Page 61

1.

Scan the Preamble or Postamble bar code or select Preamble or Postamble from the keypad menu.

2.

Scan the desired characters (up to 15) from the FULL ASCII Menu.

3.

Scan the SET bar code, or if using the keypad, press ENTER.

4.

To clear the Preamble or Postamble and return to the default (no Preambles or Postambles defined), scan CLEAR at step #2, then continue with your setup.

• You can use the Preamble or Postamble to trim characters from the data you are entering into the TriCoder in NON PORTABLE mode. The Upload Prefix and Suffix is used to trim data in portable mode (data collection). You can trim from 1-15 characters from the data by creating a preamble or postamble of: ~x where ~ is ASCII 126 and x is a single hex digit 1-F (corresponding to 1-15). Data that is shorter than the trim amount are transmitted without trimming. Preambles trim data from the front; Postambles trim characters from the end. Here are some examples, with and without trimming included: Data Scanned

Preamble Value

Data Transmitted

123 12345678 12345678 12345678901 123456

XYZ ~3XYZ ~9 ~A ~5

XYZ123 XYZ45678 12345678 1 6

Preamble affects leading (high order) characters Data Scanned

123 12345678 12345678 12345678901 123456

Postamble Value

Data Transmitted

XYZ ~3XYZ ~9 ~A ~5

123XYZ 12345XYZ 12345678 1 1

Postamble affects trailing (low order) characters • Using the Bar Code ID feature and the Preamble or Postamble, you can trim data selectively, trimming characters only on the bar code type specified. To use selective trimming, enter: ~bx where b is the Bar Code ID character (see the Code 128 setup parameter) and x is the number of characters to trim from the front of the data. For example, ~b2~c1 says “trim 2 characters 6-14

Page 62

from Code 39 data and 1 character from UPC-A data”. Remember that the Preamble trims leading data and the Postamble trims trailing data. • The Preamble and Postamble can also be used to create “line feeds” on the TriCoder display before the data is displayed. To enter “line feeds” before or after your data enter: }x where x is 1-3, depending on how may lines you want to scroll. For example, it you wanted skip 3 lines, you would enter }3. • Lastly, the Preamble and Postamble can be used to check a minimum and maximum character length for data entered in NON PORTABLE mode. In portable data collection, min and max character lengths are set using the Max Data Len and the Min Data Len in the programming statements. To check for length in the Preamble or Postamble, enter: |nnmm where | is ASCII 124, nn is the two-digit minimum and mm is the two-digit maximum. |0210 would check for a minimum of 2 characters and a maximum of 10.

Terminator Character CR - Carriage Return HT - Horizontal Tab None CR/LF - Carriage Return/Line Feed Do not transmit EAN-13 data with 5 digit supplement as ISBN Transmit EAN-13 data with 5 digit supplement as ISBN format No country code transmitted for UPC-A Transmit UPC-A in EAN-13 format (Country Code 0)

0 1 2 3 C D E F

• The Terminator Character is the character sent at the end of each data entry in NON PORTABLE mode and at the end of each field when uploading after data collection (Portable use). Your application will determine what Terminator Character (if any) you use. • In Keyboard Wedge mode, CR (0) is the default. For Serial Interface, CR/LF (3) is the default. • Settings C, D, E and F correspond to settings for UPC bar codes only. See the UPC/EAN section for details.

6-15

Page 63

Computer Interface PC USB Keyboard Upload PC compatibles Keyboard Wedge RS-232 ASCII Data Format RS-422 ASCII Data Format PC USB High Speed Upload If setting 1 or setting 2 and Non-Dedicated Server Learning Mode for Timing with PC Keyboard Wedge Macintosh USB Keyboard

0 1 3 5 6 7 8 9

T64/LT64s are shipped with the Computer Interface set to 1. T54s/LT54s are shipped with the Computer Interface set to 3. All models of the TriCoder have a built-in USB port.

USB Selections If you have a Mac, you must choose 9. You are limited to Non-Portable Mode and Data Upload as a Mac USB Keyboard. If you are using Windows-98 or later (2000, ME, XP, etc.) and you wish to upload your files directly into your application through the keyboard, you must choose 0, (USB keyboards are still superior to keyboard wedge because there are no timing delays and no jumper block is necessary). After specifying 2, the first time you plug in a USB cable to the TriCoder and host, you will be asked to install the USB Keyboard HID driver, which is probably on your hard disk, but if not, is on your original Windows CD ROM; just keep clicking on NEXT until you are forced to supply the original Windows CD ROM. Data uploads through the keyboard will be slower than serial and high speed USB, but you will still be able to use the High Speed program uploads/downloads, firmware upgrades, and table downloads; the first time you attempt a high speed USB operation, you will be required to install another driver for high speed support, TRICODERUSB, which is supplied on your TriCoder Utilities CD ROM, (also on our website, www.barcodehq.com under Downloads). If you are using Windows and you wish to use the TriCoder Utilities to upload data to a file in high speed, choose 6. You will also be able to do program uploads/downloads, firmware upgrades, and table downloads. The first time you plug in a USB cable between the TriCoder and a host, you will be required to install the high speed TRICODERUSB driver that is supplied on your TriCoder Utilities CD ROM, (also on our website, www.barcodehq.com under Downloads). The first time you attempt to use Non-Portable Mode, you will be asked to install the USB Keyboard HID driver, which is probably on your hard disk, but if not, is on your original Windows CD ROM.

6-16

Page 64

Other Interfaces Depending upon the setting of the Interface Jumper (see pages K-2 and K3), the TriCoders Computer Interface is set to either RS-232 or PC compatible Keyboard Wedge. • The easy way to select an interface if using Keyboard Wedge mode (not USB) is to use Learning Mode (8). Follow these instructions: 1. 2. 3. 4. 5.

Scan Start Setup Scan Computer Interface Scan 8 Press any key on your PC keyboard Scan End Setup

The TriCoder watches the key codes coming from the computer, “learns” the keyboard timing, and beeps to signify it has captured the timing; it then sets it in the EEPROM until you change it. • RS-422 is for use with RS-422 boards only. If your computer is using a RS-422 board, you must order the 422 option at the same time you order your TriCoder, as this feature is not field-installable. RS-422 also requires special cables. RS-422 and RS-232 are mutually exclusive; only one or the other is available. • If you are a Windows user with Window 98, 2000, ME, XP, or later, we suggest that you use the high speed USB interface, which offers the following advantages: (the first time you plug in your USB cable, you may be asked to choose the type of USB interface you wish to use) 1) Data uploads at speeds 40 times faster than a serial upload. 2) The ability to update your firmware at speeds 40 times faster than serial interface (its not even possible with the keyboard wedge). This includes all improvements available on our Website for the life of your TriCoder. 3) The ability to download tables and upload/download programs from your PC at much faster speeds than serial, (not possible with keyboard wedge interfaces) and use the TriCoder Utilities to quickly change your TriCoder Setup. 4) The ability to operate in Non-Portable Mode as a USB keyboard without having to add a jumper block to a Y-Cable when the TriCoder is removed from the Y-cable for portable data collection.

6-17

Page 65

Intercharacter Delay None Short Delay Medium-short Delay Medium-long Delay Long Delay

0 1 2 3 4

(This does not apply to USB. It rarely applies to serial.) • Use Computer Interface setting 8 for Learning Mode whenever possible. This allows the TriCoder to figure out the timing on its own and set it in the EEPROM for you. Don’t try this parameter unless Learning Mode fails. • Intercharacter Delay is a setting that allows the TriCoder to match the keyboard timing on your PC. Most computers work fine with no delay at all, but due to the variety of BIOS and clock speeds, some PC’s may need a timing delay. • The best way to determine whether you need to program a delay or not is to start at setting 0 (None). Try reading a bar code in NON PORTABLE mode while connected to your computer. If your data transmits with no problems, leave your delay at 0. If you have garbled or missing data, try each delay starting with 1 until you have complete and correct data. Between setting changes, try typing on your keyboard to make sure you still have correct characters coming from your keyboard. In some instances, you may need to re-boot the computer between delay setting changes. • Intercharacter Delay settings are generally for Keyboard Wedge mode but will work in Serial Mode (usually only if using PortKey and emulating keyboard data). Garbled data in Serial Mode is usually the result of the wrong Baud Rate or Parity setting. Check these first before you start changing the Intercharacter Delay.

Speaker / Batteries Speaker ON Speaker OFF Alkaline Batteries or Alkaline Rechargeables Nickel Metal Hydride or NiCad Rechargeable Batteries

0 1 2 3

• If you are using the headphones in a noisy environment, you can conserve battery power by turning the Speaker OFF (1). You control the volume of the headphones by adjusting a variable resistor inside the TriCoder’s case. See Appendix F: Jumpers, Switches, and Adjustments.

6-18

Page 66

• For the TriCoder to know when to tell you to change batteries, you must select the correct battery type. The default is Alkaline (2). If you start using rechargeable batteries and fail change 2 to 3, your TriCoder will probably start acting very strange, (beeping, black bars on the display, no laser beam, etc.) as the batteries run down. Rechargeable batteries don’t have the instant reserve power that alkalines do; therefore, without warning or indication they can be depleted unless the TriCoder knows to look for rechargeable batteries. Battery Status can be displayed by pressing the STATUS key on the TriCoder keypad while in NON PORTABLE mode or while collecting data (portable).

Scanner Options Switch Wand (no longer available) Non-switched Wand (for NON PORTABLE mode only)

7 8

If using a "switch" wand (no longer available), you must set the decode light switch to "W", (See Appendix F). A “non-switched” wand can be used, but only with the 5v power supply and the decode light switch (see TriCoder diagram in Appendix F) must also be set to "L", (the default at shipping).

Aiming Dot Duration If you have a DMA TriCoder with firmware version of DMA2018 or higher, board level F or greater, and an internal laser or the external LZ200D scanner, you can get a aiming dot to project before the laser beam spreads over the bar code. This is useful when trying to read in direct sunlight (because the dot is brighter than the line), when trying to read at a distance, and when trying to read one of many bar codes on a page. By setting the time in 1/10ths of a second that the aiming dot stays on after pulling the trigger and before the beam spreads, the bright dot can be used to position in the middle of the bar code. This feature is accessible only through the keyboard setup under OTHER. The default is set to 00, no aiming dot. You can enter any number from 01 to 99 (99 gives 9.9 seconds). Typically you will want 1 (10) or 2 (20) seconds of aiming dot. You also must make sure the decode light switch (see diagram on page M-3) is set to L. To check your firmware version and board level, power up your TriCoder and note the opening screen display: DMA TRICODER Xxxxx B HIT ANY KEY_

6-19

Page 67

X is

W for a TriCoder jumpered for Keyboard Interface or R for a TriCoder jumpered for Serial Interface or K for USB Keyboard upload or H for USB High Speed upload xxxx is the firmware version (i.e. 2018) and

B is the board level( i.e. F).

Keyboard Country US French German Belgian French Canadian Danish Dutch Italian Latin American Norwegian Portuguese Spanish Swedish Swiss German United Kingdom

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14

• This does not apply to USB or Serial. In addition to keyboard wedge country emulation, it also controls the display of French, German, or English messages. • This parameter applies only to TriCoders operating in Keyboard Wedge mode. The default setting is US (00) and requires a two-digit entry for all settings. • Setting 01 (French) and 02 (German) also apply to the displayed messages on the TriCoder. Displayed messages will appear on the TriCoder in the language chosen. If you want to use a US keyboard and display messages in French or German, scan 51 for French or 52 for German.

6-20

Page 68

Operation Mode Non Portable Mode Programming Mode Data Collection Mode Data Upload Mode Program Transmit Mode Program Receive Mode Buffered Terminal Mode

0 1 2 3 4 5 6

• Non Portable Mode is used to read data directly into the Computer from the TriCoder, both in Keyboard Wedge, USB and Serial modes. If using the TriCoder as a serial interface, setting Protocol to Host Response Accepted can turn the TriCoder into a dumb terminal, displaying prompts from the host and transmitting data back. • Programming Mode is used to create or modify a program, record and test voice prompts and to change the Setup using the TriCoder keypad. The TriCoder requires entry of a password before you are allowed to access Programming Mode. The password, WDTRI, is the same for all TriCoders. • Data Collection Mode is a portable mode used to collect data using one of the TriCoder's four available programs. Program #0 and Program #1 are pre-programmed into the TriCoder when you receive it. Program #0 is a fixed program while Program #1 is a simple inventory program that is user-editable. Programs #2 and #3 are not set and are available for custom programming. See Chapter 1 and Chapter 2 for data collection tutorials using Program #0 and #1. • Data Upload Mode is used to transfer data collected in the TriCoder to the host computer for Keyboard Wedge, USB and Serial mode. • Program Transmit Mode is used to transmit a TriCoder program, setup or voice messages to another TriCoder or to a host computer. Voice messages can only be transferred from TriCoder to TriCoder. “Cloning” (copying the entire setup and programs) is handy when setting up multiple TriCoders. • Program Receive Mode is used to receive a TriCoder program, setup or voice messages from another TriCoder or host computer. Voice messages can only be received from another TriCoder. • Buffered Terminal Mode allows the TriCoder to function as an online intelligent buffered terminal using Program #1 and uploading upon request by a host computer polling with ACK/NAK protocol. This mode requires programming at the computer end.

6-21

Page 69

Voice Messages This parameter partitions the total amount of voice messages into different message lengths. The default setting is: 303015 xx yy zz where: xx is number of ½ second messages yy is the number of 1 second messages zz is the number of 2 second messages The total time allotted must not exceed 75 seconds. To change the partitions, scan 6 digits total; 2 for the number of ½ second messages, 2 for the number of 1 second messages and 2 for the number of 2 second messages. See the default setting as an example. WARNING: changing this parameter after you have recorded messages could result in having to re-record some of them; they would still be there but longer messages may get cut up and shorter ones combined.

Set Date Using the barpad table, scan a 6-digit date in the mmddyy format. For example, to set a date of 1/1/99, you would scan 010199. Press the STATUS key to view the current date and time in both NON PORTABLE mode and during data collection. To set the time in the TriCoder from a host computer, see Appendix U; Using the TriCoder as a Time Clock for details. There are alternative date formats available for the TriCoder. See the Protocol parameter for details. Changing the date format requires resetting the actual date in that format also. If you setup the TriCoder using the keypad in PROGRAMMING MODE, you can choose to have the TriCoder display the year in a 4-digit format instead of a 2-digit format. This setting will help you comply with Y2K requirements.

Set Time Using the barpad table, scan a 4-digit time in the military hhmm format. For example, to enter a time of 3:35 p.m., scan 1535. Press the STATUS key in NON PORTABLE mode or during data collection to view the current time. The time can also be set from a host computer; see Appendix U; Using the TriCoder as a Time Clock for details. Batteries maintain the real-time clock. Fresh batteries will keep your realtime clock as accurate as possible. 6-22

Page 70

Alternative Date and Time formats See the Protocol parameter for details on how to set the TriCoder to use alternative Date and Time formats. The default formats use mmddyy and hhmm. Formats include: • • • •

A - short format - no separators between characters B - long format - date uses / separators, time uses: separator C - US format - mmddyy, hhmm D - European Format- ddmmyy, hhmm

Combinations are AC, AD, BC and BD. To use the European format, first change the format in the Protocol parameter, then reset the date and time, entering the digits in the correct order. Follow the same procedure to set it back to the US format.

Single Cycle Transmit Single Cycle Transmit OFF Single Cycle Transmit ON

0 1

• Single Cycle Transmit allows the TriCoder to upload one field at a time to the host, controlled by the pressing of any key (except F1) on the TriCoder each time the operator wants to transmit a field. • Single Cycle Transmit is used to test complex upload prefix and suffix sequences. This is typically used when a TriCoder is used in Keyboard Wedge mode and you are uploading directly into an application. Single Cycle Transmit allows you to test key sequences and delays before you collect a lot of data and try an upload. Pressing F1 terminates the upload session.

EOF String The EOF String setting allows you to choose up to 8 characters to be transmitted at the end of a TriCoder file upload. It is typically used to signal to the receiving host program that the TriCoder is done uploading its data and has transferred its last piece of data. The characters chosen are often characters not available on the TriCoder keypad; they are scanned from the FULL ASCII MENU. To program an EOF String: • Scan EOF String • Scan up to 8 characters from the FULL ASCII MENU • Scan the SET bar code If you do not program an EOF String, the TriCoder sends a Ctrl Z (ASCII 26). Undisplayable characters are displayed on the TriCoder as ?. To view the ASCII equivalent (so you know what characters are there) press the F2 key while in the EOF String parameter. 6-23