PollCat NetLink-VIP & NLJ-VIP Pollable Call Accounting Terminals User's Guide, pages 31 to 40

Pages 31 to 40 of 266

The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the WTI Pollcat NetLink VIP 7173

Page 31

Configuration

5.2. Menu System Conventions 1.

Access to Submenus: All menus are key activated. To access a menu, key in the number for the desired item and press [Enter].

2.

User Level / Supervisor Level Functions: Note that most configuration menus are not available in User Mode. In order to perform the setup procedures described in this section, the Supervisor Mode must be active. The top of the Main Menu indicates whether User or Supervisor Mode is currently selected. To switch from User Mode to Supervisor Mode, select Main Menu Item 3 "System Functions". When the System Functions menu appears, select Item 1 "Security Level", and select Supervisor. Key in the Supervisor password (Default = SUPER) and press [Enter]. For more information on User functions and Supervisor functions, please refer to Appendix C.

3.

Save Parameters: After the VIP has been properly configured, it is recommended to save parameters to flash memory. If parameters are not saved, the VIP will revert to the previous configuration when power to the unit is switched off or interrupted. To save parameters, go to the Main Menu, type 7 and press [Enter].

5.2.1. Script Access to Menu Functions The VIP menu functions can also be accessed using scripts. This allows you to create polling programs that select items from command menus in order to change parameters. When writing polling software, use the following conventions: 1.

Wait for Menu: To allow the polling program to determine when a menu has been completely sent, search for the character(s) at the end of the menu. For most menus, the last three characters will be an ellipsis (three periods).

2.

Selecting Menu Items: Specify the desired menu item by number, followed by a carriage return.

3.

Moving Up One Level: To exit from a menu and return to the previous menu, send an Escape character.

5-3

Page 32

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide SYSTEM PARAMETERS: 1. Supervisor Password: 2. User Password 1: 3. User Password 2: 4. Site ID Msg: 5. Wrap-Around: 6. Real-Time-Clock: 7. Alm Data Wrap-Arnd:

(...) SMDR (undefined) (undefined) Off 06/18/2004 Fri 16:39:05 Off

Enter selection, Press <ESC> to return to previous menu ...

Figure 5.2: System Parameters Menu

5.3. Set System Parameters The System Parameters menu (Figure 5.2) is used to set common parameters, such as command mode Passwords and the Site ID Message. To access the System Parameters menu, go to the Main Menu, type 23 and press [Enter]. The following items can be configured via this menu: 1.

Supervisor Password: Defines the Supervisor password. When this password is entered at the Password Prompt, the VIP will start up in Supervisor Mode, allowing access to all menu and command functions. (Default = SUPER.)

2.

User Password 1: Defines the first User Password. When entered at the Password prompt, the VIP will start up in User Mode, allowing limited access to menu and command functions. (Default = SMDR.)

3.

User Password 2: Defines the second User Password. When entered at the Password prompt, the VIP will start up in User Mode, allowing limited access to menu and command functions. (Default = undefined.)

4.

Site ID Message: Defines a text string (up to 32 char.) that identifies the location where the unit is installed. If this item is defined, the Site ID will be displayed prior to the Command Prompt, each time command mode is accessed. The Site ID can also be displayed via the status screens (Main Menu, Item 1). (Default = undefined.) Notes: • If the Site ID message begins with an underscore (_), the message will be displayed after the command prompt. However, the underscore character will not appear when the Site ID is displayed. • If the Console Port Password is disabled (Sw7=Down), the Site ID message will not be displayed when the unit is contacted via the Console Port.

5-4

Page 33

Configuration

5.

Wrap-Around: If internal memory becomes full, the wrap-around option allows new data to be written over older data, enabling the unit to continually recycle its memory. While command mode is active, new data will not overwrite older data in the current partition. Any new data will be stored outside the top boundary. If memory is full, no additional data will be stored while command mode is active. (Default = On.) Note: When Wrap-Around is enabled and memory becomes full, there will be a noticeable delay while the unit clears old data and writes new data to flash memory. During this period, the VIP will delay response to additional commands until the wrap-around process is complete. Note that newly received data will not be lost during this delay.

6.

Real-Time Clock: Sets the VIP's internal clock and calendar. Since time dependent features (e.g. Scheduled Actions, PBX Inactivity Alarm) rely on the internal clock, it is important that the clock and calendar are accurately set.

5.

Alarm Data Wrap-Around: This feature is identical to item 6 above, except that the Alarm Data Wrap-Around only applies to data that matched a user-defined Alarm Clue. For more information on Alarms and Alarm Clues, please refer to Section 9. (Default = Off.)

5-5

Page 34

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide PORT CONFIGURATION: 1. PBX Port A 2. PBX Port B 3. Auxiliary Port 4. Console Port 5. Modem Port 6. Network Port 7. PBX IP Port Enter selection, Press <ESC> to return to previous menu ...

Figure 5.3: Port Selector Menu

5.4. Port Configuration To configure PBX Port A, PBX Port B, the AUX Port, Console Port, Modem Port or Network Port, go to the Main Menu, type 22 and press [Enter]. The Port Selector Menu (Figure 5.3), will be displayed. To select and configure ports, proceed as follows. Note that NLJ-VIP units do not include PBX Port B or the AUX Port. 5.4.1. PBX Port A and PBX Port B From the Port Selector Menu, type 1 (for PBX Port A) or 2 (for PBX Port B) and then press [Enter]. Both configuration menus include the following items: Communication Settings: 1. Baud Rate: Selects the baud rate for this port. Any standard rate from 1200 bps to 115.2K bps. (Default values are selected by SetUp Switches 4 and 5.) 2.

Bits/Parity: Selects Bits/Parity for this port; 8-None, 7-Even, 7-Odd, or 7-None. (Default = 7-Even.)

3.

Stop Bits: Selects stop bits for this port. (Default = 1.)

4.

Handshake Mode: Selects flow control for this port; XON/XOFF, RTS/CTS, both, or None. (Default = None.)

Input Parameters: 11. Time/Date Stamp: The date stamp can be inserted at the beginning of each record received by this port. This prompt is used to disable the function, or select the short format or long format. The short format (PollCat III Compatible) lists Month, Date, Hour and Minute; the long format lists Month, Date, Year, Hour, Minute, and Second. (Default = Off.) 12. Serial Number Stamp: Inserts a six digit number at the beginning of records received by this port. (Default = Off). 5-6

Page 35

Configuration PBX PORT A: COMMUNICATION SETTINGS 1. Baud Rate: 9600 2. Bits/Parity: 7-Even 3. Stop Bits: 1 4. Handshake Mode: None

INPUT PARAMETERS 11. Time/Date Stmp: Off 12. Serial No Stmp: Off 13. Strip Non-Prnt: On 14. End Character: ^J 15. Alarm Filter: Off 16. Store Alm Data: Alarm 17. Data Filter: Off 18. PBX Inact Alm: Off FIELD SUPPESSION 31. Lucent Switch

Enter selection, Press <ESC> to return to previous menu ...

Figure 5.4: PBX Port Configuration Menu (Port A Shown)

13. Strip Non-Printables: Conserves memory by excluding characters such as Nuls and Dels. (Default = On.) 14. End Character: Defines the End-of-Record (EOR) character that the VIP expects to see at the end of each record received at this port. (Default = ^J (Line Feed).) 15. Alarm Filter: Enables/disables the Alarm Filter and selects the Alarm Filter Format for this port. The Alarm Filter monitors data, and notifies the user when specific types of data are detected. For more information, please refer to Section 9. (Default = Off.) 16. Store Alarm Data: Determines where the VIP will store alarm data received via this port. Alarm Records can be stored in the Alarm File, the Standard (non-alarm) File, or both files. For more information, please refer to Section 16.1.1. (Default = Alarm.) 17. Data Filter: Enables/disables the Data Filter and selects the Data Filter Format used by this port. The Data Filter conserves memory and cuts polling time by excluding records not needed for your application. For more information, please refer to Section 8. (Default = Off.) 18. PBX Inactivity Alarm: Enables/disables the PBX Inactivity Alarm and selects the format for this port. The inactivity alarm monitors the flow of data from the PBX and notifies the user if the flow stops. For further instructions, please refer to Section 10. (Default = Off.) Field Suppression: 31. Lucent Switch: This Item can be used to suppress the phone number field in certain data records, as described in Section 5.4.1.1. This feature is useful in countries that prohibit the transfer of phone number records via network.

5-7

Page 36

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide LUCENT SWITCH: GENERAL PARAMETERS 1. Supp Number: Off 2. Supp Trunk: Off 3. Call Direction: Outgoing 4. Num Chars Supp: 4 FIELD LOCATION 11. Dest Num Loc: 12. Src Num Loc: 13. In Trunk Loc: 14. Out Trunk Loc:

16 34 46 50

FIELD LENGTH 21. Dest Num Len: 22. Src Num Len: 23. In Trunk Len: 24. Out Trunk Len:

18 12 4 4

Enter selection, Press <ESC> to return to previous menu ...

Figure 5.5: Field Suppression: The Lucent Switch Option

5.4.1.1. Field Suppression; The Lucent Switch Feature This feature is used to suppress portions of the data record that may contain phone numbers and trunk numbers, allowing HIPPA compliant data transmission. This feature is useful in situations where either local laws or regulating agencies prohibit the transmission of phone numbers. The Lucent Switch configuration menu offers the following options: General Parameters: 1. Suppress Number: When enabled, all or part of each phone number will be suppressed and not included in transmitted call records. This item can be used to select destination numbers, source numbers, both types of numbers or neither (Off.) (Default = Off.) 2.

Suppress Trunk: When enabled, all or part of trunk numbers will be suppressed and not included in transmitted call records. This item can be used to select the inbound trunk, outgoing trunk, both or neither (Off.) (Default = Off.)

3.

Call Direction: This item is used to determine if the VIP will suppress incoming phone numbers, outgoing phone numbers or both types of numbers. (Default = Outgoing.)

4.

Number of Characters Suppressed: The number of characters (starting from the right hand edge of the field) that will be suppressed. This value will be applied to both incoming calls and outgoing calls (if selected via Item 3.) (1 to 32 Characters; Default = 4.)

5-8

Page 37

Configuration

Field Location: 11. Destination Number Location: This item is used to define the beginning of the field that is normally used to store the destination phone number. (1 to 216 Characters; Default = 16.) 12. Source Number Location: Defines the beginning of the field that is normally used to store the source phone number. (1 to 216 Characters; Default = 34.) 13. Inbound Trunk Location: Defines the beginning of the field that is normally used to store the inbound trunk number. (1 to 216 Characters; Default = 46) 14. Outbound Trunk Location: Defines the beginning of the field that is normally used to store the outbound trunk location. (1 to 216 Characters; Default = 50.) Field Length: 21. Destination Number Length: This item is used to define the length of the field that is normally used to store the destination phone number. (1 to 32 Characters; Default = 18.) 22. Source Number Length: Defines the length of the field that is normally used to store the source phone number. (1 to 32 Characters; Default = 12.) 23. Inbound Trunk Length: Defines the length of the field that is normally used to store the inbound trunk number. (1 to 32 Characters; Default = 4.) 24. Outbound Trunk Length: Defines the length of the field that is normally used to store the outbound trunk number. (1 to 32 Characters; Default = 4.)

5-9

Page 38

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide AUXILIARY PORT: COMMUNICATION SETTINGS 1. Baud Rate: 9600 2. Bits/Parity: 7-Even 3. Stop Bits: 1 4. Handshake Mode: None

INPUT PARAMETERS 11. Time/Date Stmp: Off 12. Serial No Stmp: Off 13. Strip Non-Prnt: On 14. End Character: ^J 15. Alarm Filter: Off 16. Store Alm Data: Alarm 17. Data Filter: Off 18. PBX Inact Alm: Off 19. Port Mode: Store Data FIELD SUPPESSION 31. Lucent Switch

Enter selection, Press <ESC> to return to previous menu ...

Figure 5.6: Auxiliary Port Configuration Menu

5.4.2. Auxiliary Port Configuration The Auxiliary (AUX) Port can be connected to a third PBX SMDR port, or used to pass commands to a connected device. To configure the AUX Port, first go to the Port Selector Menu (Main Menu, item 22). Type 3 and press [Enter]; the AUX Port Configuration menu will appear (Figure 5.6). Note that the AUX Port is not present on NLJ-VIP units. The AUX Port Configuration menu includes the following: Note: NLJ-VIP units do not include an AUX Port. Communication Settings: 1. Baud Rate: Selects the baud rate for this port; any standard rate from 1200 bps to 115.2K bps. (Default value is selected by Set-Up Switches 4 and 5.) 2.

Bits/Parity: Selects Bits/Parity for this port; 8-None, 7-Even, 7-Odd, or 7-None. (Default = 7-Even.)

3.

Stop Bits: Selects stop bits for this port. (Default = 1.)

4.

Handshake Mode: Selects the flow control mode for this port; XON/ XOFF (Software), RTS/CTS (Hardware), both, or None. (Default = None.)

Input Parameters: 11. Time/Date Stamp: The time/date stamp can be appended to the beginning of each record received at this port. This prompt allows the user to disable the function, or select short format or long format. The short format (PollCat III Compatible) lists the Month, Date, Hour and Minute; the long format lists the Month, Date, Year, Hour, Minute, and Second. (Default = Off.)

5-10

Page 39

Configuration

12. Serial Number Stamp: Inserts a six digit serial number at the beginning of each record received by this port. (Default = Off.) 13. Strip Non-Printables: Conserves memory and cuts polling time by excluding non-printable characters (such as Nuls and Dels) from records received at this port. (Default = On.) 14. End Character: Defines the End-of-Record (EOR) character that the VIP expects to see at the end of each record received at this port. (Default = ^J (Line Feed).) 15. Alarm Filter: Enables/disables the Alarm Filter and selects the Alarm Filter used by the AUX port. The Alarm Filter can notify the user when specific types of data are detected. For more information, please refer to Section 9. (Default = Off.) 16. Store Alarm Data: Determines where the VIP will store alarm data received via this port. Alarm Records can be stored in the Alarm File, the Standard (non-alarm) File, or both files. For more information, please refer to Section 16.1.1. (Default = Alarm.) 17. Data Filter: Enables/disables the Data Filter and selects the Data Filter used by this port. For more information on the Data Filter, please refer to Section 8. (Default = Off.) 18. PBX Inactivity Alarm: Enables/disables the PBX Inactivity Alarm for this port. The PBX Inactivity Alarm monitors the flow of data from the PBX Ports and notifies the user if the flow stops. For more information, please refer to Section 10. (Default = Off.) 19. Port Mode: Selects the operating mode for the AUX Port. If the AUX Port will be connected to a PBX, the Port Mode should be set to Store Data. If the AUX Port will be used to pass commands to a connected device, the Port Mode should probably be set to Discard Data. (Default = Store Data.) Field Suppression: 31. Lucent Switch: This Item can be used to suppress the phone number field in certain data records, as described in Section 5.4.1.1. This feature is useful in countries that prohibit the transfer of phone number records via network.

5-11

Page 40

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide CONSOLE PORT: COMMUNICATION SETTINGS 1. Baud Rate: 9600 2. Bits/Parity: 8-None 3. Stop Bits: 1 4. Handshake Mode: RTS/CTS

GENERAL PARAMETERS 11. Command Echo: 12. Response Type: 13. “Sure” Prompt: 14. CMD Timeout: 15. Audit Trail:

OUTPUT PARAMETERS 21. Output Mode: 22. Data on ^B01: 23. Hold End Data: 24. Line # Tag: 25. Send Compress: 26. Auto Delete:

ASCII Record On On Off Off Off

OUTPUT PARAMETERS (BINARY BLOCK) 27. Transmit Att: 3 28. Transmit Delay: 5 Secs 29. DLE Stuffing: Off On Inhibit Menu On 15 Mins Off

ACTION PARAMETERS 16. Action Delay: 10 Secs Enter selection, Press <ESC> to return to previous menu ...

Figure 5.7: Console Port Configuration

5.4.3. Console Port Configuration The Console Port is used for connection to a local control device, such as a PC or terminal. To configure the Console Port, first go to the Port Selector Menu (Main Menu, item 22). Type 4 and press [Enter]. The Console Port Configuration Menu (Figure 5.7) will be displayed. The following options are available: Communication Settings: 1. Baud Rate: Selects the baud rate for this port; any standard rate from 1200 bps to 115.2K bps. (Default value is selected by Set-Up Switches 1, 2, and 3.) 2.

Bits/Parity: Selects Bits/Parity for this port; 8-None, 7-Even, 7-Odd, or 7-None. (Default = 8-None.)

3.

Stop Bits: Selects stop bits for this port. (Default = 1.)

4.

Handshake Mode: Selects the flow control mode for this port; XON/ XOFF (Software), RTS/CTS (Hardware), both, or None. (Default = RTS/CTS.)

General Parameters: 11. Command Echo: Enables / Disables the command echo for this port. During set-up, it may be helpful to enable the command echo. This allows keystrokes sent to the VIP unit to be displayed on your monitor. (Default = On.)

5-12