host computer.

Interface cable Host port connector

Figure 10-1

IBM Connection

NOTE Interface cables vary depending on configuration. The connectors can be different than those illustrated in Figure 10-1, but the steps to connect the scanner are the same.

1.

Attach the modular connector of the IBM 46XX interface cable to the cable interface port on the scanner. See Installing the Interface Cable on page 1-3.

2.

Connect the other end of the IBM 46XX interface cable to the appropriate port on the host (typically Port 9).

3.

The scanner automatically detects the host interface type, but there is no default setting. Scan the appropriate bar code from Port Address on page 10-4 to select the port address.

4.

To modify any other parameter options, scan the appropriate bar codes in this chapter. NOTE The only required configuration is the port address. The IBM system typically controls other scanner parameters.

If problems occur with the system, see Troubleshooting on page 4-3.

Page 159

IBM 468X / 469X Interface 10 - 3

IBM Parameter Defaults Table 10-1 lists defaults for IBM host parameters. Change these values in one of two ways: • Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall default parameter values, see Default Parameters on page 5-5. • Configure the scanner using the 123Scan2 configuration program. See Chapter 2, 123Scan and Software Tools. NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.

Table 10-1

IBM 468X/469X Interface Parameter Defaults Parameter

Default

Page Number

IBM 468X/469X Host Parameters Port Address

None

10-4

Convert Unknown to Code 39

Disable

10-5

RS-485 Beep Directive

Ignore

10-5

RS-485 Bar Code Configuration Directive

Ignore

10-6

Page 160

10 - 4 DS2208 Digital Scanner Product Reference Guide

IBM Host Parameters Port Address Scan one of the following bar codes to select the IBM 468X/469X port. NOTE Scanning a Port Address bar code enables the RS-485 interface on the scanner.

NOTE For a list of supported scanner functionality by communication protocol, see Appendix J, Communication Protocol Functionality.

*None

Hand-Held Scanner Emulation (Port 9B)

Non-IBM Scanner Emulation (Port 5B)

Table-Top Scanner Emulation (Port 17)

Page 161

IBM 468X / 469X Interface 10 - 5

Convert Unknown to Code 39 Scan one of the following bar codes to enable or disable converting unknown bar code type data to Code 39.

Enable Convert Unknown to Code 39

*Disable Convert Unknown to Code 39

RS-485 Beep Directive The IBM RS-485 host can send a beeper configuration request to the scanner. Scan Ignore Beep Directive to prevent the scanner from processing the host request. All directives are still acknowledged to the host as if they were processed.

Honor Beep Directive

*Ignore Beep Directive

Page 162

10 - 6 DS2208 Digital Scanner Product Reference Guide

RS-485 Bar Code Configuration Directive The IBM RS-485 host can enable and disable code types. Scan Ignore Bar Code Configuration Directive to prevent the scanner from processing the host request. All directives are still acknowledged to the IBM RS-485 host as if they were processed.

Honor Bar Code Configuration Directive

*Ignore Bar Code Configuration Directive