Page 21

4.

Hardware Installation

The hardware installation procedure includes the following steps: 1.

Connect the VIP unit to an appropriate power supply (see Section 4.1).

2.

Use the Set-Up Switches to select default communication parameters and options (see Section 4.2).

3.

Reset the VIP unit and clear the flash memory (see Section 4.3).

4.

Connect the data cables, network cable and telephone line (see Section 4.4)

4.1.

Connect the VIP to Power Supply Notes:

• When Switch 8 is UP (enable Power Up Default) and there is a power interruption, baud rates will return to the default values selected by Set-Up Switches 1 through 5.

• After configuring the unit with menu selected parameters, you may wish to return Set-Up Switch 8 to the DOWN position. This will cause the VIP to use menu selected parameters whenever the unit is powered off and on.

CAUTION: This device should only be operated with the type of power source indicated on the instrument nameplate. If you are not sure of the type of power service available, please contact your local power company. 4.1.1. AC Powered Units Plug the power cable into the receptacle on the VIP back panel. The VIP features a self-adjusting power supply that automatically adapts for 115 or 230 VAC. Place the AC Power Switch in the ON position to apply power, the ON indicator will light and the RDY indicator will flash.

4-1

Page 22

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

Figure 4.1: DC Terminal Block Assembly

4.1.2. DC Powered Units Attach the wires from your -48V DC power source (0.2 Amp Max.) to the screw terminals, and then connect your ground line to the ground screw.

4.2.

Set-Up Switches

The Set-Up Switches select default communication parameters and enable options such as Dialback Security, the Console Port Password, and Power Up Default. Note that operating parameters are selected via the port configuration menus as described in Section 5.4. 4.2.1. Default Baud Rate for Console Port (Sw1, Sw2, Sw3) Set-Up Switches One, Two, and Three select the default Baud Rate for the Console Port. After the VIP is installed, the Port Configuration menu (Main Menu, item 22) can be used to select the operating baud rate for the Console Port. Baud

Switch 1

Switch 2

Switch 3

9600 *

Down

Down

Down

38.4 K

Up

Down

Down

19.2 K

Down

Up

Down

4800

Up

Up

Down

2400

Down

Down

Up

1200

Up

Down

Up

600

Down

Up

Up

300

Up

Up

Up

* = Factory Setting

4-2

Page 23

Hardware Installation

4.2.2. Default Baud Rate for PBX Port A, PBX Port B, and AUX Port (Sw4, Sw5) Switches Four and Five select default Baud Rates for PBX Ports A and B and the AUX Port. The Port Configuration menus can be used to define operating baud rates as described in Section 5.4. Note that NLJ-VIP units do not include PBX Port B or the AUX Port. Baud

Switch 4

Switch 5

9600 *

Down

Down

4800

Up

Down

1200

Down

Up

300

Up

Up

* = Factory Setting 4.2.3. Dialback Security Mode (Sw6) This feature provides additional security for modem access to the Command Mode. Dialback Security will prompt callers to enter a password. If a valid password is entered, the VIP will disconnect and then call the user-defined number for that password before allowing access to Command Mode. Section 5.4.4.1 describes the procedure for configuring Dialback Security. Switch 6

Dialback Security Mode

Down *

Dialback Security Disabled

Up

Dialback Security Enabled

* = Factory Setting 4.2.4. Console Port Password (Sw7) Switch Seven enables/disables the Console Port Password. The default Supervisor Password is "SUPER"; the default User 1 Password is "SMDR", the default User 2 Password is undefined. For a summary of User Mode and Supervisor Mode functions, please refer to Appendix C. Note: If the Console Port password is disabled, the VIP will always start up in Supervisor Mode. Switch 7

Console Port Password

Down *

Password Not Required

Up

Password Required

* = Factory Setting

4-3

Page 24

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

4.2.5. Power Up Default (Sw8) The Power Up Default allows the user to reset communication parameters to default settings without entering Command Mode. Note: If you have changed Set-Up Switches 1 through 5, and you wish to clear all menu selected parameters, Switch 8 should be set in the UP position. This will allow default parameters selected by the Set-Up Switches to take effect when the VIP is powered up. When the Power Up Default is enabled, the VIP will reset the following parameters after an interruption in power:

• Input Port Communication Parameters: The Baud rate for PBX

Ports A and B, and the AUX Port are set according to the Set-Up Switches, rather than command selected parameters. All three ports will be set at 7 bits, even parity, one stop bit. Note that NLJ-VIP units do not include PBX Port B or the AUX Port.

• Console Port Communication Parameters: The Baud rate will be set according to the Set-Up Switches. The Port will also be set for 8 bits, no parity, one stop bit. • Modem Port Communication Parameters: The port will be set to 57600, 8 bits, no parity, one stop bit. • Passwords: The Supervisor Password will default to "SUPER". The User 1 Password will default to "SMDR". In the default state, the User 2 Password is not defined. CAUTION: If Set-Up Switch 8 is UP (enable Power Up Default), and there is a loss of power, port parameters will be set to the default values selected by Set-Up Switches 1 - 6 rather than the menu selected parameters. If the Power Up Default is disabled (Sw8 = Down), when there is a power interruption, The VIP will be configured according to the parameters currently saved in flash memory. Switch 8

Power Up Default

Down *

Disabled (Use Saved Port Parameters)

Up

Enabled (Re-Set to Switch-Selected Default Port Parameters)

* = Factory Setting

4-4

Page 25

Hardware Installation

4.3.

Reset to Defaults

This procedure will reset the VIP to the settings indicated by the Set-Up switches, reset all menu selected parameters to factory defaults, and clear memory. When the unit is shipped from the factory, defaults are reset and the memory is cleared. However, if the VIP has been previously installed, or if you have changed switch settings, this procedure should be performed. It is also recommended to reset the unit after installing additional memory modules. Notes:

• When this procedure is performed, all menu defined parameters will be cleared. If the unit has already been configured, parameter settings should be saved (as described in Section 15.2), before beginning this procedure.

• If the VIP unit has the base 512K memory option (no SIMMs), all stored data will be cleared. If the unit has collected data, it is recommended to retrieve stored data (as described in Section 16) before beginning this procedure.

To reset defaults and clear memory, proceed as follows: 1.

Press the Main Power Switch to the OFF position.

2.

Press and hold the Reset Button (located on the back panel) while pressing the Main Power Switch to the ON position. Continue to hold the Reset Button until the front panel indicators blink twice.

3.

After the indicators blink, release the Reset Button. After a brief pause, the front panel indicators will blink three times. This indicates that the reset procedure is complete.

4-5

Page 26

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

4.4.

Connecting Cables and Phone Line

Your cable layout should account for the following factors: Command Mode Access: The VIP provides several methods for accessing Command Mode

• Network Access: The VIP is managed via Ethernet. Note that initial setup cannot be performed via network.

• Local Access: The VIP is managed by a local PC connected to the Console Port.

• Remote Access: The VIP is managed by a remote PC that communicates with the unit via modem.

• Multiple Access: The VIP can be managed via Network, Console Port, or Modem.

Alarm Actions: The VIP offers several methods that can be used to notify users when an alarm has been generated:

• SNMP Trap: An SNMP Trap is sent to a network management station.

• Console Port Action: Alarms are sent to a local PC connected to the Console Port.

• Modem or Pager: Alarms are sent to a remote PC or Pager. • Email or Text Message: Alarms are sent via email or text message, to up to two user-defined email addresses.

• Output Contacts: (Optional - Not Available on NLJ-VIP units.) The Output Contacts can be opened or closed.

• Combination of Methods: Each alarm is directed to a different target. The alarm configuration screens select notification methods for each alarm.

The physical layout is determined by the Command Mode access method and Alarm Actions required for your application. Determine which method(s) will be used and install cables as outlined in the following sections. CAUTION: Prior to connecting data lines, make certain that cables are compatible with The VIP. Please refer to the interface descriptions in Appendix B.

4-6

Page 27

Hardware Installation

4.4.1. PBX Inputs A and B and AUX Port The PBX Inputs and the AUX port are used for connection to your PBX SMDR Port. The AUX Port can be connected to a third PBX, or used to collect data from, or pass commands to other devices. For a description of the port interface, please refer to Appendix B. Note that NLJ-VIP units do not include PBX Port B or the AUX Port. 4.4.2. Modem Port When an outside phone line is connected to the Modem Port, the VIP can be managed and polled via modem. When an alarm is generated, the VIP can also provide notification via modem or pager. 4.4.3. Console Port The Console Port can be connected to a local PC, which is used to manage and poll the VIP unit. Please refer to Appendix B for a description of the Console Port interface. 4.4.4. Network Port The Network Port allows connection to a TCP/IP network. When installation is complete, the VIP unit can be managed and polled via network. The VIP can also provide alarm notification via SNMP trap. Use a straight wired 10Base-T cable. Note: The VIP features a 10Base-T, half duplex network interface. When connecting to a 100Base-T interface, most router switches will autosense to determine if the device is 100Base-T or 10BaseT, and then configure the network interface accordingly. If your router switch does not autosense, the network interface port must be manually set to 10Base-T, half duplex mode.

4-7

Page 28

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

4-8

Page 29

5. Configuration When the VIP unit is shipped from the factory, options and parameters are set to fit the requirements of most call accounting applications. In many cases, if you do not choose to include the VIP's advanced features, no further configuration is required. However, if you do intend to use advanced features (such as the Data Filter or Alarm Filter), or if your application requires parameters other than the defaults described in this section, the unit must be properly configured. This section describes how to reconfigure the VIP to meet the requirements of almost any data collection application. Although The VIP provides a substantial assortment of advanced program features, it is not necessary to include all of these features in your system configuration. You may wish to complete the basic set-up first, and then add optional features as needed. When configuring the unit, note that the Status Screens can be accessed via item 1 in the Main Menu. This allows you to determine the current state of any feature, and verify that parameters are correctly defined. For more information on the Status Screens, please refer to Section 7.

5.1. Access to the Command Mode When the command mode is active, the unit will display a series of menus used to select parameters, enable options, and retrieve stored data. During initial configuration, command mode can only be accessed via the Console Port or Modem Port. After network parameters have been defined, you will also be able to access command mode via the Network Port. To access command mode for initial configuration, proceed as follows: PollCat NetLink-VIP Main Menu:

Supervisor Mode

FUNCTIONS:

CONFIGURATION:

1. Status Displays 2. Buffer Functions 3. System Functions 4. System Diagnostics 5. ^Bxx Command Help 6. Recall Parameters 7. Save Parameters 8. Exit Command Mode

21. Default Parameters 22. Port Configuration 23. System Parameters 24. Scheduled Action Parameters 25. Alarm Configuration 26. Data Filter Configuration 27. FTP Push Configuration 28. FTP Server Configuration

Enter selection ...

Figure 5.1: Main Menu

5-1

Page 30

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

1.

2.

3.

Local Access: To communicate via the Console Port, start your communications program (e.g. ProComm™). a)

If Set-Up Switch 7 is UP (enable Console Port Password), the system will send the "PollCat-NetLink" (Password) Prompt.

b)

Key in the password (case-sensitive), press [Enter]. The Default Supervisor Password is SUPER.

Access Via Modem: Start your communications program (e.g., ProComm) and dial the VIP. a)

The unit will send the "PollCat-NetLink" (Password) prompt after the carrier is detected.

b)

Key in the password (case-sensitive), press [Enter]. The Default Supervisor Password is SUPER.

Access via Network: During initial configuration, the VIP cannot be accessed via Network, because parameters such as the IP address and gateway mask have not been defined yet. After network parameters have been defined (see Section 5.4.5), a Telnet session can be established using the following format: telnet ipaddress port [Enter] Where: ipaddress port

The VIP's IP Address (Optional) The desired Port Number. If omitted, telnet will connect to port #23 by default; Command Echo will be set according to the VIP's current configuration, and $FF Stuffing will be enabled. Options: 2001 Behaves same as port #23. 3001 Preconfigured with Echo enabled, and $FF Stuffing Off.

Notes: • The VIP will allow 3 attempts to enter a valid password. If a valid password is not entered in 3 attempts, the VIP will disconnect. • If an invalid password is entered, the VIP will respond with the ERROR message. After a brief pause, the VIP Main Menu will appear as shown in Figure 5.1.

5-2