The text of a manual · part 5 of 26
TriCoder Users Manual, pages 41 to 50
Pages 41 to 50 of 246
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Worth Tricoder T61, Worth Tricoder T62, Worth Tricoder T63, Worth TriCoder LT63, Worth Tricoder T50, Worth TriCoder T52 and Worth TriCoder T53
Page 41
Serial Installation on PC
Serial Interface Communications Software If you serially connect the TriCoder to a PC, software is required to communicate with the serial port. Some applications read the serial port directly; no additional software is required. If you want to connect to the serial port yet emulate the keyboard, use our PortKey software. PortKey takes data coming from the serial port and redirects it through the keyboard buffer, allowing you to emulate most keys on your keyboard. PortKey has its own users manual. Follow the manual for installation and setup instructions. The TriCoder comes with the TriCoder Utilities for Windows that allows you to configure your serial port, test your communications, upload data and programs, download programs and tables and edit tables. The Windows TriCoder Utilities is the easiest way to test communications. If you are using a program other than the TriCoder Utilities, follow the installation and setup instructions for that program.
Configuring the TriCoder Once the hardware is connected, the next step is to configure the TriCoder and test your communication. If you are using the serial interface, you should have installed the serial communication software you want to use (see the previous section). The TriCoder setup allows the user to configure the TriCoder for different computer interfaces, and reading of different types of bar codes, as well as configuring some of the more advanced features of the TriCoder. The TriCoder can be setup using the bar coded setup menu or by going into PROGRAMMING MODE.
5-4
Page 42
Using the bar coded TriCoder Setup Menu To use the bar coded TriCoder Setup Menu, scan these bar codes in this order:
• • •
Start Setup Setup Parameter bar code (i.e. “Beep Tone”) Bar code of number that corresponds to the appropriate setting (i.e. 3 to change the Beep Tone to “high”) • End Setup More than one Setup Parameter can be changed before you scan END SETUP. For example, scan START SETUP, then “Beep Tone”, then 3, then “Operation Mode”, then 0, then END SETUP. This series of scans changes the beep tone to “high”, and puts the TriCoder into NON PORTABLE mode. For details on TriCoder Setup Parameters, see Chapter 6; TriCoder Setup.
Using Programming Mode to change the TriCoder Setup The same Setup Parameters can be changed using the TriCoder keypad (no bar codes necessary) by going into PROGRAMMING MODE. Answer NO to all of the prompts until you see: PROGRAMMING MODE KEY [YES/NO]?_ Press the YES key; then enter the password, WDTRI. At the menu prompt, press the 5 key to CHANGE SETUP. Once in the TriCoder Setup, press the number of the group you want to enter. Press ENTER until you see the Setup Parameter you want to change (i.e. BEEP TONE), then enter the number for the correct setting (i.e. 3 to change the BEEP TONE to “high”). More than one Setup Parameter can be changed before you exit the setup. Pressing F1 while in a Setup Parameter will take you back to the Setup Menu; from there choose a new group of settings. Pressing F1 again at the Setup Menu will exit PROGRAMMING MODE.
PC Serial Interface The Serial Interface requires certain setup parameters. To set up the TriCoder, you need to know some basic information about the serial port you will be using, as well as the software you will use to test the TriCoder. If possible, use the TriCoder at its default settings. Whether or not you can do this often depends upon the software you are using. If using PortKey or the TriCoder Utilities, use the default settings. If your software requires you to set your own baud rate, parity, data bits and stop bits; simply set them to match the TriCoders default settings. See Chapter 6; TriCoder Setup for details on changing the serial parameters using the bar coded setup menu or by the keypad in PROGRAMMING MODE. The serial default settings on the TriCoder are: 5-5
Page 43
Setup Parameter
Setting
Description
Computer Interface
3
Default setting on all T54/LT54s. RS232 ASCII Data Format –
Baud Rate
5
9600
Parity
0
None
Data Bits Stop Bits
1 0
8 bits 1 bit
Protocol
0
None
Default Serial Parameters Only the default settings for each Setup Parameter are shown above. See Chapter 6; TriCoder Setup for detailed information.
Testing Communication using NON PORTABLE mode Testing communication between a serial interface TriCoder and a PC needs some kind of software to read the serial port. If using a dumb terminal/host configuration, the testing is almost identical to that of a PC keyboard wedge. To establish communication between a serial TriCoder and its host, go to Chapter 3; Non Portable Mode for detailed instructions. The key to testing communications is to keep it simple – you don’t want to have to determine whether it’s your software or the TriCoder causing a problem.
Keyboard Wedge Interface (not USB) Connecting the Hardware The TriCoder can operate as a keyboard wedge on both a PC and a Macintosh. A simple cable and configuration change is all that is needed.
PC Keyboard Installation (does not apply to USB) To install the TriCoder as a keyboard wedge, use a Splitter cable, F30/1 for the PC. Use the following procedure and the diagram on the following page to install the TriCoder between the keyboard and computer: 1.
Before unplugging or plugging in anything, the computer must be turned OFF. With the power OFF, locate the cable coming out of the keyboard and follow it to the back of the computer where it plugs in. Unplug the keyboard cable, look at the connector and note whether it is large and has 5 pins or small with 6 pins. Take the F30-1 Y cable and check whether the female end of the cable matches (5 pin or 6 pin) the male end of the keyboard cable. If it does not, remove the adapter from the Splitter cable (it may be on either end), flip it over and place it on the correct end. You should now have the two ends of the Splitter cable and the keyboard cable all with the same size connector. 5-6
Page 44
2.
Take the end of the keyboard cable you unplugged from the back of the computer and plug it into the female end of the F30-1 Splitter cable. Take the male end of the F30-1 Splitter cable and plug it in to the back of the computer where the keyboard had been plugged in. The Splitter cable must sit in between the computer and the keyboard – do not plug the Splitter cable into a mouse port rd or any port other than the keyboard port. Take the 3 end of the Splitter cable with the modular (telephone style) connector and plug it into the port on the TriCoder labeled COMPUTER.
3.
Plug the 5-volt power adapter (included with the TriCoder) into the port labeled PWR at the bottom of the TriCoder. Turn the TriCoder on by pressing the ON/OFF key. Now turn on the computer. The TriCoder ships with a small black plastic block with a female modular connector in it called a Jumper Block. When removing the TriCoder from the cable for portable operation, place the Jumper Block on the now free end of the Splitter cable. This allows your keyboard to function even though the TriCoder is not attached.
PC Keyboard Wedge Installation
Configuring the TriCoder for Keyboard Wedge Once the hardware is connected, the next step is to configure the TriCoder and test your communication. The TriCoder setup allows the user to configure the TriCoder for different 5-7
Page 45
Computer Interfaces, and the reading of different bar code types, as well as configuring some of the more advanced features of the TriCoder. If you have a PC with a T64 or LT64 TriCoder, the default Computer Interface is 1- PC Keyboard.
Using the bar coded TriCoder Setup Menu To use the bar coded TriCoder Setup Menu, scan these bar codes in this order:
• • • •
Start Setup Setup Parameter bar code (i.e. “Beep Tone”) Number bar code that corresponds to the appropriate setting (i.e. “3” to change the Beep Tone to “high”) End Setup
More than one Setup Parameter can be changed before you scan END SETUP. For example, scan START SETUP, then “Beep Tone”, then 3, then “Operation Mode”, then 0, then END SETUP. This series of scans changes the beep tone to “high”, and puts the TriCoder into NON PORTABLE mode. For details on TriCoder Setup Parameters, see Chapter 6; TriCoder Setup. If you are using a Laser Scanner to setup the TriCoder, the beam will often cover more than one bar code. Cover any adjacent bar codes before scanning. Check the TriCoder display to make sure the correct setting was entered.
Using Programming Mode to change the TriCoder Setup The same Setup Parameters can be changed using the TriCoder keypad (no bar codes necessary) by going into PROGRAMMING MODE. Answer NO to all of the prompts until you see: PROGRAMMING MODE KEY [YES/NO]?_ Press the YES key, and then enter the password, WDTRI. At the menu prompt, press 5 to CHANGE SETUP. Once in the TriCoder Setup, press the number of the group you want to enter. Then press ENTER until you see the Setup Parameter you want to change (i.e. BEEP TONE), and then enter the number for the correct setting (i.e. 3 to change the BEEP TONE to “high”). To enter an alpha character (i.e. “A”), press the SHIFT key, and then press the corresponding alpha key (the alpha character is in the upper right corner of each key). You will know if the TriCoder is in “shifted” mode by the cursor – it will be a black square when shifted, a straight line when a narrow underline. More than one Setup Parameter can be changed before you exit the setup. Pressing F1 while in a Setup Parameter will take you back to the Setup Menu; from there choose a new group of settings. Pressing F1 again at the Setup Menu will exit PROGRAMMING MODE. 5-8
Page 46
Keyboard Interface Configuration For the last 5 years, all PCs use the same Computer Interface – the T64/LT64 TriCoder default setting of Computer Interface 1. Test scans with garbled or incomplete data not the result of the wrong interface, but rather are keyboard BIOS timing sensitivities. If you have garbled or incomplete data, try the “Learning” mode setting #8. “Learning” mode will make the correct adjustments for keyboard timing problems; see Chapter 6; TriCoder Setup: Computer Interface for details. To use the TriCoder as a Keyboard Interface, use the following chart to determine what the correct setup parameters are for the type of computer you are using: Computer Interface
PCs and Compatibles PC Learned timing
Setting
Description
1
Default Setting on T64/LT64. Used with all IBM PCs and compatibles unless you are choose a USB setting.
8
If you power the TriCoder with external power supply, you can use LEARNING mode. On the setup menu, scan START SETUP, Computer Interface, and then scan the 8. Press any key on the PC keyboard. (the TriCoder should beep once) then scan END SETUP. The TriCoder then watched the key codes coming from the PC and “learns” the timing, setting it in the EEPROM until you change it.
Testing Communication using NON PORTABLE mode To test communication as a keyboard wedge, go to Chapter 3; Non Portable Mode for detailed instruction on how to use NON PORTABLE mode to establish communication between the TriCoder and the host computer. The key to testing communications is to keep it simple – you don’t want to have to determine whether it’s your software or the TriCoder causing a problem.
5-9
Page 47
Page 48
Chapter 6
TriCoder Setup Most, but not all of the Setup Parameters can be changed by either using the TriCoder keypad in Programming Mode or scanning the appropriate bar codes on the TriCoder Setup Menu. You can also "clone" your setup from one TriCoder to another if you have the appropriate cables and if you are using high speed USB you can change your setup parameters using the TriCoder Utilities program.
Using the bar code TriCoder Setup Menu To access the Setup using the bar coded TriCoder Setup Menu, scan the START SETUP bar code in the upper left hand corner of the bar coded TriCoder Setup Menu. You should hear two beeps from the TriCoder upon scanning START SETUP and the words START SETUP should appear on the TriCoder display. At this point you are ready to scan and change as many parameters as you wish, following this order: 1. 2. 3.
4. 5. 6.
Scan the bar code for the parameter you want to change Scan the number on the Barpad Table (to the right) that corresponds to the setting you want to choose. If the parameter requires it, scan the SET bar code. SET is normally used to terminate a setup parameter that can have variable input, i.e. Preamble or Postamble. If you want to make more changes, go back and start at step 1 If you are finished, scan the END SETUP bar code in the upper right hand corner. You should hear 3 beeps at END SETUP. To reset the TriCoder back to the default settings at any time, scan START SETUP, RESET, then END SETUP. Resetting the TriCoder will lose any changes you have made and set the TriCoder to the default settings (indicated by a * on the bar coded setup menu).
Using the keypad to setup the TriCoder To use the keypad to setup the TriCoder, you must first get into PROGRAMMING MODE. To do this, answer NO to all Mode Menu prompts until you see: PROGRAMMING MODE KEY [YES/NO]?_ Press the YES key. A password is required to proceed into PROGRAMMING MODE: PROGRAMMING MODE PASSWORD?_ 6-1
Page 49
Enter the password, WDTRI using the TriCoder keypad, then press ENTER. The TriCoder now displays the PROGRAM FUNCTION menu: Create Programs->1-3 Voice Operations-->4 Change Setup------->5 Data File Names---->6 Press the 5 key to select Change Setup. The keypad setup menu is now displayed: BarCodes-->0 Computer->1 RS-232------>2 Security---->3
DateTime->4 Speaker--->5 Other------->6 Exit-------->F1
The setup parameters are distributed in the groups as follows: Menu
Setup
Selection
Parameters
Menu Selection
Setup Parameters
BAR CODES
Code 3 of 9
DATE TIME
Set Time
“0”
UPC & EAN
“4”
Set Date
Code 25 / I 25
Date Format
2 of 5 Length
Display of Year
Code 128 Codabar MSI/Plessey Code 93 COMPUTER
Computer Interface
SPEAKER
“1”
Intercharacter Delay
“5”
Terminator Character
Speaker /Batteries Beep Tone Speaker Volume
Beep Tone Single Cycle Transmit Country Code RS232
Baud Rate
OTHER
“2”
Protocol
“6”
Shut Down Time Preamble
Dialing String
Postamble
Parity
EOF String
Data Bits
Partitions
Stop Bits
Voice Messages
Set ID Character
Scanner Options
Host Response Delay
Aiming Dot Duration
Modem Redial Delay Transmit Mode SECURITY
Data Security
“3”
To select a particular category, press the corresponding number key on the 6-2
Page 50
TriCoder keypad. Once you are in a category, pressing ENTER will scroll through the parameters in the order shown above. When you get to the one you want to change, enter the new character (see the Parameter details later on), then press ENTER. Some changes must be made by scanning bar codes from the FULL ASCII MENU. You can set a parameter back to the default settings by pressing the CLEAR key. You can use the arrow keys to help you navigate the menu: Up Arrow moves to beginning of category
Down Arrow moves to end of category
Left Arrow moves up one in the category
Right Arrow moves down one in the category
Press the F1 key to go back to the category selection screen.
Using the TriCoder Utilities and USB to change Setup Parameters If you are using the High Speed USB interface, you can use the TriCoder Utilities program to change your setup parameters. To use the TriCoder Utilities, you must make sure your TriCoder is turned on, plugged into the USB cable and is set for High Speed USB interface. In the TriCoder Utilities program, choose Tools from the pull-down menu, and then choose TriCoder Setup.
6-3