Page 183
Symbologies
Bookland EAN Parameter # 83 SSI # 53h Scan one of the following bar codes to enable or disable Bookland EAN.
Enable Bookland EAN (1)
*Disable Bookland EAN (0)
NOTE If you enable Bookland EAN, select a Bookland ISBN Format. Also set Decode UPC/EAN/JAN Supplementals on page 12-13 to either Decode UPC/EAN/JAN with Supplementals Only, Autodiscriminate UPC/EAN/JAN With Supplementals, or Enable 978/979 Supplemental Mode.
12 - 11
Page 184
12 - 12
DS2208 Digital Scanner Product Reference Guide
Bookland ISBN Format Parameter # 576 SSI # F1h 40h If you enabled Bookland EAN using Bookland EAN on page 12-11, select one of the following formats for Bookland data: • Bookland ISBN-10 - The scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered Bookland in this mode. • Bookland ISBN-13 - The scanner reports Bookland data (starting with either 978 or 979) as EAN-13 in 13-digit format to meet the 2007 ISBN-13 protocol.
*Bookland ISBN-10 (0)
Bookland ISBN-13 (1) NOTE For Bookland EAN to function properly, first enable Bookland EAN using Bookland EAN on page 12-11, and then set Decode UPC/EAN/JAN Supplementals on page 12-13 to either Decode UPC/EAN/JAN with Supplementals Only, Autodiscriminate UPC/EAN/JAN With Supplementals, or Enable 978/979 Supplemental Mode.
ISSN EAN Parameter # 617 SSI # F1h 69h Scan one of the following bar codes to enable or disable ISSN EAN.
Enable ISSN EAN (1)
*Disable ISSN EAN (0)
Page 185
Symbologies
12 - 13
Decode UPC/EAN/JAN Supplementals Parameter # 16 SSI # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available: • Decode UPC/EAN/JAN with Supplementals Only - The scanner only decodes UPC/EAN/JAN symbols with supplemental characters, and ignores symbols without supplementals. • Ignore UPC/EAN/JAN Supplementals - When presented with a UPC/EAN/JAN plus supplemental symbol, the scanner decodes UPC/EAN/JAN and ignores the supplemental characters. • Autodiscriminate UPC/EAN/JAN with Supplementals - The scanner decodes UPC/EAN/JAN symbols with supplemental characters immediately. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 12-16 before transmitting its data to confirm that there is no supplemental. Select one of the following Supplemental Mode options to immediately transmit EAN-13 bar codes starting with that prefix that have supplemental characters. If the symbol does not have a supplemental, the scanner must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page 12-16 before transmitting the data to confirm that there is no supplemental. The scanner transmits UPC/EAN/JAN bar codes that do not have that prefix immediately. • Enable 378/379 Supplemental Mode • Enable 978/979 Supplemental Mode NOTE If you select 978/979 Supplemental Mode and are scanning Bookland EAN bar codes, see Bookland EAN on page 12-11 to enable Bookland EAN, and select a format using Bookland ISBN Format on page 12-12.
• Enable 977 Supplemental Mode • Enable 414/419/434/439 Supplemental Mode • Enable 491 Supplemental Mode • Enable Smart Supplemental Mode - This applies to EAN-13 bar codes starting with any prefix listed previously. • Supplemental User-Programmable Type 1 - This applies to EAN-13 bar codes starting with a 3-digit user-defined prefix. Set this using User-Programmable Supplementals on page 12-16. • Supplemental User-Programmable Type 1 and 2 - This applies to EAN-13 bar codes starting with either of two 3-digit user-defined prefixes. Set the prefixes using User-Programmable Supplementals on page 12-16. • Smart Supplemental Plus User-Programmable 1 - This applies to EAN-13 bar codes starting with any prefix listed previously or the prefix set using User-Programmable Supplementals on page 12-16. • Smart Supplemental Plus User-Programmable 1 and 2 - This applies to EAN-13 bar codes starting with any prefix listed previously or one of the two user-defined prefixes set using User-Programmable Supplementals on page 12-16. NOTE To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters.
Page 186
12 - 14
DS2208 Digital Scanner Product Reference Guide
Decode UPC/EAN/JAN Supplementals (continued)
Decode UPC/EAN/JAN With Supplementals Only (1)
*Ignore UPC/EAN/JAN Supplementals (0)
Autodiscriminate UPC/EAN/JAN with Supplementals (2)
Enable 378/379 Supplemental Mode (4)
Enable 978/979 Supplemental Mode (5)
Enable 977 Supplemental Mode (7)
Page 187
Symbologies
12 - 15
Decode UPC/EAN/JAN Supplementals (continued)
Enable 414/419/434/439 Supplemental Mode (6)
Enable 491 Supplemental Mode (8)
Enable Smart Supplemental Mode (3)
Supplemental User-Programmable Type 1 (9)
Supplemental User-Programmable Type 1 and 2 (10)
Smart Supplemental Plus User-Programmable 1 (11)
Smart Supplemental Plus User-Programmable 1 and 2 (12)
Page 188
12 - 16
DS2208 Digital Scanner Product Reference Guide
User-Programmable Supplementals Supplemental 1: Parameter # 579 SSI # F1h 43h Supplemental 2: Parameter # 580 SSI # F1h 44h If you selected a Supplemental User-Programmable option from Decode UPC/EAN/JAN Supplementals on page 12-13, scan User-Programmable Supplemental 1, and then scan three bar codes from Appendix G, Numeric Bar Codes to set the 3-digit prefix. To set a second 3-digit prefix, scan User-Programmable Supplemental 2, and then scan three bar codes from Appendix G, Numeric Bar Codes. The default is 000 (zeroes).
User-Programmable Supplemental 1
User-Programmable Supplemental 2
UPC/EAN/JAN Supplemental Redundancy Parameter # 80 SSI # 50h If you selected Autodiscriminate UPC/EAN/JAN with Supplementals, this option sets the number of times to decode a symbol without supplementals before transmission. The range is from two to 30. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals. The default is 10. To set a redundancy value, scan the following bar code, and then scan two bar codes from Appendix G, Numeric Bar Codes. Enter a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel on page G-3.
UPC/EAN/JAN Supplemental Redundancy
Page 189
Symbologies
12 - 17
UPC/EAN/JAN Supplemental AIM ID Format Parameter # 672 SSI # F1h A0h If Transmit Code ID Character on page 5-30 is set to AIM Code ID Character, scan one of the following bar codes to select an output format when reporting UPC/EAN/JAN bar codes with supplementals: • Separate - Transmit UPC/EAN/JAN with supplementals with separate AIM IDs but one transmission, i.e., ]E<0 or 4><data>]E<1 or 2>[supplemental data] • Combined – Transmit UPC/EAN/JAN with supplementals with one AIM ID and one transmission, i.e., ]E3<data+supplemental data> • Separate Transmissions - Transmit UPC/EAN/JAN with supplementals with separate AIM IDs and separate transmissions, i.e., ]E<0 or 4><data> ]E<1 or 2>[supplemental data]
Separate (0)
*Combined (1)
Separate Transmissions (2)
Page 190
12 - 18
DS2208 Digital Scanner Product Reference Guide
Transmit UPC-A Check Digit Parameter # 40 SSI # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan one of the following bar codes to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data.
*Transmit UPC-A Check Digit (1)
Do Not Transmit UPC-A Check Digit (0)
Transmit UPC-E Check Digit Parameter # 41 SSI # 29h The check digit is the last character of the symbol used to verify the integrity of the data. Scan one of the following bar codes to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data.
*Transmit UPC-E Check Digit (1)
Do Not Transmit UPC-E Check Digit (0)
Page 191
Symbologies
12 - 19
Transmit UPC-E1 Check Digit Parameter # 42 SSI # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan one of the following bar codes to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data.
*Transmit UPC-E1 Check Digit (1)
Do Not Transmit UPC-E1 Check Digit (0)
Page 192
12 - 20
DS2208 Digital Scanner Product Reference Guide
UPC-A Preamble Parameter # 34 SSI # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. Select the appropriate option for transmitting a UPC-A preamble to match the host system: • Transmit System Character only • Transmit System Character and Country Code (“0” for USA) • Transmit no preamble.
No Preamble (<DATA>) (0)
*System Character (<SYSTEM CHARACTER> <DATA>) (1)
System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)
(2)