Page 51
Click on any of the tabs to change settings for that section. Once you have made your changes, click OK and the changes are automatically made in your TriCoder.
Cloning from one TriCoder to another If your programs, tables and setup are complex or large, transmitting them from TriCoder to TriCoder is faster and easier than manually entering all of the information every time. Transmitting programs and setup to a host computer allows you to store a back-up copy (excluding Voice Messages) available for download if anything happens to your TriCoder. Transferring programs, tables and setup directly from one TriCoder to another is called Cloning. Cloning also allows you to copy voice messages from one TriCoder to another (transferring programs and setup to the host computer does not allow you to do this). There are several things you need to do before receiving programs or setup from another TriCoder:
•
Receiving and transmitting programs from one TriCoder to another requires the correct cables. The TriCoder Data Cloning Cable (F38) is needed to clone or transmit/receive programs, tables and setup information. The TriCoder Voice Cloning Cable (T15) is required to "clone" or transmit and receive voice messages. Voice messages can only be transmitted or received from TriCoder to TriCoder. They cannot be transmitted via host computer. The Data Cloning Cable is attached to each TriCoders Computer port. The connector on the Voice Cloning Cable that has two black rings on the tip plugs into the auxiliary jack on the bottom of the receiving TriCoder. The tip with the single ring plugs into the transmitting TriCoder.
•
Make sure all data is uploaded and deleted from the receiving TriCoder. The TriCoder will not allow you to receive data unless the TriCoders data files are empty.
•
Plug in the 5-volt power adapter(s). You want to make sure you don’t have a low-battery situation in the middle of a transfer.
•
For serial and keyboard cloning, always start the receiving TriCoder first. For USB cloning to a host computer, follow the instructions on the TriCoder’s display.
•
When transmitting between two TriCoders, both TriCoders must be configured to use the same Computer Interface. If configured as serial interface, the serial parameters must be the same on both TriCoders; baud rate, parity, data bits and stop bits must match. Two USB TriCoders cannot be cloned together.
6-4
Page 52
Starting the Receiving TriCoder Make sure all cables are attached correctly and the 5-volt power adapter is plugged in. To start the receiving TriCoder, answer NO to all prompts until you see: PROGRAM RECEIVE? KEY [YES/NO]?_ Press YES to get to the RECEIVE PROGRAM menu: RECEIVE PROGRAM KEY ------------------------------ -------Programs [1-3]?---------->1 - 3 Clone TriCoder?----------> 0 Press 0 to Clone the entire TriCoder. Cloning receives the programs, tables, Setup, and voice messages (if using a voice cloning cable T15) from another TriCoder. Press 1, 2 or 3 to receive a program only. Pressing 1, 2 or 3 determines which program number you are assigning - it does not have to correspond to the program number being transmitted from the other TriCoder or host. After making a selection, the TriCoder displays: RECEIVING PROGRAM PLEASE Once the transmission is complete, the receiving TriCoder displays: END OF PGM. RECV HIT ANY KEY_ Press any key to return to the Mode Menu. If the TriCoder has a problem during the transmission, the transfer will end and the TriCoder will display the following error message: DATA XMIT ERROR CYCLE POWER If you receive this message while receiving a program, the program transfer is incomplete and the transmit/receive session will have to be restarted. To avoid any problems, do not press any keys on the TriCoder once the transmission has started.
6-5
Page 53
Starting the Transmitting TriCoder At this point, you can start the transmitting TriCoder. To start transmitting programs or setup from a TriCoder, answer NO to all prompts until you see: PROGRAM TRANSMIT? KEY [YES/NO]?_ Press YES to get to the TRANSMIT PROGRAM menu: TRANSMIT PROGRAM KEY -------------------------------- -----Programs [1-3]?------------>1 - 3 Clone TriCoder?------------> 0 Press 0 to Clone the entire TriCoder. Cloning transmits the programs, tables, Setup and voice messages (if using a voice cloning cable T15) to another TriCoder. Press 1, 2 or 3 to transmit a program only. Pressing 1, 2 or 3 determines which program number you are transmitting - it does not have to correspond to the program number chosen by the receiving TriCoder or host. After making a selection, the TriCoder displays: SENDING PROGRAM PLEASE Once the transmission is complete, the transmitting TriCoder displays: END OF PGM. XMIT HIT ANY KEY_ Press any key to return to the Mode Menu. The serial protocol for program transmission is different than that for data transmission. During serial program transmission, the TriCoder transmits each character one at a time, expecting the receiving TriCoder to echo the character back. If the characters match, then the transmitting TriCoder sends the next character. If the characters don’t match, the transmitting TriCoder sends a NAK to the receiving unit. At that point, the transmitter re-sends the last character. If the transmitter ends up sending 10 NAKS, it will abort the transmission (there is obviously something wrong) by sending EOT (ASCII 4) and display the following error message: DATA XMIT ERROR CYCLE POWER
6-6
Page 54
If all data is echoed back correctly, the last character sent to the receiving unit is ASCII 128. If you see this message while transmitting a program, the program transfer is incomplete and the transmit/receive session will have to be restarted. To avoid any problems, do not press any keys on the TriCoder once the transmission has started.
6-7
Page 55
TriCoder Setup Parameters Default settings are shown in bold print. The number or letter associated with the setting is the same whether configuring the TriCoder using the bar coded Setup Menu or via the keypad in PROGRAMMING MODE. Some parameters are set only by the bar code setup menu or only by the TriCoder keypad.
Beep Tone Lowest Low Medium High Highest No Beep, No LED on tethered scanner No Beep, but LED on tethered scanner shows good read
0 1 2 3 4 5 6
The TriCoder allows five different beep pitches or no beep at all.
Speaker Volume Speaker and beeper volume are also controlled by keyboard Setup in PROGRAMMING MODE. The default is 5, a medium setting. If you want it louder, enter a larger number. If you want it less loud, enter a lower number.
Code 3 of 9 (Code 39) Enable Code 3 of 9 Disable Code 3 of 9 Enable Full ASCII Code 39 Disable Full ASCII Code 39 Enable Code 39 Accumulate Mode Disable Code 39 Accumulate Mode Enable Start/Stop character transmission Disable Start/Stop character transmission Enable Mod 43 Check Digit Disable Mod43 Check Digit Enable Check Digit transmission Disable Check Digit transmission Caps Lock ON Caps Lock OFF
0 1 2 3 4 5 6 7 8 9 A B C D
• The Start and Stop character for Code 39 is the * character. Settings 6 and 7 determine whether or not those characters are transmitted to the computer along with the data. For example, at setting 6, the data of 1234 would be transmitted as *1234*. Transmitting the start and stop 6-8
Page 56
characters can be useful if you need to differentiate between data that comes from a bar code versus data coming from the keyboard.
• Enabling use of the Mod 43 check character requires that the last character of your bar code conform to the Mod 43 check character specifications. See Appendix H; Code 39 for more information. Enable transmission (A) will send the check digit data along with the rest of the bar code data to your computer. To use A, you must also be using 8.
• Caps Lock ON causes lower case letters read as data to be transmitted to the computer as UPPER CASE, and upper case letters to be transmitted as LOWER CASE. Numbers, punctuation and control characters are not affected. This setting applies to all bar code types.
UPC/EAN Enable UPC/EAN Disable UPC/EAN Enable UPC/EAN Supplements Disable UPC/EAN Supplements Enable transmission of UPC-A NSC or EAN 2 Flags Disable transmission of UPC-A NSC or EAN 2 Flags Enable transmission of UPC-A and EAN-13 check digit Disable transmission of UPC-A and EAN-13 check digit Enable transmission of UPC-E NSC and EAN-8 Flag character Disable transmission of UPC-E and EAN-8 Flag ch. Enable transmission of UPC-E and EAN-8 Check digit Disable transmission of UPC-E and EAN-8 check digit UPC-E Compressed UPC-E Expanded EAN-8 observing 9&A EAN-8 forced to transmit 8 digits always
0 1 2 3 4 5 6 7 8 9 A B C D E F
• Use setting 2 to enable reading of the 2 and 5 digit UPC/EAN supplements commonly found on magazines and paperback books. Using this setting forces left to right reading of UPC codes to assure that the supplement code is not missed. This setting also allows for reading of the UCC/EAN 128 Extended Coupon Code. The Extended Coupon Code consists of a UPC code with a NSC of 5 or and EAN code with a country code of 99 along with a C0de 128 supplemental code to the right. This setting allows you to read the Code 128 supplement with the UPC/EAN, providing the UPC has a NSC of 5 or the EAN code has a country code of 99. Without the correct NSC or country code, the Code 128 portion will be ignored; UPC code with an NSC of 5 or EAN codes with country code of 99 will not be read unless there is a readable Code 128 supplemental code read also. 6-9
Page 57
• ISBN (International Standard Book Numbering) bar codes are EAN-13 with a 5-digit supplement. If the “Bookland” bar code uses 978 (books) or 977 (periodicals) as the first three digits, then it can be transmitted by the TriCoder in the ISBN format. The settings for this can be found under the Terminator Character parameter. For details on ISBN, see Appendix K; UPC/EAN. • Use setting 4 and 9 to enable transmission of the NSC character to your computer. The Number System Character is the leading character in the bar code. For details, see Appendix K; UPC/EAN. • Use setting 6 and A to enable transmission of the check digit character to your computer. The check digit is the last character and is based upon a calculation performed on the other characters. • Setting C transmits UPC-E0 bar codes as is; setting D transmits them with inserted zero’s to make them the same length as a UPC-A bar code. A NSC of 0 is assumed. It is possible to read UPC-E1 bar codes; by default this option is disabled. Do not enable UPC-E1 if you plan on reading EAN-13 bar codes; you may experience partial reads when reading EAN-13. The UPC-E1 option is set in the 2 of 5 Code parameter. To enable UPC-E1 reading, set the 2 of 5 Code parameter to 8. To turn off UPC-E1 reading, set it back to the default of 9. • If you prefer to transmit UPC-E bar codes in a 6 digit format while EAN-8 is transmitted in its original 8 digit format, use setting F. This will allow you to use settings 9 and A and still transmit EAN-8 as 8 digits. • UPC-A can be transmitted in EAN-13 format by adding a leading 0 (USA county code) to the UPC-A data. This setting is found in the Terminator Character parameter.
Codabar Enable Codabar Disable Codabar Enable CLSI Codabar Disable CLSI Codabar Disable Start/Stop character transmission Enable Start/Stop character transmission
0 1 2 3 4 5
• CLSI is a form of Codabar often used by libraries. • Setting 5 will transmit the Codabar start and stop characters with the bar code data to your computer. If you are varying the start and stop characters to differentiate between different labels, transmitting the start and stop can be helpful. See Appendix L; Codabar for more information. 6-10
Page 58
2 of 5 Code Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 check digit Disable Interleaved 2 of 5 check digit Enable check digit transmission Disable check digit transmission Enable Standard 2 of 5 Disable Standard 2 of 5 Enable UPC- E1 Disable UPC- E1
0 1 2 3 4 5 6 7 8 9
• Setting 2 requires that the last digit in your bar code conform to the specifications for the 2 of 5 check digit calculation. See Appendix J; 2 of 5 Code for more information. • Transmission of the check digit (5) requires the use of setting 2 and will transmit the check digit along with the bar code data to the computer. • Settings 8 and 9 enable and disable the reading of UPC-E1 codes. See the UPC/EAN setup parameter for more information.
2 of 5 Length Default setting Valid entries To read variable length 2 of 5 codes (temporarily ONLY!)
06 00-98 00
• 2 of 5 codes are so susceptible to partial misreads that only one length of code should be read, and that should be checked by the TriCoder. • The default setting of 06 causes the TriCoder to read only 2 of 5 codes that are 6 digits in length. To set the TriCoder to read a different length, scan any two digit number from the bar pad table. For example, to change the TriCoder to accept an 8-digit bar code, scan 0 then 8 from the bar pad table. 2 of 5 code must always be an even number of digits so the length setting must always be an even number. • If you have to read variable length Interleaved 2 of 5 codes, specify a 2 of 5 length of 00, however, you will want to use other checking features (Data ID, etc.) when creating a program for data collection. Reading variable length I 2of5 or 2 of 5 codes is to be avoided if at all possible. The 00 setting is supplied for the purposes of reading codes of unknown length, counting the digits, and setting the length to the proper number.
6-11
Page 59
MSI/Plessey Disable MSI & Plessey bar codes Enable MSI, 1 Mod 10 check digit Enable MSI, 2 Mod 10 check digits Enable MSI, 1 Mod 11/ Mod 10 check digit Transmit no check digits Transmit 1 check digit Transmit 2 check digits Enable Plessey bar code (mutually exclusive with MSI) Enable LabelCode5 (mutually exclusive with MSI & Plessey) Enable LabelCode4 (mutually exclusive with all above codes)
0 1 2 3 4 5 6 7 8 9
• LabelCode 5 and LabelCode 4 are proprietary bar code types used by Follet. • For more information regarding MSI or Plessey Code, see Appendix M; MSI Plessey Code.
Code 128 Disable Code 128 Enable Code 128 Disable UCC/EAN-128 Enable UCC/EAN-128 Enable Storage Tek Tape Label Code (TriOptic Code 39) Disable Storage Tek Tape Label Code (TriOptic Code 39) Bar Code ID’s transmitted Bar Code ID’s not transmitted
0 1 2 3 C D E F
• UCC/EAN-128 is a subset of Code 128 that follows certain specifications regarding character content, length and check digits. Enabling UCC/EAN-128 (2) causes the TriCoder to look for a Code 128 bar code that begins with the Code 128 F1 (Function 1) character. See Appendix I; Code 128 for more details. • The StorageTek Tape Label code (also called TriOptic Code 39) is a proprietary variation of Code 39 code used for the storage of computer data tapes. Enabling the tape label code (C) does not disable reading of Code 128 bar codes. • Bar Code ID’s are characters assigned to each bar code type to identify that particular type of code. These Bar Code ID’s can be used to identify what type of bar code you are using when you are not sure or you want your application to differentiate between the different types. This applies only when the TriCoder is used in NON PORTABLE mode.
6-12
Page 60
The Bar Code ID’s are assigned as follows: Bar Code Codabar UPC-A I 2of5 Code 128 MSI UPC-E (1) StorageTek LabelCode 4
ID a c e g j o s y
Bar Code Code 39 EAN-13 2 of 5 Code 93 UPC-E(0) EAN-8 Plessey LabelCode 5
ID b d f i n p x z
The ID character is transmitted in front of the bar code data.
Code 93 Enable Code 93 Disable Code 93 Enable Full ASCII Code 93 Disable Full ASCII Code 93
0 1 2 3
• Code 93 is similar in character set to Code 39. See Appendix N: Code 93 for more information. Code 93 is not a commonly used bar code symbology.
Preamble and Postamble The Preamble and Postamble apply to data entered in NON-PORTABLE MODE only. Upload Prefixes are used in programs for portable data collection. • Preambles are user-defined data that is transmitted at the beginning of data (bar code or keyed) that is entered in the TriCoder in NON PORTABLE mode. For example, if you set a preamble of @@ and scanned bar code data of 12345, @@12345 would be transmitted to the computer. • Postambles are user-defined data that is transmitted at the end of data (bar code or keyed) that is entered in the TriCoder in NON PORTABLE mode. For example, if you set a preamble of @@ and scanned bar code data of 12345, 12345@@ would be transmitted to the computer. • By default, the TriCoder has no preambles or postambles configured. Preambles and Postambles can each contain up to 15 characters scanned from the bar coded FULL ASCII Menu. To set a preamble or postamble: