1. Introduction The PollCat NetLink-VIP and PollCat NetLink Jr.-VIP (NLJ-VIP) Call Accounting Terminals are highly reliable, PBX data recorders designed for SMDR/CDR data collection and alarm monitoring. Collected call records can be retrieved via TCP/IP network, via FTP client, via modem, or by a local PC connected directly to the VIP unit. In addition to storing call data, the VIP can also monitor call records for suspicious phone activity or critical alarm conditions. When an alarm is detected, the unit can immediately notify the proper personnel by pager, modem, or SNMP trap. The VIP also provides secure access to connected serial devices such as PBX maintenance ports or Console/AUX ports. Network and Modem Access All command functions, including data retrieval and unit configuration, can be accessed via network, modem or local PC. When the VIP is installed in a TCP/IP environment, Telnet is used to access the command mode. If outof-band access is required, you can also dial-up the VIP’s internal modem. Stored data can be reliably retrieved using your terminal emulation program, an FTP client or Zmodem protocol. Password protection and dialback security prevent unauthorized access to control functions. Nonvolatile Flash Memory The VIP uses reliable, low-cost flash memory to store call records and operating parameters. This eliminates the need to check and replace depleted batteries. If power to the unit is lost or interrupted, stored data can be retained indefinitely without worrying about low or dead batteries. The VIP is available with 512 K to 64 Megabytes of internal memory. For NetLink-VIP units only, if more memory is needed later, additional memory modules can be easily snapped into place. SNMP Traps Alarm messages, memory full status, and a variety of other conditions can be reported to your network manager via standard SNMP traps. SNMP Traps can be used to provide notification when an alarm event occurs, or to perform a wellness check at user selected time intervals.
1-1
Page 12
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
Up to Four PBX Inputs The NetLink-VIP includes four separate data input ports; two PBX ports, an Auxiliary Port and the PBX IP Port. This allows the unit to collect data from four different sources. The Auxiliary Port can be connected to a third PBX, or other data generating device, or used to pass commands to a connected device such as WTI’s IPS-800 Internet Power Switch. Communication parameters can be individually defined for each port. When the unit is polled, data from the three ports can either be combined, or read separately. Note that the NLJ-VIP includes only two input ports; the PBX A Port and the PBX IP Port. NetLink-VIP Units and NLJ-VIP Units This User’s Guide discusses both NetLink-VIP units and NLJ-VIP (NetLink Jr.-VIP) units. Throughout this User’s Guide, both units are referred to as "VIP." The NetLink-VIP includes four input ports, and is also available with expanded memory and the Input Contact option. The NLJ-VIP includes two input ports and 512K of flash memory. All other features function identically, except where noted. Disclaimer on Toll Fraud We do not guarantee that if you use the VIP, you will not become the victim of toll fraud. We provide this device to assist you in minimizing your exposure to such losses. By monitoring call records as they are received, you can potentially catch calls that should not be made before they escalate and cost you large sums of money. However, responding to alarms and determining what is fraud and abuse are still up to you. Western Telematic, Incorporated assumes no responsibility for any losses due to improper use of this product. Typographic Conventions In this user’s guide, typefaces and characters are used as follows: ^ (e.g. ^B)
Indicates a key combination used to invoke a command. For example, “^B” (Control B) indicates that the [Ctrl] key and [B] key should be pressed simultaneously.
COURIER FONT Indicates characters typed on the keyboard. For example, ^B16 or ^B01. [Bold Font]
1-2
Text set in bold face and enclosed in square brackets indicates a specific key. For example, [Enter] or [Esc].
Page 13
2.
Unit Description
2.1.
Front Panel Indicators
POLLCAT
®
SYSTEM
MEMORY
MODEM
ON RDY ALM
>0% >25 >50 >75 FULL
OH DCD
1
2
NetLink-VIP
INPUT CP
3
AUX
A
B
CDR Data Recorder
4
Figure 2.1: Front Panel Indicators (NetLink-VIP Shown)
➀ SYSTEM Indicators: • ON: Lights when AC Power is applied to the unit. • RDY: Flashes slowly to indicate the unit is operational. • ALM: Lights when a Toll Fraud Alarm or PBX Inactivity Alarm is triggered.
➁ MEMORY Indicators: A bank of five LEDs which light to indicate approximate memory usage.
➂ MODEM Indicators: Two LEDs which indicate modem conditions as follows:
• OH: (Off Hook) Lights when modem is off-hook. • DCD: (Data Carrier Detect) Lights when carrier is detected.
➃ INPUT Indicators: A bank of four LEDs which indicate data reception as follows:
• CP: Lights when commands are received via the Console Port. • AUX: Lights when data is received via the AUX Port. • A: Lights when data is received via PBX Port A. • B: Lights when data is received via PBX Port B. Note: The NLJ-VIP Model does not include the "B" or "AUX" input ports or LED indicators for these ports.
2-1
Page 14
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
2.2.
Back Panel
7
6
8 I/O MONITOR OPTION
PBX INPUTS (DTE)
B
A
AUX
2
1
SETUP
(DCE)
4
3
RESET
5
Figure 2.2: Back Panel (NetLink-VIP Model)
7
6
CONSOLE PORT
PBX INPUT
(DCE)
1
3
(DTE)
2
RESET
SETUP
5
4
Figure 2.3: Back Panel (NLJ-VIP Model)
➀ AC Power Components: (AC Units Only) On/Off Switch and
Power Cable receptacle. DC units include a terminal block assembly (Figure 4.1) in place of the power cable receptacle.
➁ PBX Input Connector(s): DB9 Connector(s) (DTE) used for connection to your PBX SMDR Port(s).
Notes: • NetLink-VIP Models include three PBX Input Connectors for Port A, Port B and the AUX Port. • NetLink-Jr.-VIP models include only one PBX Input Connector and do not include the AUX Port. • The AUX Port on the NetLink-VIP model can be connected to a PBX, or used to pass commands to a connected device.
➂ Console Port: For connection to a local PC or terminal. 2-2
Page 15
Unit Description
➃ Set-Up Switches: A bank of eight dip switches that are used to select default options and communication settings.
➄ Reset Button: Used to reset the VIP to defaults and clear memory as described in Section 4.3.
➅ Network Port: A 10Base-T connector with LED indicator(s). When a network connection is present, the LINK indicator will light.
➆ Modem Port: For connection to a telecommunications line. ➇ I/O Monitor: (Not Shown - Option for NetLink-VIP Model only) The optional I/O monitor allows the NetLink-VIP to monitor externally supplied signals, and open or close contacts in response to alarms or according to a user-defined schedule.
2-3
Page 16
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
2-4
Page 17
3.
Quick Start Guide
This Quick Start Guide describes a simplified installation procedure for the VIP hardware, which will allow you to communicate with the unit in order to demonstrate basic features and check for proper operation. Note that this Quick Start Guide does not provide a detailed description of unit configuration, or discuss advanced operating features in detail. In order to take full advantage of the complete range of features offered by the unit, it is recommended to review the remainder of this User's Guide after performing the Quick Start procedure.
3.1.
Hardware Installation
3.1.1. Apply Power to the VIP Refer to the power rating nameplate on the VIP back panel, and then connect the unit to an appropriate power source. The VIP features a self-adjusting power supply that automatically adapts for 115 or 230 VAC operation. Set the Master Power Switch on the VIP back panel to the ON position; the front panel indicators should light. After a brief pause, the RDY indicator should begin to flash, indicating that the unit is ready to receive commands. 3.1.2. Connect your PC to the VIP In order to configure the VIP unit, invoke commands or retrieve data, you must first access the VIP command mode. The VIP offers three different methods for activating the command mode; from a local PC that is cable connected directly to the VIP Console Port, from a remote PC that communicates with the VIP via modem, or from a remote PC that communicates with the VIP via Ethernet connection. To connect your PC to the VIP, proceed as follows: • Control via Network: Connect your 10Base-T or 100Base-T network interface to the VIP’s Network Port. • Control via Console Port: Use the supplied null modem cable to connect your PC COM port to the VIP’s Console Port. • Control via Modem: Connect your phone line to the VIP’s Modem Port. Note: The VIP features a 10Base-T, half duplex Interface. When connecting to a 100Base-T interface, most router switches will autosense to determine if the device is 100Base-T or 10Base-T, and then configure the network interface accordingly. If your router switch does not autosense, the network interface port must be manually set to 10Base-T, half duplex mode. 3-1
Page 18
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PollCat NetLink-VIP Main Menu:
Supervisor Mode
FUNCTIONS:
CONFIGURATION:
1. Status Displays 2. Buffer Functions 3. System Functions 4. System Diagnostics 5. ^Bxx Command Help 6. Recall Parameters 7. Save Parameters 8. Exit Command Mode
21. Default Parameters 22. Port Configuration 23. System Parameters 24. Scheduled Action Parameters 25. Alarm Configuration 26. Data Filter Configuration 27. FTP Push Configuration 28. FTP Server Configuration
Enter selection ...
Figure 3.1: The Main Menu
3.2.
Communicating with the VIP
The command mode can be accessed via the Console Port, network connection or Modem. Note however, that before you can communicate with the unit via network, you must first access command mode via Modem or Console Port and define certain network parameters. 3.2.1. Access via Console Port or Modem To access command mode via Console Port or Modem, proceed as follows: 1.
2.
Console Port (Local Access): This is the simplest way to access the VIP command mode. Your system communicates with the VIP via a direct cable connection to the Console Port. a)
Start your communications program (e.g., Hyperterminal or Tera Term Pro©) and press [Enter]. The VIP will respond with the "POLLCAT-NETLINK" (Password) prompt.
b)
Key in your password and press [Enter]. The default Supervisor password is "SUPER" (all uppercase, no quotes.)
Access Via Modem: Start your communications program and dial the number for the phone line that is connected to the VIP. a)
After the carrier is detected, the VIP will respond with the "POLLCAT-NETLINK" (Password) prompt.
b)
Key in your password and press [Enter]. The default Supervisor password is "SUPER" (all uppercase, no quotes.)
Note: The VIP will allow 5 attempts to enter a valid password. If a valid password is not entered in 5 attempts, the unit will disconnect. After a brief pause, the "READY" message will be sent. Press [Enter] to display the VIP Main Menu as shown in Figure 3.1. 3-2
Page 19
Quick Start Guide NETWORK PORT:
NIC Installed
COMMUNICATION SETTINGS 1. IP Address: 192.168.168.168 2. Subnet Mask: 255.255.255.0 3. Gateway Addr: (undefined) 4. SNMP Manager 1: (undefined) 5. SNMP Manager 2: (undefined) 6. SNMP Community: public 7. Reset Network 8. Send MSS: 1460 9. Send Email 10. Ping GENERAL PARAMETERS 11. Command Echo: 12. Response Type: 13. “Sure” Prompt: 14. CMD Timeout: 15. Audit Trail:
OUTPUT PARAMETERS 21. Output Mode: 22. Data on ^B01: 23. Hold End Data: 24. Line # Tag: 25. Send Compress: 26. Auto Delete:
ASCII Record On On Off Off On
OUTPUT PARAMETERS (BINARY BLOCK) 27. Transmit Att: 3 28. Transmit Delay: 5 Secs 29. DLE Stuffing: Off
On Inhibit Menu On 15 Mins Off
ACTION PARAMETERS 16. Action Delay: 10 Secs Enter selection, Press <ESC> to return to previous menu ...
Figure 3.2: The Network Parameters Menu
3.2.2. Access via Network Before you can communicate with the VIP via network, you must first access command mode via the Console Port or Modem, and set up network parameters as described below. 1.
Access Command Mode: Access the VIP command mode via Console Port or Modem as described in the previous section. When the READY message appears, press [Enter] to display the main menu.
2.
Configure the Network Port: At the Main Menu, type 22 and press [Enter] to display the Port Configuration Menu. At the Port Configuration Menu, type 6 and press [Enter] to display the Network Port Configuration menu (Figure 3.2): Note: Consult your network administrator to determine appropriate IP settings. a)
3.
IP Address: Type 1 and press [Enter]. (Default = undefined.)
b)
Subnet Mask: Type 2 and press [Enter]. (Default = 255.255.255.0)
c)
Gateway Address: Type 3 and press [Enter] (If needed.) (Default = undefined.)
Save Configuration Parameters and Exit Command Mode: Press the [Esc] key several times to return to the main menu. From the main menu, type 7 and press [Enter] to save the network parameters entered in Step 2 above. After parameters have been saved, type 8 and press [Enter] to exit from command mode. 3-3
Page 20
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
Access Command Mode via Network: Start your communications program, and then key the VIP's IP address (defined in Step 2a) into the address field. Select TCP Port 23 and then click OK or press [Enter].
4.
a)
The "POLLCAT-NETLINK" (Password) prompt will be displayed. The default Supervisor password is "SUPER" (all uppercase, no quotes.)
b)
After a brief pause, the READY message will be displayed. Press [Enter] to display the VIP main menu.
After you have successfully accessed command mode, you are then ready to connect your PBX, configure the VIP unit and begin collecting data.
3.3.
Connect your PBX to the VIP
VIP units can collect data via cable from up to three local PBX units, and can also collect data via network connection to a remote PBX unit. PollCat NetLink-VIP units provide three PBX input ports for cable connection to local PBX units, and NLJ-VIP units provide one PBX input port for cable connection to a local PBX unit. Both VIP models include one PBX IP Input port to allow data to be collected via network. • Connecting a PBX to the VIP PBX Input Port: Use an appropriate data cable to connect your PBX SMDR port to the VIP's PBX Input Port. The serial PBX Input Port is a male, DB9 connector, wired in a DTE configuration. The type of cable used will vary, depending on the configuration of your PBX. For a description of VIP’s PBX Input Port interface, please refer to Appendix B. Section 5.4.1 describes the procedure for configuring the PBX input port(s). • Connecting to a PBX via the Network Port (PBX-IP Port): Refer to your PBX user’s guide, and then configure your RSP compatible PBX to send data to the IP address for the VIP unit (defined in Step 2a in Section 3.2.2.) In the default configuration, the VIP will receive data via port number 9000. Section 5.4.6 describes the procedure for configuring the PBX IP port. This completes the Quick Start Guide for the VIP. Prior to placing the unit into operation, it is recommended to refer to the remainder of this User's Guide for complete installation, configuration and operation procedures. If you have further questions regarding the VIP unit, please contact WTI Customer Support as described in Appendix E.
3-4